Cargando…
Determining Plasma Morphine Levels Using Gc-Ms After Solid Phase Extraction to Monitor Drug Levels in the Postoperative Period
OBJECTIVE: To implement a selective and sensitive analytical method to quantify morphine in small volumes of plasma by gas-liquid chromatography-mass spectrometry (GC-MS), aimed at post-operatively monitoring the drug. METHOD: A gas-liquid chromatographic method with mass detection has been develope...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2664238/ https://www.ncbi.nlm.nih.gov/pubmed/18568238 http://dx.doi.org/10.1590/S1807-59322008000300004 |
Sumario: | OBJECTIVE: To implement a selective and sensitive analytical method to quantify morphine in small volumes of plasma by gas-liquid chromatography-mass spectrometry (GC-MS), aimed at post-operatively monitoring the drug. METHOD: A gas-liquid chromatographic method with mass detection has been developed to determine morphine concentration in plasma after solid phase extraction. Morphine-d3 was used as an internal standard. Only 0.5 mL of plasma is required for the drug solid-phase extraction in the Bond Elut-Certify(®), followed by the quantification of morphine derivative by GC-MS using a linear temperature program, a capillary fused silica column, and helium as the carrier and make-up gas. The method was applied to determine morphine content in plasma samples of four patients during the postoperative period of cardiac surgery. Patient-controlled analgesia with morphine was performed by a venous catheter, and a series of venous blood samples were collected. After the oro-tracheal extubation, morphine plasma levels were monitored for up to 36 hours. RESULTS: The run time was 16 minutes because morphine and the internal standard were eluted after 8.8 minutes. The GC-MS method had 0.5–1000 ng/mL linearity range (r(2)=0.9995), 0.1 ng/mL limit of detection, intraday and interday precision equivalent to 1.9% and 6.8%, and 0.1% and 0.8% systematic error (intraday and interday, respectively). The analytical method showed optimal absolute (98%) and relative (100.7%) recoveries. Morphine dose requirements and plasma levels are discussed. CONCLUSION: The analytical gas-liquid chromatography-mass spectrometry method is selective and adequate for morphine measurements in plasma for applications in clinical studies. |
---|