Cargando…

Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)

Background. Microbial infections are the most serious complications associated with indwelling central venous catheters. A catheter lock solution that is both antibacterial and antithrombotic is needed. The goal of this study was to determine whether a new catheter lock solution containing citrate,...

Descripción completa

Detalles Bibliográficos
Autores principales: Steczko, Janusz, Ash, Stephen R., Nivens, David E., Brewer, Lloyd, Winger, Roland K.
Formato: Texto
Lenguaje:English
Publicado: Oxford University Press 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2684753/
https://www.ncbi.nlm.nih.gov/pubmed/19181762
http://dx.doi.org/10.1093/ndt/gfn776
_version_ 1782167264032718848
author Steczko, Janusz
Ash, Stephen R.
Nivens, David E.
Brewer, Lloyd
Winger, Roland K.
author_facet Steczko, Janusz
Ash, Stephen R.
Nivens, David E.
Brewer, Lloyd
Winger, Roland K.
author_sort Steczko, Janusz
collection PubMed
description Background. Microbial infections are the most serious complications associated with indwelling central venous catheters. A catheter lock solution that is both antibacterial and antithrombotic is needed. The goal of this study was to determine whether a new catheter lock solution containing citrate, methylene blue and parabens has antimicrobial properties against planktonic bacteria and against sessile bacteria within a biofilm. These effects were compared to the antimicrobial properties of heparin at 2500 units/ml. Methods. The tested solution (C/MB/P comprising 7% sodium citrate, 0.05% methylene blue and 0.165% parabens) and individual components were challenged against gram-positive and gram-negative organisms and fungi. Control solutions were heparin with preservatives. Studies included evaluation of eradication of planktonic bacteria and sessile organisms in a biofilm grown on polymeric and glass coupons. Biofilm samples were inspected by scanning electron microscopy, atomic force microscopy and vital stains. Results. The C/MB/P solution, contrary to heparin, kills most tested planktonic microorganisms within 1 h of incubation. All tested organisms have an MIC of 25% or less of the original concentration of a new catheter lock. Bacteria strains did not develop resistance over more than 40 passages of culture suspensions. The C/MB/P solution is able to kill nearly all sessile bacteria in biofilm growth on plastic or glass discs in 1 h. Microscopic methods demonstrated extensive physical elimination of biofilm deposits from treated coupons. In contrast, heparin had a minimal effect on planktonic or biofilm organisms. Conclusions. The new multicomponent lock solution has strong antimicrobial properties against both planktonic and sessile microorganisms. By comparison, heparin with preservative has weak antibacterial properties against planktonic and biofilm bacteria. The tested catheter lock may have usefulness in preventing bacterial colonization of haemodialysis catheters and diminishing the incidence of catheter-related bacteraemia.
format Text
id pubmed-2684753
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-26847532009-05-21 Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens) Steczko, Janusz Ash, Stephen R. Nivens, David E. Brewer, Lloyd Winger, Roland K. Nephrol Dial Transplant Dialysis Background. Microbial infections are the most serious complications associated with indwelling central venous catheters. A catheter lock solution that is both antibacterial and antithrombotic is needed. The goal of this study was to determine whether a new catheter lock solution containing citrate, methylene blue and parabens has antimicrobial properties against planktonic bacteria and against sessile bacteria within a biofilm. These effects were compared to the antimicrobial properties of heparin at 2500 units/ml. Methods. The tested solution (C/MB/P comprising 7% sodium citrate, 0.05% methylene blue and 0.165% parabens) and individual components were challenged against gram-positive and gram-negative organisms and fungi. Control solutions were heparin with preservatives. Studies included evaluation of eradication of planktonic bacteria and sessile organisms in a biofilm grown on polymeric and glass coupons. Biofilm samples were inspected by scanning electron microscopy, atomic force microscopy and vital stains. Results. The C/MB/P solution, contrary to heparin, kills most tested planktonic microorganisms within 1 h of incubation. All tested organisms have an MIC of 25% or less of the original concentration of a new catheter lock. Bacteria strains did not develop resistance over more than 40 passages of culture suspensions. The C/MB/P solution is able to kill nearly all sessile bacteria in biofilm growth on plastic or glass discs in 1 h. Microscopic methods demonstrated extensive physical elimination of biofilm deposits from treated coupons. In contrast, heparin had a minimal effect on planktonic or biofilm organisms. Conclusions. The new multicomponent lock solution has strong antimicrobial properties against both planktonic and sessile microorganisms. By comparison, heparin with preservative has weak antibacterial properties against planktonic and biofilm bacteria. The tested catheter lock may have usefulness in preventing bacterial colonization of haemodialysis catheters and diminishing the incidence of catheter-related bacteraemia. Oxford University Press 2009-06 2009-01-30 /pmc/articles/PMC2684753/ /pubmed/19181762 http://dx.doi.org/10.1093/ndt/gfn776 Text en © The Author [2009]. http://creativecommons.org/licenses/by-nc/2.0/uk/ The online version of this article has been published under an open access model. Users are entitled to use, reproduce, disseminate, or display the open access version of this article for non-commercial purposes provided that: the original authorship is properly and fully attributed; the Journal and Oxford University Press are attributed as the original place of publication with the correct citation details given; if an article is subsequently reproduced or disseminated not in its entirety but only in part or as a derivative work this must be clearly indicated. For commercial re-use, please contact journals.permissions@oxfordjournals.org
spellingShingle Dialysis
Steczko, Janusz
Ash, Stephen R.
Nivens, David E.
Brewer, Lloyd
Winger, Roland K.
Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)
title Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)
title_full Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)
title_fullStr Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)
title_full_unstemmed Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)
title_short Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)
title_sort microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens)
topic Dialysis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2684753/
https://www.ncbi.nlm.nih.gov/pubmed/19181762
http://dx.doi.org/10.1093/ndt/gfn776
work_keys_str_mv AT steczkojanusz microbialinactivationpropertiesofanewantimicrobialantithromboticcatheterlocksolutioncitratemethyleneblueparabens
AT ashstephenr microbialinactivationpropertiesofanewantimicrobialantithromboticcatheterlocksolutioncitratemethyleneblueparabens
AT nivensdavide microbialinactivationpropertiesofanewantimicrobialantithromboticcatheterlocksolutioncitratemethyleneblueparabens
AT brewerlloyd microbialinactivationpropertiesofanewantimicrobialantithromboticcatheterlocksolutioncitratemethyleneblueparabens
AT wingerrolandk microbialinactivationpropertiesofanewantimicrobialantithromboticcatheterlocksolutioncitratemethyleneblueparabens