Cargando…
Comparison of a Two-Lead, Computerized, Resting ECG Signal Analysis Device, the MultiFunction-CardioGram(sm) or MCG (a.k.a. 3DMP), to Quantitative Coronary Angiography for the Detection of Relevant Coronary Artery Stenosis (>70%) - A Meta-Analysis of all Published Trials Performed and Analyzed in the US
Background: Accurate, non-invasive diagnosis of, and screening for, coronary artery disease (CAD) and restenosis after coronary revascularization has been a challenge due to either low sensitivity/specificity or relevant morbidity associated with current diagnostic modalities. Methods: To assess sen...
Autores principales: | , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Ivyspring International Publisher
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2669600/ https://www.ncbi.nlm.nih.gov/pubmed/19381351 |
_version_ | 1782166269688020992 |
---|---|
author | Strobeck, John E. Shen, Joseph T. Singh, Binoy Obunai, Kotaro Miceli, Charles Sacher, Howard Ritucci, Franz Imhoff, Michael |
author_facet | Strobeck, John E. Shen, Joseph T. Singh, Binoy Obunai, Kotaro Miceli, Charles Sacher, Howard Ritucci, Franz Imhoff, Michael |
author_sort | Strobeck, John E. |
collection | PubMed |
description | Background: Accurate, non-invasive diagnosis of, and screening for, coronary artery disease (CAD) and restenosis after coronary revascularization has been a challenge due to either low sensitivity/specificity or relevant morbidity associated with current diagnostic modalities. Methods: To assess sensitivity and specificity of a new computerized, multiphase, resting electrocardiogram analysis device (MultiFunction-CardioGram(sm) or MCG a.k.a. 3DMP) for the detection of relevant coronary stenosis (>70%), a meta-analysis of three published prospective trials performed in the US on patient data collected using the US manufactured device and analyzed using the US-based software and New York data analysis center from patients in the US, Germany, and Asia was completed. A total of 1076 patients from the three trials (US - 136; Germany - 751; Asia - 189) (average age 62 ± 11.5, 65 for women, 60 for men) scheduled for coronary angiography, were included in the analysis. Patients enrolled in the trials may or may not have had prior angiography and/or coronary intervention. Angiographic results in all studies were classified for hemodynamically relevant stenosis (> 70%) by two US based angiographers independently. Results: Hemodynamically relevant stenosis was diagnosed in 467 patients (43.4%). The device, after performing a frequency-domain, computational analysis of the resting ECG leads and computer-database comparison, calculated a coronary ischemia “severity” score from 0 to 20 for each patient. The severity score was significantly higher for patients with relevant coronary stenosis (5.4 ± 1.8 vs. 1.7 ± 2.1). The study device (using a cut-off score for relevant stenosis of 4.0) correctly classified 941 of the 1076 patients with or without relevant stenosis (sensitivity-91.2%; specificity-84.6%; NPV 0.942, PPV 0.777). Adjusted positive and negative predictive values (PPV and NPV) were 81.9% and 92.6%, respectively (ROC AUC = 0.881 [95% CI: 0.860-0.903]). Subgroup analysis showed no significant influence of sex, age, race/nationality, previous revascularization procedures, resting ECG morphology, or participating center on the device's diagnostic performance. Conclusions: The new computerized, multiphase, resting ECG analysis device (MultiFunction-CardioGram(sm)) has been shown in this meta-analysis to safely and accurately identify patients with relevant coronary stenosis (>70%) with high sensitivity and specificity and high negative predictive value. Its potential use in the evaluation of symptomatic patients suspected to suffer from coronary disease/ischemia is discussed. |
format | Text |
id | pubmed-2669600 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Ivyspring International Publisher |
record_format | MEDLINE/PubMed |
