Cargando…

Collection of the BD SurePath Pap Test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination

OBJECTIVE: Here we examine the diagnostic utility of the US Food And Drug Administration (FDA) approved Spatula + endocervical brush combination for the BD SurePath Pap Test (SPPT) and compare it to SPPT collection with the broom alone or to an off-label combination of broom + EC brush. This questio...

Descripción completa

Detalles Bibliográficos
Autores principales: Davis-Devine, Sharon, Day, Sarah J., Anderson, Amy, French, Ashley, Madison-Henness, Darcy, Mohar, Naomi, Tansy, Danielle, Hiremath, Adarsh, Douglas, Jeffrey A., Freund, Gregory G.
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2678824/
https://www.ncbi.nlm.nih.gov/pubmed/19495403
http://dx.doi.org/10.4103/1742-6413.45495
_version_ 1782166851945496576
author Davis-Devine, Sharon
Day, Sarah J.
Anderson, Amy
French, Ashley
Madison-Henness, Darcy
Mohar, Naomi
Tansy, Danielle
Hiremath, Adarsh
Douglas, Jeffrey A.
Freund, Gregory G.
author_facet Davis-Devine, Sharon
Day, Sarah J.
Anderson, Amy
French, Ashley
Madison-Henness, Darcy
Mohar, Naomi
Tansy, Danielle
Hiremath, Adarsh
Douglas, Jeffrey A.
Freund, Gregory G.
author_sort Davis-Devine, Sharon
collection PubMed
description OBJECTIVE: Here we examine the diagnostic utility of the US Food And Drug Administration (FDA) approved Spatula + endocervical brush combination for the BD SurePath Pap Test (SPPT) and compare it to SPPT collection with the broom alone or to an off-label combination of broom + EC brush. This question is important due to lingering concerns over the value of EC detection to a satisfactory Pap test. METHODS: 20,125 SPPT vials were examined for the collection devices contained. The SPPT collection device combinations allowed were: Rovers Cervex-Brush (broom, FDA approved), Medscand Pap Perfect Spatula + Medscand CytoBrush Plus GT (spatula + GT brush, FDA approved) or Rovers Cervex-Brush + Surgipath C-E Brush (broom + CE brush, off label). RESULTS: Examination of SPPT vials revealed 11,130 collected with the broom, 4,687 collected with the spatula + GT brush and 2,921 collected with the broom + CE brush. Absence of an endocervical/transformation zone was seen in 22.86% of broom cases, 13.10% of spatula + GT brush cases (p= 0.00005 vs broom) and 10.17% of broom + CE brush cases (p= 0.00005 vs broom, p= 0.00005 vs spatula + GT brush). Importantly, LSIL detection was: broom 2.99%; spatula + GT brush 2.45% (p= 0.053 vs broom); broom + CE brush 4.18% (p= 0.034 vs broom, p= 0.0001 vs spatula + GT brush). CONCLUSION: When broom + brush combination is compared to broom alone or to spatula + GT brush, the broom + CE brush combination better sampled the endocervical/transformation zone and increased LSIL detection.
format Text
id pubmed-2678824
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-26788242009-05-11 Collection of the BD SurePath Pap Test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination Davis-Devine, Sharon Day, Sarah J. Anderson, Amy French, Ashley Madison-Henness, Darcy Mohar, Naomi Tansy, Danielle Hiremath, Adarsh Douglas, Jeffrey A. Freund, Gregory G. Cytojournal Original Article OBJECTIVE: Here we examine the diagnostic utility of the US Food And Drug Administration (FDA) approved Spatula + endocervical brush combination for the BD SurePath Pap Test (SPPT) and compare it to SPPT collection with the broom alone or to an off-label combination of broom + EC brush. This question is important due to lingering concerns over the value of EC detection to a satisfactory Pap test. METHODS: 20,125 SPPT vials were examined for the collection devices contained. The SPPT collection device combinations allowed were: Rovers Cervex-Brush (broom, FDA approved), Medscand Pap Perfect Spatula + Medscand CytoBrush Plus GT (spatula + GT brush, FDA approved) or Rovers Cervex-Brush + Surgipath C-E Brush (broom + CE brush, off label). RESULTS: Examination of SPPT vials revealed 11,130 collected with the broom, 4,687 collected with the spatula + GT brush and 2,921 collected with the broom + CE brush. Absence of an endocervical/transformation zone was seen in 22.86% of broom cases, 13.10% of spatula + GT brush cases (p= 0.00005 vs broom) and 10.17% of broom + CE brush cases (p= 0.00005 vs broom, p= 0.00005 vs spatula + GT brush). Importantly, LSIL detection was: broom 2.99%; spatula + GT brush 2.45% (p= 0.053 vs broom); broom + CE brush 4.18% (p= 0.034 vs broom, p= 0.0001 vs spatula + GT brush). CONCLUSION: When broom + brush combination is compared to broom alone or to spatula + GT brush, the broom + CE brush combination better sampled the endocervical/transformation zone and increased LSIL detection. Medknow Publications 2008-02-12 /pmc/articles/PMC2678824/ /pubmed/19495403 http://dx.doi.org/10.4103/1742-6413.45495 Text en © 2009 Davis-Devine et al; licensee Cytopathology Foundation Inc. http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Davis-Devine, Sharon
Day, Sarah J.
Anderson, Amy
French, Ashley
Madison-Henness, Darcy
Mohar, Naomi
Tansy, Danielle
Hiremath, Adarsh
Douglas, Jeffrey A.
Freund, Gregory G.
Collection of the BD SurePath Pap Test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination
title Collection of the BD SurePath Pap Test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination
title_full Collection of the BD SurePath Pap Test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination
title_fullStr Collection of the BD SurePath Pap Test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination
title_full_unstemmed Collection of the BD SurePath Pap Test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination
title_short Collection of the BD SurePath Pap Test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination
title_sort collection of the bd surepath pap test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2678824/
https://www.ncbi.nlm.nih.gov/pubmed/19495403
http://dx.doi.org/10.4103/1742-6413.45495
work_keys_str_mv AT davisdevinesharon collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination
AT daysarahj collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination
AT andersonamy collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination
AT frenchashley collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination
AT madisonhennessdarcy collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination
AT moharnaomi collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination
AT tansydanielle collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination
AT hiremathadarsh collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination
AT douglasjeffreya collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination
AT freundgregoryg collectionofthebdsurepathpaptestwithabroomdeviceplusendocervicalbrushimprovesdiseasedetectionwhencomparedtothebroomdevicealoneorthespatulaplusendocervicalbrushcombination