Cargando…

Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study

INTRODUCTION: Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypo...

Descripción completa

Detalles Bibliográficos
Autores principales: Dahl, Michael K, Vistisen, Simon T, Koefoed-Nielsen, Jacob, Larsson, Anders
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2689483/
https://www.ncbi.nlm.nih.gov/pubmed/19302700
http://dx.doi.org/10.1186/cc7760
_version_ 1782167801583108096
author Dahl, Michael K
Vistisen, Simon T
Koefoed-Nielsen, Jacob
Larsson, Anders
author_facet Dahl, Michael K
Vistisen, Simon T
Koefoed-Nielsen, Jacob
Larsson, Anders
author_sort Dahl, Michael K
collection PubMed
description INTRODUCTION: Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypothesized that during spontaneous breathing, inspiratory and/or expiratory resistors could induce high arterial pressure variations at hypovolemia and low variations at normovolemia and hypervolemia. Furthermore, we hypothesized that SPV and PPV could predict fluid responsiveness under these conditions. METHODS: Eight prone, anesthetized and spontaneously breathing pigs (20 to 25 kg) were subjected to a sequence of 30% hypovolemia, normovolemia, and 20% and 40% hypervolemia. At each volemic level, the pigs breathed in a randomized order either through an inspiratory and/or an expiratory threshold resistor (7.5 cmH(2)O) or only through the tracheal tube without any resistor. Hemodynamic and respiratory variables were measured during the breathing modes. Fluid responsiveness was defined as a 15% increase in stroke volume (ΔSV) following fluid loading. RESULTS: Stroke volume was significantly lower at hypovolemia compared with normovolemia, but no differences were found between normovolemia and 20% or 40% hypervolemia. Compared with breathing through no resistor, SPV was magnified by all resistors at hypovolemia whereas there were no changes at normovolemia and hypervolemia. PPV was magnified by the inspiratory resistor and the combined inspiratory and expiratory resistor. Regression analysis of SPV or PPV versus ΔSV showed the highest R(2 )(0.83 for SPV and 0.52 for PPV) when the expiratory resistor was applied. The corresponding sensitivity and specificity for prediction of fluid responsiveness were 100% and 100%, respectively, for SPV and 100% and 81%, respectively, for PPV. CONCLUSIONS: Inspiratory and/or expiratory threshold resistors magnified SPV and PPV in spontaneously breathing pigs during hypovolemia. Using the expiratory resistor SPV and PPV predicted fluid responsiveness with good sensitivity and specificity.
format Text
id pubmed-2689483
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-26894832009-06-02 Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study Dahl, Michael K Vistisen, Simon T Koefoed-Nielsen, Jacob Larsson, Anders Crit Care Research INTRODUCTION: Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypothesized that during spontaneous breathing, inspiratory and/or expiratory resistors could induce high arterial pressure variations at hypovolemia and low variations at normovolemia and hypervolemia. Furthermore, we hypothesized that SPV and PPV could predict fluid responsiveness under these conditions. METHODS: Eight prone, anesthetized and spontaneously breathing pigs (20 to 25 kg) were subjected to a sequence of 30% hypovolemia, normovolemia, and 20% and 40% hypervolemia. At each volemic level, the pigs breathed in a randomized order either through an inspiratory and/or an expiratory threshold resistor (7.5 cmH(2)O) or only through the tracheal tube without any resistor. Hemodynamic and respiratory variables were measured during the breathing modes. Fluid responsiveness was defined as a 15% increase in stroke volume (ΔSV) following fluid loading. RESULTS: Stroke volume was significantly lower at hypovolemia compared with normovolemia, but no differences were found between normovolemia and 20% or 40% hypervolemia. Compared with breathing through no resistor, SPV was magnified by all resistors at hypovolemia whereas there were no changes at normovolemia and hypervolemia. PPV was magnified by the inspiratory resistor and the combined inspiratory and expiratory resistor. Regression analysis of SPV or PPV versus ΔSV showed the highest R(2 )(0.83 for SPV and 0.52 for PPV) when the expiratory resistor was applied. The corresponding sensitivity and specificity for prediction of fluid responsiveness were 100% and 100%, respectively, for SPV and 100% and 81%, respectively, for PPV. CONCLUSIONS: Inspiratory and/or expiratory threshold resistors magnified SPV and PPV in spontaneously breathing pigs during hypovolemia. Using the expiratory resistor SPV and PPV predicted fluid responsiveness with good sensitivity and specificity. BioMed Central 2009 2009-03-20 /pmc/articles/PMC2689483/ /pubmed/19302700 http://dx.doi.org/10.1186/cc7760 Text en Copyright © 2009 Dahl et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Dahl, Michael K
Vistisen, Simon T
Koefoed-Nielsen, Jacob
Larsson, Anders
Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study
title Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study
title_full Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study
title_fullStr Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study
title_full_unstemmed Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study
title_short Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study
title_sort using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2689483/
https://www.ncbi.nlm.nih.gov/pubmed/19302700
http://dx.doi.org/10.1186/cc7760
work_keys_str_mv AT dahlmichaelk usinganexpiratoryresistorarterialpulsepressurevariationspredictfluidresponsivenessduringspontaneousbreathinganexperimentalporcinestudy
AT vistisensimont usinganexpiratoryresistorarterialpulsepressurevariationspredictfluidresponsivenessduringspontaneousbreathinganexperimentalporcinestudy
AT koefoednielsenjacob usinganexpiratoryresistorarterialpulsepressurevariationspredictfluidresponsivenessduringspontaneousbreathinganexperimentalporcinestudy
AT larssonanders usinganexpiratoryresistorarterialpulsepressurevariationspredictfluidresponsivenessduringspontaneousbreathinganexperimentalporcinestudy