Cargando…

A complementary method for detecting qi vacuity

BACKGROUND: Qi vacuity (QV) is defined by traditional Chinese medicine as a loss of energy in the human body. An objective method for detecting QV was not available until recently, however. The automatic reflective diagnosis system (ARDK) is a device that detects human bioenergy through measuring sk...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Ming-Feng, Yu, Hsi-Ming, Li, Shu-Fang, You, Ta-Jung
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2687414/
https://www.ncbi.nlm.nih.gov/pubmed/19422719
http://dx.doi.org/10.1186/1472-6882-9-12
_version_ 1782167525969100800
author Chen, Ming-Feng
Yu, Hsi-Ming
Li, Shu-Fang
You, Ta-Jung
author_facet Chen, Ming-Feng
Yu, Hsi-Ming
Li, Shu-Fang
You, Ta-Jung
author_sort Chen, Ming-Feng
collection PubMed
description BACKGROUND: Qi vacuity (QV) is defined by traditional Chinese medicine as a loss of energy in the human body. An objective method for detecting QV was not available until recently, however. The automatic reflective diagnosis system (ARDK) is a device that detects human bioenergy through measuring skin conductance at 24 special acupoints on the wrists and ankles. METHODS: This study used the ARDK to measure skin conductance on 193 patients with QV and 89 sex- and age-matched healthy controls to investigate whether the device is useful in detecting QV. Patients diagnosed with QV have three or more of five symptoms or signs; symptom severity is measured on 5 levels and scored from 0 to 4 points. We compared the difference in the mean ARDK values between patients with QV and healthy controls, and further used linear regression analysis to investigate the correlation between the mean ARDK values and QV scores in patients diagnosed with QV. RESULTS: The mean ARDK values in patients with QV (30.2 ± 16.8 μA) are significantly lower than those of healthy controls (37.7 ± 10.8 μA; P < 0.001). A negative correlation was found between the mean ARDK values and QV scores (r coefficient = -0.61; P < 0.001). After adjusting for age, the decreased mean ARDK values in patients with QV showed a significant correlation with the QV scores. CONCLUSION: These results suggest that the mean ARDK values reflect the severity of QV in patients diagnosed with the disorder. They also suggest that the bioenergy level of the human body can be measured by skin conductance. ARDK is a safe and effective complementary method for detecting and diagnosing QV.
format Text
id pubmed-2687414
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-26874142009-05-28 A complementary method for detecting qi vacuity Chen, Ming-Feng Yu, Hsi-Ming Li, Shu-Fang You, Ta-Jung BMC Complement Altern Med Research Article BACKGROUND: Qi vacuity (QV) is defined by traditional Chinese medicine as a loss of energy in the human body. An objective method for detecting QV was not available until recently, however. The automatic reflective diagnosis system (ARDK) is a device that detects human bioenergy through measuring skin conductance at 24 special acupoints on the wrists and ankles. METHODS: This study used the ARDK to measure skin conductance on 193 patients with QV and 89 sex- and age-matched healthy controls to investigate whether the device is useful in detecting QV. Patients diagnosed with QV have three or more of five symptoms or signs; symptom severity is measured on 5 levels and scored from 0 to 4 points. We compared the difference in the mean ARDK values between patients with QV and healthy controls, and further used linear regression analysis to investigate the correlation between the mean ARDK values and QV scores in patients diagnosed with QV. RESULTS: The mean ARDK values in patients with QV (30.2 ± 16.8 μA) are significantly lower than those of healthy controls (37.7 ± 10.8 μA; P < 0.001). A negative correlation was found between the mean ARDK values and QV scores (r coefficient = -0.61; P < 0.001). After adjusting for age, the decreased mean ARDK values in patients with QV showed a significant correlation with the QV scores. CONCLUSION: These results suggest that the mean ARDK values reflect the severity of QV in patients diagnosed with the disorder. They also suggest that the bioenergy level of the human body can be measured by skin conductance. ARDK is a safe and effective complementary method for detecting and diagnosing QV. BioMed Central 2009-05-08 /pmc/articles/PMC2687414/ /pubmed/19422719 http://dx.doi.org/10.1186/1472-6882-9-12 Text en Copyright © 2009 Chen et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chen, Ming-Feng
Yu, Hsi-Ming
Li, Shu-Fang
You, Ta-Jung
A complementary method for detecting qi vacuity
title A complementary method for detecting qi vacuity
title_full A complementary method for detecting qi vacuity
title_fullStr A complementary method for detecting qi vacuity
title_full_unstemmed A complementary method for detecting qi vacuity
title_short A complementary method for detecting qi vacuity
title_sort complementary method for detecting qi vacuity
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2687414/
https://www.ncbi.nlm.nih.gov/pubmed/19422719
http://dx.doi.org/10.1186/1472-6882-9-12
work_keys_str_mv AT chenmingfeng acomplementarymethodfordetectingqivacuity
AT yuhsiming acomplementarymethodfordetectingqivacuity
AT lishufang acomplementarymethodfordetectingqivacuity
AT youtajung acomplementarymethodfordetectingqivacuity
AT chenmingfeng complementarymethodfordetectingqivacuity
AT yuhsiming complementarymethodfordetectingqivacuity
AT lishufang complementarymethodfordetectingqivacuity
AT youtajung complementarymethodfordetectingqivacuity