spelling | pubmed-26696002009-04-16 Comparison of a Two-Lead, Computerized, Resting ECG Signal Analysis Device, the MultiFunction-CardioGram(sm) or MCG (a.k.a. 3DMP), to Quantitative Coronary Angiography for the Detection of Relevant Coronary Artery Stenosis (>70%) - A Meta-Analysis of all Published Trials Performed and Analyzed in the US Strobeck, John E. Shen, Joseph T. Singh, Binoy Obunai, Kotaro Miceli, Charles Sacher, Howard Ritucci, Franz Imhoff, Michael Int J Med Sci Research Paper Background: Accurate, non-invasive diagnosis of, and screening for, coronary artery disease (CAD) and restenosis after coronary revascularization has been a challenge due to either low sensitivity/specificity or relevant morbidity associated with current diagnostic modalities. Methods: To assess sensitivity and specificity of a new computerized, multiphase, resting electrocardiogram analysis device (MultiFunction-CardioGram(sm) or MCG a.k.a. 3DMP) for the detection of relevant coronary stenosis (>70%), a meta-analysis of three published prospective trials performed in the US on patient data collected using the US manufactured device and analyzed using the US-based software and New York data analysis center from patients in the US, Germany, and Asia was completed. A total of 1076 patients from the three trials (US - 136; Germany - 751; Asia - 189) (average age 62 ± 11.5, 65 for women, 60 for men) scheduled for coronary angiography, were included in the analysis. Patients enrolled in the trials may or may not have had prior angiography and/or coronary intervention. Angiographic results in all studies were classified for hemodynamically relevant stenosis (> 70%) by two US based angiographers independently. Results: Hemodynamically relevant stenosis was diagnosed in 467 patients (43.4%). The device, after performing a frequency-domain, computational analysis of the resting ECG leads and computer-database comparison, calculated a coronary ischemia “severity” score from 0 to 20 for each patient. The severity score was significantly higher for patients with relevant coronary stenosis (5.4 ± 1.8 vs. 1.7 ± 2.1). The study device (using a cut-off score for relevant stenosis of 4.0) correctly classified 941 of the 1076 patients with or without relevant stenosis (sensitivity-91.2%; specificity-84.6%; NPV 0.942, PPV 0.777). Adjusted positive and negative predictive values (PPV and NPV) were 81.9% and 92.6%, respectively (ROC AUC = 0.881 [95% CI: 0.860-0.903]). Subgroup analysis showed no significant influence of sex, age, race/nationality, previous revascularization procedures, resting ECG morphology, or participating center on the device's diagnostic performance. Conclusions: The new computerized, multiphase, resting ECG analysis device (MultiFunction-CardioGram(sm)) has been shown in this meta-analysis to safely and accurately identify patients with relevant coronary stenosis (>70%) with high sensitivity and specificity and high negative predictive value. Its potential use in the evaluation of symptomatic patients suspected to suffer from coronary disease/ischemia is discussed. Ivyspring International Publisher 2009-04-07 /pmc/articles/PMC2669600/ /pubmed/19381351 Text en © Ivyspring International Publisher. This is an open-access article distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by-nc-nd/3.0/). Reproduction is permitted for personal, noncommercial use, provided that the article is in whole, unmodified, and properly cited. |
spellingShingle | Research Paper Strobeck, John E. Shen, Joseph T. Singh, Binoy Obunai, Kotaro Miceli, Charles Sacher, Howard Ritucci, Franz Imhoff, Michael Comparison of a Two-Lead, Computerized, Resting ECG Signal Analysis Device, the MultiFunction-CardioGram(sm) or MCG (a.k.a. 3DMP), to Quantitative Coronary Angiography for the Detection of Relevant Coronary Artery Stenosis (>70%) - A Meta-Analysis of all Published Trials Performed and Analyzed in the US |
