Cargando…

Effect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth

The purpose of this study was to verify the influence of flask closure methods and post-pressing times on tooth displacement in maxillary dentures. Twenty similar maxillary dentures were made using a heat-polymerized acrylic resin, and randomly assigned to 4 experimental groups (n=5) according to th...

Descripción completa

Detalles Bibliográficos
Autores principales: Negreiros, Wagner A, Consani, Rafael L.X, Mesquita, Marcelo F, Sinhoreti, Mario A.C, Faria, Ivan R
Formato: Texto
Lenguaje:English
Publicado: Bentham Open 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2681168/
https://www.ncbi.nlm.nih.gov/pubmed/19444339
http://dx.doi.org/10.2174/1874210600903010021
_version_ 1782167020322684928
author Negreiros, Wagner A
Consani, Rafael L.X
Mesquita, Marcelo F
Sinhoreti, Mario A.C
Faria, Ivan R
author_facet Negreiros, Wagner A
Consani, Rafael L.X
Mesquita, Marcelo F
Sinhoreti, Mario A.C
Faria, Ivan R
author_sort Negreiros, Wagner A
collection PubMed
description The purpose of this study was to verify the influence of flask closure methods and post-pressing times on tooth displacement in maxillary dentures. Twenty similar maxillary dentures were made using a heat-polymerized acrylic resin, and randomly assigned to 4 experimental groups (n=5) according to the protocol: 1-conventional flask closure and immediate polymerization; 2- conventional flask closure and polymerization after 6-hour post-pressing time; 3- RS flask closure system and immediate polymerization; and 4- RS flask closure system and polymerization after 6-hour post-pressing time. Three transverse and 2 anteroposterior linear distances between teeth were measured before and after the denture processing with an optical microscope with accuracy of 0.0005mm. Analysis of variance (ANOVA) and Tukey’s test were performed to compare the results. The 6-hour post-pressing time (conventional = 0.44mm and RS = 0.33mm) showed no statistically significant difference in tooth movement, in relation to the flask closure methods, when compared to the immediate time (conventional = 0.40mm and RS = 0.28mm). The RS system standardized the tooth displacement, independently of the post-pressing times. Dimensional changes were more uniform when the dentures were submitted to the 6-hour post-pressing time and RS flask closure method, suggesting that these factors may reduce the magnitude of tooth movement.
format Text
id pubmed-2681168
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-26811682009-05-14 Effect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth Negreiros, Wagner A Consani, Rafael L.X Mesquita, Marcelo F Sinhoreti, Mario A.C Faria, Ivan R Open Dent J Article The purpose of this study was to verify the influence of flask closure methods and post-pressing times on tooth displacement in maxillary dentures. Twenty similar maxillary dentures were made using a heat-polymerized acrylic resin, and randomly assigned to 4 experimental groups (n=5) according to the protocol: 1-conventional flask closure and immediate polymerization; 2- conventional flask closure and polymerization after 6-hour post-pressing time; 3- RS flask closure system and immediate polymerization; and 4- RS flask closure system and polymerization after 6-hour post-pressing time. Three transverse and 2 anteroposterior linear distances between teeth were measured before and after the denture processing with an optical microscope with accuracy of 0.0005mm. Analysis of variance (ANOVA) and Tukey’s test were performed to compare the results. The 6-hour post-pressing time (conventional = 0.44mm and RS = 0.33mm) showed no statistically significant difference in tooth movement, in relation to the flask closure methods, when compared to the immediate time (conventional = 0.40mm and RS = 0.28mm). The RS system standardized the tooth displacement, independently of the post-pressing times. Dimensional changes were more uniform when the dentures were submitted to the 6-hour post-pressing time and RS flask closure method, suggesting that these factors may reduce the magnitude of tooth movement. Bentham Open 2009-03-06 /pmc/articles/PMC2681168/ /pubmed/19444339 http://dx.doi.org/10.2174/1874210600903010021 Text en © Negreiros et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Negreiros, Wagner A
Consani, Rafael L.X
Mesquita, Marcelo F
Sinhoreti, Mario A.C
Faria, Ivan R
Effect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth
title Effect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth
title_full Effect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth
title_fullStr Effect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth
title_full_unstemmed Effect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth
title_short Effect of Flask Closure Method and Post-Pressing Time on the Displacement of Maxillary Denture Teeth
title_sort effect of flask closure method and post-pressing time on the displacement of maxillary denture teeth
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2681168/
https://www.ncbi.nlm.nih.gov/pubmed/19444339
http://dx.doi.org/10.2174/1874210600903010021
work_keys_str_mv AT negreiroswagnera effectofflaskclosuremethodandpostpressingtimeonthedisplacementofmaxillarydentureteeth
AT consanirafaellx effectofflaskclosuremethodandpostpressingtimeonthedisplacementofmaxillarydentureteeth
AT mesquitamarcelof effectofflaskclosuremethodandpostpressingtimeonthedisplacementofmaxillarydentureteeth
AT sinhoretimarioac effectofflaskclosuremethodandpostpressingtimeonthedisplacementofmaxillarydentureteeth
AT fariaivanr effectofflaskclosuremethodandpostpressingtimeonthedisplacementofmaxillarydentureteeth