Utilization of the Lower Inflection Point of the Pressure-Volume Curve Results In Protective Conventional Ventilation Comparable to High Frequency Oscillatory Ventilation in an Animal Model of Acute Respiratory Distress Syndrome

INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conv...

Descripción completa

Detalles Bibliográficos
Autores principales: Rossi, Felipe S., Mascaretti, Renata Suman, Haddad, Luciana B., Freddi, Norberto A., Mauad, Thais, Rebello, Celso M.
Formato: Texto
Lenguaje:English
Publicado: Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2664200/
https://www.ncbi.nlm.nih.gov/pubmed/18438579
_version_ 1782165946261045248
author Rossi, Felipe S.
Mascaretti, Renata Suman
Haddad, Luciana B.
Freddi, Norberto A.
Mauad, Thais
Rebello, Celso M.
author_facet Rossi, Felipe S.
Mascaretti, Renata Suman
Haddad, Luciana B.
Freddi, Norberto A.
Mauad, Thais
Rebello, Celso M.
author_sort Rossi, Felipe S.
collection PubMed
description INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume curve as the determinant of positive end-expiratory pressure to obtain similar levels of recruitment and alveolar stability. METHODS: After lung lavage of adult rabbits and lower inflection point determination, two groups were randomized: conventional (positive end-expiratory pressure = lower inflection point; tidal volume=6 ml/kg) and high frequency ventilation (mean airway pressures= lower inflection point +4 cmH(2)O). Blood gas and hemodynamic data were recorded over 4 h. After sacrifice, protein analysis from lung lavage and histologic evaluation were performed. RESULTS: The oxygenation parameters, protein and histological data were similar, except for the fact that significantly more normal alveoli were observed upon protective ventilation. High frequency ventilation led to lower PaCO(2) levels. DISCUSSION: Determination of the lower inflection point of the pressure-volume curve is important for setting the minimum end expiratory pressure needed to keep the airways opened. This is useful when comparing different strategies to treat severe respiratory insufficiency, optimizing conventional ventilation, improving oxygenation and reducing lung injury. CONCLUSIONS: Utilization of the lower inflection point of the pressure-volume curve in the ventilation strategies considered in this study resulted in comparable efficacy with regards to oxygenation and hemodynamics, a high PaCO(2) level and a lower pH. In addition, a greater number of normal alveoli were found after protective conventional ventilation in an animal model of acute respiratory distress syndrome.
format Text
id pubmed-2664200
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-26642002009-05-13 Utilization of the Lower Inflection Point of the Pressure-Volume Curve Results In Protective Conventional Ventilation Comparable to High Frequency Oscillatory Ventilation in an Animal Model of Acute Respiratory Distress Syndrome Rossi, Felipe S. Mascaretti, Renata Suman Haddad, Luciana B. Freddi, Norberto A. Mauad, Thais Rebello, Celso M. Clinics Basic Research INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume curve as the determinant of positive end-expiratory pressure to obtain similar levels of recruitment and alveolar stability. METHODS: After lung lavage of adult rabbits and lower inflection point determination, two groups were randomized: conventional (positive end-expiratory pressure = lower inflection point; tidal volume=6 ml/kg) and high frequency ventilation (mean airway pressures= lower inflection point +4 cmH(2)O). Blood gas and hemodynamic data were recorded over 4 h. After sacrifice, protein analysis from lung lavage and histologic evaluation were performed. RESULTS: The oxygenation parameters, protein and histological data were similar, except for the fact that significantly more normal alveoli were observed upon protective ventilation. High frequency ventilation led to lower PaCO(2) levels. DISCUSSION: Determination of the lower inflection point of the pressure-volume curve is important for setting the minimum end expiratory pressure needed to keep the airways opened. This is useful when comparing different strategies to treat severe respiratory insufficiency, optimizing conventional ventilation, improving oxygenation and reducing lung injury. CONCLUSIONS: Utilization of the lower inflection point of the pressure-volume curve in the ventilation strategies considered in this study resulted in comparable efficacy with regards to oxygenation and hemodynamics, a high PaCO(2) level and a lower pH. In addition, a greater number of normal alveoli were found after protective conventional ventilation in an animal model of acute respiratory distress syndrome. Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2008-04 /pmc/articles/PMC2664200/ /pubmed/18438579 Text en Copyright © 2008 Hospital das Clínicas da FMUSP
spellingShingle Basic Research
Rossi, Felipe S.
Mascaretti, Renata Suman
Haddad, Luciana B.
Freddi, Norberto A.
Mauad, Thais
Rebello, Celso M.
Utilization of the Lower Inflection Point of the Pressure-Volume Curve Results In Protective Conventional Ventilation Comparable to High Frequency Oscillatory Ventilation in an Animal Model of Acute Respiratory Distress Syndrome
title Utilization of the Lower Inflection Point of the Pressure-Volume Curve Results In Protective Conventional Ventilation Comparable to High Frequency Oscillatory Ventilation in an Animal Model of Acute Respiratory Distress Syndrome
title_full Utilization of the Lower Inflection Point of the Pressure-Volume Curve Results In Protective Conventional Ventilation Comparable to High Frequency Oscillatory Ventilation in an Animal Model of Acute Respiratory Distress Syndrome
title_fullStr Utilization of the Lower Inflection Point of the Pressure-Volume Curve Results In Protective Conventional Ventilation Comparable to High Frequency Oscillatory Ventilation in an Animal Model of Acute Respiratory Distress Syndrome
title_full_unstemmed Utilization of the Lower Inflection Point of the Pressure-Volume Curve Results In Protective Conventional Ventilation Comparable to High Frequency Oscillatory Ventilation in an Animal Model of Acute Respiratory Distress Syndrome
title_short Utilization of the Lower Inflection Point of the Pressure-Volume Curve Results In Protective Conventional Ventilation Comparable to High Frequency Oscillatory Ventilation in an Animal Model of Acute Respiratory Distress Syndrome
title_sort utilization of the lower inflection point of the pressure-volume curve results in protective conventional ventilation comparable to high frequency oscillatory ventilation in an animal model of acute respiratory distress syndrome
topic Basic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2664200/
https://www.ncbi.nlm.nih.gov/pubmed/18438579
work_keys_str_mv AT rossifelipes utilizationofthelowerinflectionpointofthepressurevolumecurveresultsinprotectiveconventionalventilationcomparabletohighfrequencyoscillatoryventilationinananimalmodelofacuterespiratorydistresssyndrome
AT mascarettirenatasuman utilizationofthelowerinflectionpointofthepressurevolumecurveresultsinprotectiveconventionalventilationcomparabletohighfrequencyoscillatoryventilationinananimalmodelofacuterespiratorydistresssyndrome
AT haddadlucianab utilizationofthelowerinflectionpointofthepressurevolumecurveresultsinprotectiveconventionalventilationcomparabletohighfrequencyoscillatoryventilationinananimalmodelofacuterespiratorydistresssyndrome
AT freddinorbertoa utilizationofthelowerinflectionpointofthepressurevolumecurveresultsinprotectiveconventionalventilationcomparabletohighfrequencyoscillatoryventilationinananimalmodelofacuterespiratorydistresssyndrome
AT mauadthais utilizationofthelowerinflectionpointofthepressurevolumecurveresultsinprotectiveconventionalventilationcomparabletohighfrequencyoscillatoryventilationinananimalmodelofacuterespiratorydistresssyndrome
AT rebellocelsom utilizationofthelowerinflectionpointofthepressurevolumecurveresultsinprotectiveconventionalventilationcomparabletohighfrequencyoscillatoryventilationinananimalmodelofacuterespiratorydistresssyndrome