Cargando…

Interaction Between Intra-Abdominal Pressure and Positive-End Expiratory Pressure

OBJECTIVE: The aim of this study was to quantify the interaction between increased intra-abdominal pressure and Positive-End Expiratory Pressure. METHODS: In 30 mechanically ventilated ICU patients with a fixed tidal volume, respiratory system plateau and abdominal pressure were measured at a Positi...

Descripción completa

Detalles Bibliográficos
Autores principales: Torquato, Jamili Anbar, Lucato, Jeanette Janaina Jaber, Antunes, Telma, Barbas, Carmen Valente
Formato: Texto
Lenguaje:English
Publicado: Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2666478/
https://www.ncbi.nlm.nih.gov/pubmed/19219315
http://dx.doi.org/10.1590/S1807-59322009000200007
Descripción
Sumario:OBJECTIVE: The aim of this study was to quantify the interaction between increased intra-abdominal pressure and Positive-End Expiratory Pressure. METHODS: In 30 mechanically ventilated ICU patients with a fixed tidal volume, respiratory system plateau and abdominal pressure were measured at a Positive-End Expiratory Pressure level of zero and 10 cm H(2)O. The measurements were repeated after placing a 5 kg weight on the patients’ belly. RESULTS: After the addition of 5 kg to the patients’ belly at zero Positive-End Expiratory Pressure, both intra-abdominal pressure (p<0.001) and plateau pressures (p=0.005) increased significantly. Increasing the Positive-End Expiratory Pressure levels from zero to 10 cm H(2)O without weight on the belly did not result in any increase in intrazxabdominal pressure (p=0.165). However, plateau pressures increased significantly (p< 0.001). Increasing Positive-End Expiratory Pressure from zero to 10 cm H(2)O and adding 5 kg to the belly increased intra-abdominal pressure from 8.7 to 16.8 (p<0.001) and plateau pressure from 18.26 to 27.2 (p<0.001). Maintaining Positive-End Expiratory Pressure at 10 cmH(2)O and placing 5 kg on the belly increased intra-abdominal pressure from 12.3 +/− 1.7 to 16.8 +/− 1.7 (p<0.001) but did not increase plateau pressure (26.6+/−1.2 to 27.2 +/−1.1 −p=0.83). CONCLUSIONS: The addition of a 5kg weight onto the abdomen significantly increased both IAP and the airway plateau pressure, confirming that intra-abdominal hypertension elevates the plateau pressure. However, plateau pressure alone cannot be considered a good indicator for the detection of elevated intra-abdominal pressure in patients under mechanical ventilation using PEEP. In these patients, the intra-abdominal pressure must also be measured.