title | Comparison of a Two-Lead, Computerized, Resting ECG Signal Analysis Device, the MultiFunction-CardioGram(sm) or MCG (a.k.a. 3DMP), to Quantitative Coronary Angiography for the Detection of Relevant Coronary Artery Stenosis (>70%) - A Meta-Analysis of all Published Trials Performed and Analyzed in the US |
title_full | Comparison of a Two-Lead, Computerized, Resting ECG Signal Analysis Device, the MultiFunction-CardioGram(sm) or MCG (a.k.a. 3DMP), to Quantitative Coronary Angiography for the Detection of Relevant Coronary Artery Stenosis (>70%) - A Meta-Analysis of all Published Trials Performed and Analyzed in the US |
title_fullStr | Comparison of a Two-Lead, Computerized, Resting ECG Signal Analysis Device, the MultiFunction-CardioGram(sm) or MCG (a.k.a. 3DMP), to Quantitative Coronary Angiography for the Detection of Relevant Coronary Artery Stenosis (>70%) - A Meta-Analysis of all Published Trials Performed and Analyzed in the US |
title_full_unstemmed | Comparison of a Two-Lead, Computerized, Resting ECG Signal Analysis Device, the MultiFunction-CardioGram(sm) or MCG (a.k.a. 3DMP), to Quantitative Coronary Angiography for the Detection of Relevant Coronary Artery Stenosis (>70%) - A Meta-Analysis of all Published Trials Performed and Analyzed in the US |
title_short | Comparison of a Two-Lead, Computerized, Resting ECG Signal Analysis Device, the MultiFunction-CardioGram(sm) or MCG (a.k.a. 3DMP), to Quantitative Coronary Angiography for the Detection of Relevant Coronary Artery Stenosis (>70%) - A Meta-Analysis of all Published Trials Performed and Analyzed in the US |
title_sort | comparison of a two-lead, computerized, resting ecg signal analysis device, the multifunction-cardiogram(sm) or mcg (a.k.a. 3dmp), to quantitative coronary angiography for the detection of relevant coronary artery stenosis (>70%) - a meta-analysis of all published trials performed and analyzed in the us |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2669600/ https://www.ncbi.nlm.nih.gov/pubmed/19381351 |
work_keys_str_mv | AT strobeckjohne comparisonofatwoleadcomputerizedrestingecgsignalanalysisdevicethemultifunctioncardiogramsmormcgaka3dmptoquantitativecoronaryangiographyforthedetectionofrelevantcoronaryarterystenosis70ametaanalysisofallpublishedtrialsperformedandanalyzedintheus AT shenjosepht comparisonofatwoleadcomputerizedrestingecgsignalanalysisdevicethemultifunctioncardiogramsmormcgaka3dmptoquantitativecoronaryangiographyforthedetectionofrelevantcoronaryarterystenosis70ametaanalysisofallpublishedtrialsperformedandanalyzedintheus AT singhbinoy comparisonofatwoleadcomputerizedrestingecgsignalanalysisdevicethemultifunctioncardiogramsmormcgaka3dmptoquantitativecoronaryangiographyforthedetectionofrelevantcoronaryarterystenosis70ametaanalysisofallpublishedtrialsperformedandanalyzedintheus AT obunaikotaro comparisonofatwoleadcomputerizedrestingecgsignalanalysisdevicethemultifunctioncardiogramsmormcgaka3dmptoquantitativecoronaryangiographyforthedetectionofrelevantcoronaryarterystenosis70ametaanalysisofallpublishedtrialsperformedandanalyzedintheus AT micelicharles comparisonofatwoleadcomputerizedrestingecgsignalanalysisdevicethemultifunctioncardiogramsmormcgaka3dmptoquantitativecoronaryangiographyforthedetectionofrelevantcoronaryarterystenosis70ametaanalysisofallpublishedtrialsperformedandanalyzedintheus AT sacherhoward comparisonofatwoleadcomputerizedrestingecgsignalanalysisdevicethemultifunctioncardiogramsmormcgaka3dmptoquantitativecoronaryangiographyforthedetectionofrelevantcoronaryarterystenosis70ametaanalysisofallpublishedtrialsperformedandanalyzedintheus AT rituccifranz comparisonofatwoleadcomputerizedrestingecgsignalanalysisdevicethemultifunctioncardiogramsmormcgaka3dmptoquantitativecoronaryangiographyforthedetectionofrelevantcoronaryarterystenosis70ametaanalysisofallpublishedtrialsperformedandanalyzedintheus AT imhoffmichael comparisonofatwoleadcomputerizedrestingecgsignalanalysisdevicethemultifunctioncardiogramsmormcgaka3dmptoquantitativecoronaryangiographyforthedetectionofrelevantcoronaryarterystenosis70ametaanalysisofallpublishedtrialsperformedandanalyzedintheus |