Cargando…

Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments

BACKGROUND: Efficient and safe transection of biological tissue in liver surgery is strongly dependent on the ability to address both parenchymal division and hemostasis simultaneously. In addition to the conventional clamp crushing or finger fracture methods other techniques based on radiofrequency...

Descripción completa

Detalles Bibliográficos
Autores principales: Burdío, Fernando, Berjano, Enrique J, Navarro, Ana, Burdío, José M, Grande, Luis, Gonzalez, Ana, Cruz, Ignacio, Güemes, Antonio, Sousa, Ramón, Subirá, Jorge, Castiella, Tomás, Poves, Ignasi, Lequerica, Juan L
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2672929/
https://www.ncbi.nlm.nih.gov/pubmed/19296852
http://dx.doi.org/10.1186/1475-925X-8-6
_version_ 1782166556580511744
author Burdío, Fernando
Berjano, Enrique J
Navarro, Ana
Burdío, José M
Grande, Luis
Gonzalez, Ana
Cruz, Ignacio
Güemes, Antonio
Sousa, Ramón
Subirá, Jorge
Castiella, Tomás
Poves, Ignasi
Lequerica, Juan L
author_facet Burdío, Fernando
Berjano, Enrique J
Navarro, Ana
Burdío, José M
Grande, Luis
Gonzalez, Ana
Cruz, Ignacio
Güemes, Antonio
Sousa, Ramón
Subirá, Jorge
Castiella, Tomás
Poves, Ignasi
Lequerica, Juan L
author_sort Burdío, Fernando
collection PubMed
description BACKGROUND: Efficient and safe transection of biological tissue in liver surgery is strongly dependent on the ability to address both parenchymal division and hemostasis simultaneously. In addition to the conventional clamp crushing or finger fracture methods other techniques based on radiofrequency (RF) currents have been extensively employed to reduce intraoperative blood loss. In this paper we present our broad research plan for a new RF-assisted device for bloodless, rapid resection of the liver. METHODS: Our research plan includes computer modeling and in vivo studies. Computer modeling was based on the Finite Element Method (FEM) and allowed us to estimate the distribution of electrical power deposited in the tissue, along with assessing the effect of the characteristics of the device on the temperature profiles. Studies based on in vivo pig liver models provided a comparison of the performance of the new device with other techniques (saline-linked technology) currently employed in clinical practice. Finally, the plan includes a pilot clinical trial, in which both the new device and the accessory equipment are seen to comply with all safety requirements. RESULTS: The FEM results showed a high electrical gradient around the tip of the blade, responsible for the maximal increase of temperature at that point, where temperature reached 100°C in only 3.85 s. Other hot points with lower temperatures were located at the proximal edge of the device. Additional simulations with an electrically insulated blade produced more uniform and larger lesions (assessed as the 55°C isotherm) than the electrically conducting blade. The in vivo study, in turn, showed greater transection speed (3 ± 0 and 3 ± 1 cm(2)/min for the new device in the open and laparoscopic approaches respectively) and also lower blood loss (70 ± 74 and 26 ± 34 mL) during transection of the liver, as compared to saline-linked technology (2 ± 1 cm(2)/min with P = 0.002, and 527 ± 273 mL with P = 0.001). CONCLUSION: A new RF-assisted device for bloodless, rapid liver resection was designed, built and tested. The results demonstrate the potential advantages of this device over others currently employed.
format Text
id pubmed-2672929
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-26729292009-04-24 Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments Burdío, Fernando Berjano, Enrique J Navarro, Ana Burdío, José M Grande, Luis Gonzalez, Ana Cruz, Ignacio Güemes, Antonio Sousa, Ramón Subirá, Jorge Castiella, Tomás Poves, Ignasi Lequerica, Juan L Biomed Eng Online Research BACKGROUND: Efficient and safe transection of biological tissue in liver surgery is strongly dependent on the ability to address both parenchymal division and hemostasis simultaneously. In addition to the conventional clamp crushing or finger fracture methods other techniques based on radiofrequency (RF) currents have been extensively employed to reduce intraoperative blood loss. In this paper we present our broad research plan for a new RF-assisted device for bloodless, rapid resection of the liver. METHODS: Our research plan includes computer modeling and in vivo studies. Computer modeling was based on the Finite Element Method (FEM) and allowed us to estimate the distribution of electrical power deposited in the tissue, along with assessing the effect of the characteristics of the device on the temperature profiles. Studies based on in vivo pig liver models provided a comparison of the performance of the new device with other techniques (saline-linked technology) currently employed in clinical practice. Finally, the plan includes a pilot clinical trial, in which both the new device and the accessory equipment are seen to comply with all safety requirements. RESULTS: The FEM results showed a high electrical gradient around the tip of the blade, responsible for the maximal increase of temperature at that point, where temperature reached 100°C in only 3.85 s. Other hot points with lower temperatures were located at the proximal edge of the device. Additional simulations with an electrically insulated blade produced more uniform and larger lesions (assessed as the 55°C isotherm) than the electrically conducting blade. The in vivo study, in turn, showed greater transection speed (3 ± 0 and 3 ± 1 cm(2)/min for the new device in the open and laparoscopic approaches respectively) and also lower blood loss (70 ± 74 and 26 ± 34 mL) during transection of the liver, as compared to saline-linked technology (2 ± 1 cm(2)/min with P = 0.002, and 527 ± 273 mL with P = 0.001). CONCLUSION: A new RF-assisted device for bloodless, rapid liver resection was designed, built and tested. The results demonstrate the potential advantages of this device over others currently employed. BioMed Central 2009-03-18 /pmc/articles/PMC2672929/ /pubmed/19296852 http://dx.doi.org/10.1186/1475-925X-8-6 Text en Copyright © 2009 Burdío et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Burdío, Fernando
Berjano, Enrique J
Navarro, Ana
Burdío, José M
Grande, Luis
Gonzalez, Ana
Cruz, Ignacio
Güemes, Antonio
Sousa, Ramón
Subirá, Jorge
Castiella, Tomás
Poves, Ignasi
Lequerica, Juan L
Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments
title Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments
title_full Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments
title_fullStr Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments
title_full_unstemmed Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments
title_short Research and development of a new RF-assisted device for bloodless rapid transection of the liver: Computational modeling and in vivo experiments
title_sort research and development of a new rf-assisted device for bloodless rapid transection of the liver: computational modeling and in vivo experiments
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2672929/
https://www.ncbi.nlm.nih.gov/pubmed/19296852
http://dx.doi.org/10.1186/1475-925X-8-6
work_keys_str_mv AT burdiofernando researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT berjanoenriquej researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT navarroana researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT burdiojosem researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT grandeluis researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT gonzalezana researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT cruzignacio researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT guemesantonio researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT sousaramon researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT subirajorge researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT castiellatomas researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT povesignasi researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments
AT lequericajuanl researchanddevelopmentofanewrfassisteddeviceforbloodlessrapidtransectionofthelivercomputationalmodelingandinvivoexperiments