Effect of multiple impacts on protective properties of external hip protectors

A variety of external hip protectors are available on the market but no standards for their performance exist and it is unknown if their properties change after repeated fall impacts. The purpose of this study was to determine if protective properties change in different types of new (unused) hip pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Bulat, Tatjana, Applegarth, Shawn, Wilkinson, Stuart, Fitzgerald, Shirley G, Ahmed, Shahbaz, Quigley, Patricia
Formato: Texto
Lenguaje:English
Publicado: Dove Medical Press 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2682389/
https://www.ncbi.nlm.nih.gov/pubmed/18982927
_version_ 1782167048185446400
author Bulat, Tatjana
Applegarth, Shawn
Wilkinson, Stuart
Fitzgerald, Shirley G
Ahmed, Shahbaz
Quigley, Patricia
author_facet Bulat, Tatjana
Applegarth, Shawn
Wilkinson, Stuart
Fitzgerald, Shirley G
Ahmed, Shahbaz
Quigley, Patricia
author_sort Bulat, Tatjana
collection PubMed
description A variety of external hip protectors are available on the market but no standards for their performance exist and it is unknown if their properties change after repeated fall impacts. The purpose of this study was to determine if protective properties change in different types of new (unused) hip protectors after repeated, simulated falls. Five hip protector brands were chosen to represent different products available on the market and the two mechanisms employed in reducing the force of an impact (shunting or absorbing). Ten pairs of each type (20 pads for each brand) were tested using a 1.8-m Instron Dynatup 9250 HV vertical impact testing tower. The impact testing system was specifically designed for this study by creating a simulated trochanter to provide more accurately a impact area similar to that of a real hip bone. The hip protectors were impacted once a day for 3 consecutive days. Repeated impacts demonstrated the pads’ decreased ability to either absorb or shunt force in all types of hip protectors. However, the mean forces were still in the protective range (force below fracture threshold of 3100 N) for 3 of the 5 brands tested after 3 impacts. The protective properties of external hip protectors do degrade after repeated impacts. The degree of degradation differs from brand to brand. Regardless of type, most pads were still able to bring the force of impact below the fracture threshold of 3100 N. Future studies need to address the issue of durability of different types/brands of hip protectors after repeated laundering and fall impacts to determine when should they be replaced. Additionally, a national or international standard needs to be developed against which the performance of different brands of hip protectors can be compared.
format Text
id pubmed-2682389
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-26823892009-05-20 Effect of multiple impacts on protective properties of external hip protectors Bulat, Tatjana Applegarth, Shawn Wilkinson, Stuart Fitzgerald, Shirley G Ahmed, Shahbaz Quigley, Patricia Clin Interv Aging Original Research A variety of external hip protectors are available on the market but no standards for their performance exist and it is unknown if their properties change after repeated fall impacts. The purpose of this study was to determine if protective properties change in different types of new (unused) hip protectors after repeated, simulated falls. Five hip protector brands were chosen to represent different products available on the market and the two mechanisms employed in reducing the force of an impact (shunting or absorbing). Ten pairs of each type (20 pads for each brand) were tested using a 1.8-m Instron Dynatup 9250 HV vertical impact testing tower. The impact testing system was specifically designed for this study by creating a simulated trochanter to provide more accurately a impact area similar to that of a real hip bone. The hip protectors were impacted once a day for 3 consecutive days. Repeated impacts demonstrated the pads’ decreased ability to either absorb or shunt force in all types of hip protectors. However, the mean forces were still in the protective range (force below fracture threshold of 3100 N) for 3 of the 5 brands tested after 3 impacts. The protective properties of external hip protectors do degrade after repeated impacts. The degree of degradation differs from brand to brand. Regardless of type, most pads were still able to bring the force of impact below the fracture threshold of 3100 N. Future studies need to address the issue of durability of different types/brands of hip protectors after repeated laundering and fall impacts to determine when should they be replaced. Additionally, a national or international standard needs to be developed against which the performance of different brands of hip protectors can be compared. Dove Medical Press 2008-09 2008-09 /pmc/articles/PMC2682389/ /pubmed/18982927 Text en © 2008 Dove Medical Press Limited. All rights reserved
spellingShingle Original Research
Bulat, Tatjana
Applegarth, Shawn
Wilkinson, Stuart
Fitzgerald, Shirley G
Ahmed, Shahbaz
Quigley, Patricia
Effect of multiple impacts on protective properties of external hip protectors
title Effect of multiple impacts on protective properties of external hip protectors
title_full Effect of multiple impacts on protective properties of external hip protectors
title_fullStr Effect of multiple impacts on protective properties of external hip protectors
title_full_unstemmed Effect of multiple impacts on protective properties of external hip protectors
title_short Effect of multiple impacts on protective properties of external hip protectors
title_sort effect of multiple impacts on protective properties of external hip protectors
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2682389/
https://www.ncbi.nlm.nih.gov/pubmed/18982927
work_keys_str_mv AT bulattatjana effectofmultipleimpactsonprotectivepropertiesofexternalhipprotectors
AT applegarthshawn effectofmultipleimpactsonprotectivepropertiesofexternalhipprotectors
AT wilkinsonstuart effectofmultipleimpactsonprotectivepropertiesofexternalhipprotectors
AT fitzgeraldshirleyg effectofmultipleimpactsonprotectivepropertiesofexternalhipprotectors
AT ahmedshahbaz effectofmultipleimpactsonprotectivepropertiesofexternalhipprotectors
AT quigleypatricia effectofmultipleimpactsonprotectivepropertiesofexternalhipprotectors