Cargando…

Error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra

BACKGROUND: The transmission electron microscope is used to acquire structural information of macromolecular complexes. However, as any other imaging device, it introduces optical aberrations that must be corrected if high-resolution structural information is to be obtained. The set of all aberratio...

Descripción completa

Detalles Bibliográficos
Autores principales: Sorzano, Carlos Oscar S, Otero, Abraham, Olmos, Estefanía M, Carazo, José María
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2683171/
https://www.ncbi.nlm.nih.gov/pubmed/19321015
http://dx.doi.org/10.1186/1472-6807-9-18
_version_ 1782167111190183936
author Sorzano, Carlos Oscar S
Otero, Abraham
Olmos, Estefanía M
Carazo, José María
author_facet Sorzano, Carlos Oscar S
Otero, Abraham
Olmos, Estefanía M
Carazo, José María
author_sort Sorzano, Carlos Oscar S
collection PubMed
description BACKGROUND: The transmission electron microscope is used to acquire structural information of macromolecular complexes. However, as any other imaging device, it introduces optical aberrations that must be corrected if high-resolution structural information is to be obtained. The set of all aberrations are usually modeled in Fourier space by the so-called Contrast Transfer Function (CTF). Before correcting for the CTF, we must first estimate it from the electron micrographs. This is usually done by estimating a number of parameters specifying a theoretical model of the CTF. This estimation is performed by minimizing some error measure between the theoretical Power Spectrum Density (PSD) and the experimentally observed PSD. The high noise present in the micrographs, the possible local minima of the error function for estimating the CTF parameters, and the cross-talking between CTF parameters may cause errors in the estimated CTF parameters. RESULTS: In this paper, we explore the effect of these estimation errors on the theoretical CTF. For the CTF model proposed in [1] we show which are the most sensitive CTF parameters as well as the most sensitive background parameters. Moreover, we provide a methodology to reveal the internal structure of the CTF model (which parameters influence in which parameters) and to estimate the accuracy of each model parameter. Finally, we explore the effect of the variability in the detection of the CTF for CTF phase and amplitude correction. CONCLUSION: We show that the estimation errors for the CTF detection methodology proposed in [1] does not show a significant deterioration of the CTF correction capabilities of subsequent algorithms. All together, the methodology described in this paper constitutes a powerful tool for the quantitative analysis of CTF models that can be applied to other models different from the one analyzed here.
format Text
id pubmed-2683171
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-26831712009-05-18 Error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra Sorzano, Carlos Oscar S Otero, Abraham Olmos, Estefanía M Carazo, José María BMC Struct Biol Methodology Article BACKGROUND: The transmission electron microscope is used to acquire structural information of macromolecular complexes. However, as any other imaging device, it introduces optical aberrations that must be corrected if high-resolution structural information is to be obtained. The set of all aberrations are usually modeled in Fourier space by the so-called Contrast Transfer Function (CTF). Before correcting for the CTF, we must first estimate it from the electron micrographs. This is usually done by estimating a number of parameters specifying a theoretical model of the CTF. This estimation is performed by minimizing some error measure between the theoretical Power Spectrum Density (PSD) and the experimentally observed PSD. The high noise present in the micrographs, the possible local minima of the error function for estimating the CTF parameters, and the cross-talking between CTF parameters may cause errors in the estimated CTF parameters. RESULTS: In this paper, we explore the effect of these estimation errors on the theoretical CTF. For the CTF model proposed in [1] we show which are the most sensitive CTF parameters as well as the most sensitive background parameters. Moreover, we provide a methodology to reveal the internal structure of the CTF model (which parameters influence in which parameters) and to estimate the accuracy of each model parameter. Finally, we explore the effect of the variability in the detection of the CTF for CTF phase and amplitude correction. CONCLUSION: We show that the estimation errors for the CTF detection methodology proposed in [1] does not show a significant deterioration of the CTF correction capabilities of subsequent algorithms. All together, the methodology described in this paper constitutes a powerful tool for the quantitative analysis of CTF models that can be applied to other models different from the one analyzed here. BioMed Central 2009-03-26 /pmc/articles/PMC2683171/ /pubmed/19321015 http://dx.doi.org/10.1186/1472-6807-9-18 Text en Copyright © 2009 Sorzano et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology Article
Sorzano, Carlos Oscar S
Otero, Abraham
Olmos, Estefanía M
Carazo, José María
Error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra
title Error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra
title_full Error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra
title_fullStr Error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra
title_full_unstemmed Error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra
title_short Error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power Spectra
title_sort error analysis in the determination of the electron microscopical contrast transfer function parameters from experimental power spectra
topic Methodology Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2683171/
https://www.ncbi.nlm.nih.gov/pubmed/19321015
http://dx.doi.org/10.1186/1472-6807-9-18
work_keys_str_mv AT sorzanocarlososcars erroranalysisinthedeterminationoftheelectronmicroscopicalcontrasttransferfunctionparametersfromexperimentalpowerspectra
AT oteroabraham erroranalysisinthedeterminationoftheelectronmicroscopicalcontrasttransferfunctionparametersfromexperimentalpowerspectra
AT olmosestefaniam erroranalysisinthedeterminationoftheelectronmicroscopicalcontrasttransferfunctionparametersfromexperimentalpowerspectra
AT carazojosemaria erroranalysisinthedeterminationoftheelectronmicroscopicalcontrasttransferfunctionparametersfromexperimentalpowerspectra