Cargando…

Comparison of the efficacy of the cervex brush and the extended-tip wooden spatula with conventional cytology: A longitudinal study

BACKGROUND: Within the United Kingdom, the change from conventional to liquid based cytology (LBC) has brought with it the universal introduction of broom style samplers, as represented by the Cervex sampler. The aim of this study was to assess whether or not there were benefits associated with a ch...

Descripción completa

Detalles Bibliográficos
Autores principales: Whitaker, Caroline J, Stamp, Elaine C, Young, William, Greenwood, Lesley A
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2678826/
https://www.ncbi.nlm.nih.gov/pubmed/19495406
http://dx.doi.org/10.4103/1742-6413.45192
_version_ 1782166852423647232
author Whitaker, Caroline J
Stamp, Elaine C
Young, William
Greenwood, Lesley A
author_facet Whitaker, Caroline J
Stamp, Elaine C
Young, William
Greenwood, Lesley A
author_sort Whitaker, Caroline J
collection PubMed
description BACKGROUND: Within the United Kingdom, the change from conventional to liquid based cytology (LBC) has brought with it the universal introduction of broom style samplers, as represented by the Cervex sampler. The aim of this study was to assess whether or not there were benefits associated with a change from wooden spatulae to broom style samplers for those countries where conversion to LBC might not be readily available or is not fully supported. METHODS: A longitudinal study was designed to compare the performance of Cervex brushes and extended-tip wooden spatulae as sampling devices for conventionally prepared cervical smears. General Practices serving the population of Hull and East Yorkshire (UK) were provided with Cervex brushes for a period of nine months to routinely collect cervical smears. The results of 66,931 cervical smear tests were compared between those practices that were using extended-tip wooden spatulae before the trial and then returned to their use afterwards, and those who were previously using Cervex samplers and continued to use them throughout. Analyses comparing both specimen inadequacy, as recorded on the standard cervical screening request form (HMR101), and also the presence of identified transformation zone (TZ) elements in smears, both indicated significant advantages associated with the Cervex brush. RESULTS: Inadequate smears decreased from 5.96% with extended-tip spatulae to 4.77% with Cervex brushes (p<0.001) and increased back to 7.34% when practices reverted to extended-tip spatulae after nine months. Under the same conditions, the proportion of smears containing identified TZ elements increased from 50.52% to 54.75% (p<0.001), before reverting to 45.47% (p<0.001). In contrast, for a control group of practices using the Cervex brush throughout, inadequate smears decreased in all phases of the study, with no significant variation in TZ sampling rates. CONCLUSIONS: Using the Cervex brush with conventional cytology significantly decreases inadequate smears and increases TZ sampling when compared to the extended-tip spatula and can offer improved cervical screening in countries unable or unwilling to convert to LBC.
format Text
id pubmed-2678826
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-26788262009-05-11 Comparison of the efficacy of the cervex brush and the extended-tip wooden spatula with conventional cytology: A longitudinal study Whitaker, Caroline J Stamp, Elaine C Young, William Greenwood, Lesley A Cytojournal Original Article BACKGROUND: Within the United Kingdom, the change from conventional to liquid based cytology (LBC) has brought with it the universal introduction of broom style samplers, as represented by the Cervex sampler. The aim of this study was to assess whether or not there were benefits associated with a change from wooden spatulae to broom style samplers for those countries where conversion to LBC might not be readily available or is not fully supported. METHODS: A longitudinal study was designed to compare the performance of Cervex brushes and extended-tip wooden spatulae as sampling devices for conventionally prepared cervical smears. General Practices serving the population of Hull and East Yorkshire (UK) were provided with Cervex brushes for a period of nine months to routinely collect cervical smears. The results of 66,931 cervical smear tests were compared between those practices that were using extended-tip wooden spatulae before the trial and then returned to their use afterwards, and those who were previously using Cervex samplers and continued to use them throughout. Analyses comparing both specimen inadequacy, as recorded on the standard cervical screening request form (HMR101), and also the presence of identified transformation zone (TZ) elements in smears, both indicated significant advantages associated with the Cervex brush. RESULTS: Inadequate smears decreased from 5.96% with extended-tip spatulae to 4.77% with Cervex brushes (p<0.001) and increased back to 7.34% when practices reverted to extended-tip spatulae after nine months. Under the same conditions, the proportion of smears containing identified TZ elements increased from 50.52% to 54.75% (p<0.001), before reverting to 45.47% (p<0.001). In contrast, for a control group of practices using the Cervex brush throughout, inadequate smears decreased in all phases of the study, with no significant variation in TZ sampling rates. CONCLUSIONS: Using the Cervex brush with conventional cytology significantly decreases inadequate smears and increases TZ sampling when compared to the extended-tip spatula and can offer improved cervical screening in countries unable or unwilling to convert to LBC. Medknow Publications 2009-01-19 /pmc/articles/PMC2678826/ /pubmed/19495406 http://dx.doi.org/10.4103/1742-6413.45192 Text en © 2009 Whitaker et al; licensee Cytopathology Foundation Inc. http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Whitaker, Caroline J
Stamp, Elaine C
Young, William
Greenwood, Lesley A
Comparison of the efficacy of the cervex brush and the extended-tip wooden spatula with conventional cytology: A longitudinal study
title Comparison of the efficacy of the cervex brush and the extended-tip wooden spatula with conventional cytology: A longitudinal study
title_full Comparison of the efficacy of the cervex brush and the extended-tip wooden spatula with conventional cytology: A longitudinal study
title_fullStr Comparison of the efficacy of the cervex brush and the extended-tip wooden spatula with conventional cytology: A longitudinal study
title_full_unstemmed Comparison of the efficacy of the cervex brush and the extended-tip wooden spatula with conventional cytology: A longitudinal study
title_short Comparison of the efficacy of the cervex brush and the extended-tip wooden spatula with conventional cytology: A longitudinal study
title_sort comparison of the efficacy of the cervex brush and the extended-tip wooden spatula with conventional cytology: a longitudinal study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2678826/
https://www.ncbi.nlm.nih.gov/pubmed/19495406
http://dx.doi.org/10.4103/1742-6413.45192
work_keys_str_mv AT whitakercarolinej comparisonoftheefficacyofthecervexbrushandtheextendedtipwoodenspatulawithconventionalcytologyalongitudinalstudy
AT stampelainec comparisonoftheefficacyofthecervexbrushandtheextendedtipwoodenspatulawithconventionalcytologyalongitudinalstudy
AT youngwilliam comparisonoftheefficacyofthecervexbrushandtheextendedtipwoodenspatulawithconventionalcytologyalongitudinalstudy
AT greenwoodlesleya comparisonoftheefficacyofthecervexbrushandtheextendedtipwoodenspatulawithconventionalcytologyalongitudinalstudy