Cargando…
Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean
PURPOSE: Kidney volume is regarded as the most precise indicator of kidney size. However, it is not widely used clinically, because its measurement is difficult due to the complex kidney shape. We attempted to evaluate the normal kidney volume in young Korean men by using multi-detector computed tom...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2679189/ https://www.ncbi.nlm.nih.gov/pubmed/19430561 http://dx.doi.org/10.3349/ymj.2009.50.2.262 |
_version_ | 1782166883155312640 |
---|---|
author | Shin, Ho Sik Chung, Byung Ha Lee, Sang Eun Kim, Woo Jin Ha, Hong Il Yang, Chul Woo |
author_facet | Shin, Ho Sik Chung, Byung Ha Lee, Sang Eun Kim, Woo Jin Ha, Hong Il Yang, Chul Woo |
author_sort | Shin, Ho Sik |
collection | PubMed |
description | PURPOSE: Kidney volume is regarded as the most precise indicator of kidney size. However, it is not widely used clinically, because its measurement is difficult due to the complex kidney shape. We attempted to evaluate the normal kidney volume in young Korean men by using multi-detector computed tomography (MDCT). MATERIALS AND METHODS: We retrospectively reviewed MDCT data of young Korean men (113 patients). After data processing, we measured the volume and length of the kidneys. Body parameters (height, body weight, body-surface area, and total body water) and laboratory data were collected. Glomerular filtration rate (GFR) was calculated using Cockcroft-Gault (CG) equation. RESULTS: The mean kidney volume was 205.29 ± 36.81 cm(3); and mean kidney length was 10.80 ± 0.69 cm. The former correlated significantly with height, body weight, body-surface area, and total body water (p < 0.05, correlation coefficient : γ = 0.328, 0.649, 0.640, and 0.638, respectively). The latter also correlated significantly with all body indexes, however the correlation was weaker, except with height (p < 0.05, correlation coefficient : γ = 0.457, 0.473, 0.505, and 0.503, respectively). Only kidney volume significantly predicted estimated GFR (adjusted R(2) = 0.431, F = 85.90 and p < 0.05). CONCLUSION: The kidney volume measured with MDCT is correlated well with body parameters, and is useful to predict renal function. |
format | Text |
id | pubmed-2679189 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-26791892009-05-08 Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean Shin, Ho Sik Chung, Byung Ha Lee, Sang Eun Kim, Woo Jin Ha, Hong Il Yang, Chul Woo Yonsei Med J Original Article PURPOSE: Kidney volume is regarded as the most precise indicator of kidney size. However, it is not widely used clinically, because its measurement is difficult due to the complex kidney shape. We attempted to evaluate the normal kidney volume in young Korean men by using multi-detector computed tomography (MDCT). MATERIALS AND METHODS: We retrospectively reviewed MDCT data of young Korean men (113 patients). After data processing, we measured the volume and length of the kidneys. Body parameters (height, body weight, body-surface area, and total body water) and laboratory data were collected. Glomerular filtration rate (GFR) was calculated using Cockcroft-Gault (CG) equation. RESULTS: The mean kidney volume was 205.29 ± 36.81 cm(3); and mean kidney length was 10.80 ± 0.69 cm. The former correlated significantly with height, body weight, body-surface area, and total body water (p < 0.05, correlation coefficient : γ = 0.328, 0.649, 0.640, and 0.638, respectively). The latter also correlated significantly with all body indexes, however the correlation was weaker, except with height (p < 0.05, correlation coefficient : γ = 0.457, 0.473, 0.505, and 0.503, respectively). Only kidney volume significantly predicted estimated GFR (adjusted R(2) = 0.431, F = 85.90 and p < 0.05). CONCLUSION: The kidney volume measured with MDCT is correlated well with body parameters, and is useful to predict renal function. Yonsei University College of Medicine 2009-04-30 2009-04-30 /pmc/articles/PMC2679189/ /pubmed/19430561 http://dx.doi.org/10.3349/ymj.2009.50.2.262 Text en © Copyright: Yonsei University College of Medicine 2009 http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Shin, Ho Sik Chung, Byung Ha Lee, Sang Eun Kim, Woo Jin Ha, Hong Il Yang, Chul Woo Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean |
title | Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean |
title_full | Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean |
title_fullStr | Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean |
title_full_unstemmed | Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean |
title_short | Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean |
title_sort | measurement of kidney volume with multi-detector computed tomography scanning in young korean |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2679189/ https://www.ncbi.nlm.nih.gov/pubmed/19430561 http://dx.doi.org/10.3349/ymj.2009.50.2.262 |
work_keys_str_mv | AT shinhosik measurementofkidneyvolumewithmultidetectorcomputedtomographyscanninginyoungkorean AT chungbyungha measurementofkidneyvolumewithmultidetectorcomputedtomographyscanninginyoungkorean AT leesangeun measurementofkidneyvolumewithmultidetectorcomputedtomographyscanninginyoungkorean AT kimwoojin measurementofkidneyvolumewithmultidetectorcomputedtomographyscanninginyoungkorean AT hahongil measurementofkidneyvolumewithmultidetectorcomputedtomographyscanninginyoungkorean AT yangchulwoo measurementofkidneyvolumewithmultidetectorcomputedtomographyscanninginyoungkorean |