Cargando…
Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation
BACKGROUND: Safe and effective colonoscopy is aided by the use of endoscopic techniques and maneuvers (ETM) during the examination including patient repositioning, stiffening of the endoscope and abdominal pressure. AIM: To better understand the use and value of ETM during colonoscopy by using a dev...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2670842/ https://www.ncbi.nlm.nih.gov/pubmed/19358723 http://dx.doi.org/10.1186/1471-230X-9-24 |
_version_ | 1782166329985335296 |
---|---|
author | Heigh, Russell I DiBaise, John K Prechel, James A Horn, Billie J San Miguel, Sarah Heigh, Evelyn G Leighton, Jonathan A Edgelow, Cynthia J Fleischer, David E |
author_facet | Heigh, Russell I DiBaise, John K Prechel, James A Horn, Billie J San Miguel, Sarah Heigh, Evelyn G Leighton, Jonathan A Edgelow, Cynthia J Fleischer, David E |
author_sort | Heigh, Russell I |
collection | PubMed |
description | BACKGROUND: Safe and effective colonoscopy is aided by the use of endoscopic techniques and maneuvers (ETM) during the examination including patient repositioning, stiffening of the endoscope and abdominal pressure. AIM: To better understand the use and value of ETM during colonoscopy by using a device that allows real-time imaging of the colonoscope insertion shaft. METHODS: The use of ETM during colonoscopy and their success was recorded. Experienced colonoscopists and endoscopy assistants used a commercially available electromagnetic (EM) transmitter and a special adult variable stiffness instrument with 12 embedded sensors to examine 46 patients. In 5 of these a special EM probe passed through the instrument channel of a standard pediatric variable stiffness colonoscope was used instead of the EM colonoscope. RESULTS: Thirty-nine men and 7 women with a mean age of 64 years (range 33–90) were studied. The cecum was intubated in 93.5% (43/46). The mean time to reach the cecum was 10.6 minutes (range 3–25). ETM were used a total of 174 times in 41 of the patients to assist with cecal intubation. When ETM were required to reach the cecum, and the cecum was intubated, an average of 3.82 ETM/patient was used. While ETM were used most often when the tip of the colonoscope was in the left side of the colon (rectum 5.0%, sigmoid colon 20.7%, descending colon 5.0%, and splenic flexure 11.6%), when the instrument was in the transverse colon (14.8%), hepatic flexure (20.7%) and ascending colon (19.8%) the use of ETM was also required. When the colonoscope tip was in the transverse colon, hepatic flexure and ascending colon, ETM success rates were less (61.1%, 52.0%, and 41.7% respectively) compared to the left colon success rates (rectum 83.3%, sigmoid colon 84.0%, descending colon 100%, and splenic flexure 85.7%). CONCLUSION: The EM colonoscope allows imaging of the insertion shaft without fluoroscopy and is a useful device for evaluating the efficacy of ETM. ETM are important tools of the colonoscopist and are used most often in the left colon where they are most effective. |
format | Text |
id | pubmed-2670842 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-26708422009-04-21 Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation Heigh, Russell I DiBaise, John K Prechel, James A Horn, Billie J San Miguel, Sarah Heigh, Evelyn G Leighton, Jonathan A Edgelow, Cynthia J Fleischer, David E BMC Gastroenterol Research Article BACKGROUND: Safe and effective colonoscopy is aided by the use of endoscopic techniques and maneuvers (ETM) during the examination including patient repositioning, stiffening of the endoscope and abdominal pressure. AIM: To better understand the use and value of ETM during colonoscopy by using a device that allows real-time imaging of the colonoscope insertion shaft. METHODS: The use of ETM during colonoscopy and their success was recorded. Experienced colonoscopists and endoscopy assistants used a commercially available electromagnetic (EM) transmitter and a special adult variable stiffness instrument with 12 embedded sensors to examine 46 patients. In 5 of these a special EM probe passed through the instrument channel of a standard pediatric variable stiffness colonoscope was used instead of the EM colonoscope. RESULTS: Thirty-nine men and 7 women with a mean age of 64 years (range 33–90) were studied. The cecum was intubated in 93.5% (43/46). The mean time to reach the cecum was 10.6 minutes (range 3–25). ETM were used a total of 174 times in 41 of the patients to assist with cecal intubation. When ETM were required to reach the cecum, and the cecum was intubated, an average of 3.82 ETM/patient was used. While ETM were used most often when the tip of the colonoscope was in the left side of the colon (rectum 5.0%, sigmoid colon 20.7%, descending colon 5.0%, and splenic flexure 11.6%), when the instrument was in the transverse colon (14.8%), hepatic flexure (20.7%) and ascending colon (19.8%) the use of ETM was also required. When the colonoscope tip was in the transverse colon, hepatic flexure and ascending colon, ETM success rates were less (61.1%, 52.0%, and 41.7% respectively) compared to the left colon success rates (rectum 83.3%, sigmoid colon 84.0%, descending colon 100%, and splenic flexure 85.7%). CONCLUSION: The EM colonoscope allows imaging of the insertion shaft without fluoroscopy and is a useful device for evaluating the efficacy of ETM. ETM are important tools of the colonoscopist and are used most often in the left colon where they are most effective. BioMed Central 2009-04-09 /pmc/articles/PMC2670842/ /pubmed/19358723 http://dx.doi.org/10.1186/1471-230X-9-24 Text en Copyright ©2009 Heigh et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Heigh, Russell I DiBaise, John K Prechel, James A Horn, Billie J San Miguel, Sarah Heigh, Evelyn G Leighton, Jonathan A Edgelow, Cynthia J Fleischer, David E Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation |
title | Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation |
title_full | Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation |
title_fullStr | Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation |
title_full_unstemmed | Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation |
title_short | Use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation |
title_sort | use of an electromagnetic colonoscope to assess maneuvers associated with cecal intubation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2670842/ https://www.ncbi.nlm.nih.gov/pubmed/19358723 http://dx.doi.org/10.1186/1471-230X-9-24 |
work_keys_str_mv | AT heighrusselli useofanelectromagneticcolonoscopetoassessmaneuversassociatedwithcecalintubation AT dibaisejohnk useofanelectromagneticcolonoscopetoassessmaneuversassociatedwithcecalintubation AT precheljamesa useofanelectromagneticcolonoscopetoassessmaneuversassociatedwithcecalintubation AT hornbilliej useofanelectromagneticcolonoscopetoassessmaneuversassociatedwithcecalintubation AT sanmiguelsarah useofanelectromagneticcolonoscopetoassessmaneuversassociatedwithcecalintubation AT heighevelyng useofanelectromagneticcolonoscopetoassessmaneuversassociatedwithcecalintubation AT leightonjonathana useofanelectromagneticcolonoscopetoassessmaneuversassociatedwithcecalintubation AT edgelowcynthiaj useofanelectromagneticcolonoscopetoassessmaneuversassociatedwithcecalintubation AT fleischerdavide useofanelectromagneticcolonoscopetoassessmaneuversassociatedwithcecalintubation |