Cargando…

Aortic distensibility and coronary artery bypass graft patency

BACKGROUND: Aortic distensibility is an elasticity index of the aorta, and reflects aortic stiffness. Coronary artery disease has been found to be substantially associated with increased aortic stiffness. In this study we aimed to retrospectively analyze the association of angiographically determine...

Descripción completa

Detalles Bibliográficos
Autores principales: Özdemir, Bülent, Biçer, Murat, Özdemir, Levent, Baran, İbrahim, Kaderli, Aysel Aydın, Şentürk, Tunay, Emül, Ali, Yetgin, Zeynel Abidin, Güllülü, Sümeyye, Aydınlar, Ali
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2667388/
https://www.ncbi.nlm.nih.gov/pubmed/19323814
http://dx.doi.org/10.1186/1749-8090-4-14
_version_ 1782166116218437632
author Özdemir, Bülent
Biçer, Murat
Özdemir, Levent
Baran, İbrahim
Kaderli, Aysel Aydın
Şentürk, Tunay
Emül, Ali
Yetgin, Zeynel Abidin
Güllülü, Sümeyye
Aydınlar, Ali
author_facet Özdemir, Bülent
Biçer, Murat
Özdemir, Levent
Baran, İbrahim
Kaderli, Aysel Aydın
Şentürk, Tunay
Emül, Ali
Yetgin, Zeynel Abidin
Güllülü, Sümeyye
Aydınlar, Ali
author_sort Özdemir, Bülent
collection PubMed
description BACKGROUND: Aortic distensibility is an elasticity index of the aorta, and reflects aortic stiffness. Coronary artery disease has been found to be substantially associated with increased aortic stiffness. In this study we aimed to retrospectively analyze the association of angiographically determined aortic distensibility with the patency rates of coronary bypass grafts METHODS: The study was conducted in the Cardiology department of the Applied Research Centre for Health of Uludağ University. The coronary angiograms of 53 consecutive coronary bypass patients were analysed retrospectively. Aortic distensibility was calculated using the formula: 2 × (change in aortic diameter)/(diastolic aortic diameter) × (change in aortic pressure). The number of stenosed and patent bypass grafts and the patient characteristics like age, risk factors were noted. RESULTS: There were 44 male (83%) and 9 female (17%) cases. Eighteen cases had only one saphenous vein grafting. The number of cases with two, three and four saphenous grafting were 18, 11 and 1; respectively. In the control angiograms the number of cases with one, two, three and four saphenous vein graft obstruction were 15 (31.3%), 7 (14.6%), 1 (2.1%) and 1 (2.1%) respectively. The aortic distensibility did not differ in cases with and without saphenous graft occlusion (p > 0.05). Also left internal mammary artery (LIMA) graft patency was not related to the distensibility of the aorta (p > 0.05). We also evaluated the data for cut-off values of 50 and 70 mmHg of pulse pressure and did not see any significant difference between the groups in terms of saphenous or LIMA grafts. CONCLUSION: In this study we failed to show association of angiographically determined aortic distensibility with coronary bypass graft patency in consecutive 53 patients with coronary artery bypass graft surgery (CABG).
format Text
id pubmed-2667388
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-26673882009-04-10 Aortic distensibility and coronary artery bypass graft patency Özdemir, Bülent Biçer, Murat Özdemir, Levent Baran, İbrahim Kaderli, Aysel Aydın Şentürk, Tunay Emül, Ali Yetgin, Zeynel Abidin Güllülü, Sümeyye Aydınlar, Ali J Cardiothorac Surg Research Article BACKGROUND: Aortic distensibility is an elasticity index of the aorta, and reflects aortic stiffness. Coronary artery disease has been found to be substantially associated with increased aortic stiffness. In this study we aimed to retrospectively analyze the association of angiographically determined aortic distensibility with the patency rates of coronary bypass grafts METHODS: The study was conducted in the Cardiology department of the Applied Research Centre for Health of Uludağ University. The coronary angiograms of 53 consecutive coronary bypass patients were analysed retrospectively. Aortic distensibility was calculated using the formula: 2 × (change in aortic diameter)/(diastolic aortic diameter) × (change in aortic pressure). The number of stenosed and patent bypass grafts and the patient characteristics like age, risk factors were noted. RESULTS: There were 44 male (83%) and 9 female (17%) cases. Eighteen cases had only one saphenous vein grafting. The number of cases with two, three and four saphenous grafting were 18, 11 and 1; respectively. In the control angiograms the number of cases with one, two, three and four saphenous vein graft obstruction were 15 (31.3%), 7 (14.6%), 1 (2.1%) and 1 (2.1%) respectively. The aortic distensibility did not differ in cases with and without saphenous graft occlusion (p > 0.05). Also left internal mammary artery (LIMA) graft patency was not related to the distensibility of the aorta (p > 0.05). We also evaluated the data for cut-off values of 50 and 70 mmHg of pulse pressure and did not see any significant difference between the groups in terms of saphenous or LIMA grafts. CONCLUSION: In this study we failed to show association of angiographically determined aortic distensibility with coronary bypass graft patency in consecutive 53 patients with coronary artery bypass graft surgery (CABG). BioMed Central 2009-03-26 /pmc/articles/PMC2667388/ /pubmed/19323814 http://dx.doi.org/10.1186/1749-8090-4-14 Text en Copyright © 2009 Özdemir et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Özdemir, Bülent
Biçer, Murat
Özdemir, Levent
Baran, İbrahim
Kaderli, Aysel Aydın
Şentürk, Tunay
Emül, Ali
Yetgin, Zeynel Abidin
Güllülü, Sümeyye
Aydınlar, Ali
Aortic distensibility and coronary artery bypass graft patency
title Aortic distensibility and coronary artery bypass graft patency
title_full Aortic distensibility and coronary artery bypass graft patency
title_fullStr Aortic distensibility and coronary artery bypass graft patency
title_full_unstemmed Aortic distensibility and coronary artery bypass graft patency
title_short Aortic distensibility and coronary artery bypass graft patency
title_sort aortic distensibility and coronary artery bypass graft patency
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2667388/
https://www.ncbi.nlm.nih.gov/pubmed/19323814
http://dx.doi.org/10.1186/1749-8090-4-14
work_keys_str_mv AT ozdemirbulent aorticdistensibilityandcoronaryarterybypassgraftpatency
AT bicermurat aorticdistensibilityandcoronaryarterybypassgraftpatency
AT ozdemirlevent aorticdistensibilityandcoronaryarterybypassgraftpatency
AT baranibrahim aorticdistensibilityandcoronaryarterybypassgraftpatency
AT kaderliayselaydın aorticdistensibilityandcoronaryarterybypassgraftpatency
AT senturktunay aorticdistensibilityandcoronaryarterybypassgraftpatency
AT emulali aorticdistensibilityandcoronaryarterybypassgraftpatency
AT yetginzeynelabidin aorticdistensibilityandcoronaryarterybypassgraftpatency
AT gullulusumeyye aorticdistensibilityandcoronaryarterybypassgraftpatency
AT aydınlarali aorticdistensibilityandcoronaryarterybypassgraftpatency