The Influence of Reconstruction Algorithm and Heart Rate on Coronary Artery Image Quality and Stenosis Detection at 64-Detector Cardiac CT
OBJECTIVE: We wanted to evaluate the impact of two reconstruction algorithms (halfscan and multisector) on the image quality and the accuracy of measuring the severity of coronary stenoses by using a pulsating cardiac phantom with different heart rates (HRs). MATERIALS AND METHODS: Simulated coronar...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2672177/ https://www.ncbi.nlm.nih.gov/pubmed/19412510 http://dx.doi.org/10.3348/kjr.2009.10.3.227 |
_version_ | 1782166488027758592 |
---|---|
author | Wang, Yi-Ting Yang, Chung-Yi Hsiao, Jong-Kai Liu, Hon-Man Lee, Wen-Jen Shen, Yun |
author_facet | Wang, Yi-Ting Yang, Chung-Yi Hsiao, Jong-Kai Liu, Hon-Man Lee, Wen-Jen Shen, Yun |
author_sort | Wang, Yi-Ting |
collection | PubMed |
description | OBJECTIVE: We wanted to evaluate the impact of two reconstruction algorithms (halfscan and multisector) on the image quality and the accuracy of measuring the severity of coronary stenoses by using a pulsating cardiac phantom with different heart rates (HRs). MATERIALS AND METHODS: Simulated coronary arteries with different stenotic severities (25, 50, 75%) and different luminal diameters (3, 4, 5 mm) were scanned with a fixed pitch of 0.16 and a 0.35 second gantry rotation time on a 64-slice multidetector CT. Both reconstruction algorithms (halfscan and multisector) were applied to HRs of 40-120 beats per minute (bpm) at 10 bpm intervals. Three experienced radiologists visually assessed the image quality and they manually measured the stenotic severity. RESULTS: Fewer measurement errors occurred with multisector reconstruction (p = 0.05), a slower HR (p < 0.001) and a larger luminal diameter (p = 0.014); measurement errors were not related with the observers or the stenotic severity. There was no significant difference in measurements as for the reconstruction algorithms below an HR of 70 bpm. More nonassessable segments were visualized with halfscan reconstruction (p = 0.004) and higher HRs (p < 0.001). Halfscan reconstruction had better quality scores when the HR was below 60 bpm, while multisector reconstruction had better quality scores when the HR was above 90 bpm. For the HRs between 60 and 90 bpm, both reconstruction modes had similar quality scores. With excluding the nonassessable segments, both reconstruction algorithms achieved a similar mean measured stenotic severity and similar standard deviations. CONCLUSION: At a higher HR (above 90 bpm), multisector reconstruction had better temporal resolution, fewer nonassessable segments, better quality scores and better accuracy of measuring the stenotic severity in this phantom study. |
format | Text |
id | pubmed-2672177 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-26721772009-05-01 The Influence of Reconstruction Algorithm and Heart Rate on Coronary Artery Image Quality and Stenosis Detection at 64-Detector Cardiac CT Wang, Yi-Ting Yang, Chung-Yi Hsiao, Jong-Kai Liu, Hon-Man Lee, Wen-Jen Shen, Yun Korean J Radiol Original Article OBJECTIVE: We wanted to evaluate the impact of two reconstruction algorithms (halfscan and multisector) on the image quality and the accuracy of measuring the severity of coronary stenoses by using a pulsating cardiac phantom with different heart rates (HRs). MATERIALS AND METHODS: Simulated coronary arteries with different stenotic severities (25, 50, 75%) and different luminal diameters (3, 4, 5 mm) were scanned with a fixed pitch of 0.16 and a 0.35 second gantry rotation time on a 64-slice multidetector CT. Both reconstruction algorithms (halfscan and multisector) were applied to HRs of 40-120 beats per minute (bpm) at 10 bpm intervals. Three experienced radiologists visually assessed the image quality and they manually measured the stenotic severity. RESULTS: Fewer measurement errors occurred with multisector reconstruction (p = 0.05), a slower HR (p < 0.001) and a larger luminal diameter (p = 0.014); measurement errors were not related with the observers or the stenotic severity. There was no significant difference in measurements as for the reconstruction algorithms below an HR of 70 bpm. More nonassessable segments were visualized with halfscan reconstruction (p = 0.004) and higher HRs (p < 0.001). Halfscan reconstruction had better quality scores when the HR was below 60 bpm, while multisector reconstruction had better quality scores when the HR was above 90 bpm. For the HRs between 60 and 90 bpm, both reconstruction modes had similar quality scores. With excluding the nonassessable segments, both reconstruction algorithms achieved a similar mean measured stenotic severity and similar standard deviations. CONCLUSION: At a higher HR (above 90 bpm), multisector reconstruction had better temporal resolution, fewer nonassessable segments, better quality scores and better accuracy of measuring the stenotic severity in this phantom study. The Korean Society of Radiology 2009 2009-04-22 /pmc/articles/PMC2672177/ /pubmed/19412510 http://dx.doi.org/10.3348/kjr.2009.10.3.227 Text en Copyright © 2009 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Wang, Yi-Ting Yang, Chung-Yi Hsiao, Jong-Kai Liu, Hon-Man Lee, Wen-Jen Shen, Yun The Influence of Reconstruction Algorithm and Heart Rate on Coronary Artery Image Quality and Stenosis Detection at 64-Detector Cardiac CT |
title | The Influence of Reconstruction Algorithm and Heart Rate on Coronary Artery Image Quality and Stenosis Detection at 64-Detector Cardiac CT |
title_full | The Influence of Reconstruction Algorithm and Heart Rate on Coronary Artery Image Quality and Stenosis Detection at 64-Detector Cardiac CT |
title_fullStr | The Influence of Reconstruction Algorithm and Heart Rate on Coronary Artery Image Quality and Stenosis Detection at 64-Detector Cardiac CT |
title_full_unstemmed | The Influence of Reconstruction Algorithm and Heart Rate on Coronary Artery Image Quality and Stenosis Detection at 64-Detector Cardiac CT |
title_short | The Influence of Reconstruction Algorithm and Heart Rate on Coronary Artery Image Quality and Stenosis Detection at 64-Detector Cardiac CT |
title_sort | influence of reconstruction algorithm and heart rate on coronary artery image quality and stenosis detection at 64-detector cardiac ct |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2672177/ https://www.ncbi.nlm.nih.gov/pubmed/19412510 http://dx.doi.org/10.3348/kjr.2009.10.3.227 |
work_keys_str_mv | AT wangyiting theinfluenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT yangchungyi theinfluenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT hsiaojongkai theinfluenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT liuhonman theinfluenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT leewenjen theinfluenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT shenyun theinfluenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT wangyiting influenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT yangchungyi influenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT hsiaojongkai influenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT liuhonman influenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT leewenjen influenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct AT shenyun influenceofreconstructionalgorithmandheartrateoncoronaryarteryimagequalityandstenosisdetectionat64detectorcardiacct |