Cargando…
Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome
INTRODUCTION: To investigate haemodynamic and respiratory changes during lung recruitment and decremental positive end-expiratory pressure (PEEP) titration for open lung ventilation in patients with acute respiratory distress syndrome (ARDS) a prospective, clinical trial was performed involving 12 a...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2689506/ https://www.ncbi.nlm.nih.gov/pubmed/19374751 http://dx.doi.org/10.1186/cc7786 |
_version_ | 1782167807116443648 |
---|---|
author | Gernoth, Christian Wagner, Gerhard Pelosi, Paolo Luecke, Thomas |
author_facet | Gernoth, Christian Wagner, Gerhard Pelosi, Paolo Luecke, Thomas |
author_sort | Gernoth, Christian |
collection | PubMed |
description | INTRODUCTION: To investigate haemodynamic and respiratory changes during lung recruitment and decremental positive end-expiratory pressure (PEEP) titration for open lung ventilation in patients with acute respiratory distress syndrome (ARDS) a prospective, clinical trial was performed involving 12 adult patients with ARDS treated in the surgical intensive care unit in a university hospital. METHODS: A software programme (Open Lung Tool™) incorporated into a standard ventilator controlled the recruitment (pressure-controlled ventilation with fixed PEEP at 20 cmH(2)O and increased driving pressures at 20, 25 and 30 cmH(2)O for two minutes each) and PEEP titration (PEEP lowered by 2 cmH(2)O every two minutes, with tidal volume set at 6 ml/kg). The open lung PEEP (OL-PEEP) was defined as the PEEP level yielding maximum dynamic respiratory compliance plus 2 cmH(2)O. Gas exchange, respiratory mechanics and central haemodynamics using the Pulse Contour Cardiac Output Monitor (PiCCO™), as well as transoesophageal echocardiography were measured at the following steps: at baseline (T(0)); during the final recruitment step with PEEP at 20 cmH(2)O and driving pressure at 30 cmH(2)O, (T(20/30)); at OL-PEEP, following another recruitment manoeuvre (T(OLP)). RESULTS: The ratio of partial pressure of arterial oxygen (PaO(2)) to fraction of inspired oxygen (FiO(2)) increased from T(0 )to T(OLP )(120 ± 59 versus 146 ± 64 mmHg, P < 0.005), as did dynamic respiratory compliance (23 ± 5 versus 27 ± 6 ml/cmH(2)O, P < 0.005). At constant PEEP (14 ± 3 cmH(2)O) and tidal volumes, peak inspiratory pressure decreased (32 ± 3 versus 29 ± 3 cmH(2)O, P < 0.005), although partial pressure of arterial carbon dioxide (PaCO(2)) was unchanged (58 ± 22 versus 53 ± 18 mmHg). No significant decrease in mean arterial pressure, stroke volume or cardiac output occurred during the recruitment (T(20/30)). However, left ventricular end-diastolic area decreased at T(20/30 )due to a decrease in the left ventricular end-diastolic septal-lateral diameter, while right ventricular end-diastolic area increased. Right ventricular function, estimated by the right ventricular Tei-index, deteriorated during the recruitment manoeuvre, but improved at T(OLP). CONCLUSIONS: A standardised open lung strategy increased oxygenation and improved respiratory system compliance. No major haemodynamic compromise was observed, although the increase in right ventricular Tei-index and right ventricular end-diastolic area and the decrease in left ventricular end-diastolic septal-lateral diameter during the recruitment suggested an increased right ventricular stress and strain. Right ventricular function was significantly improved at T(OLP )compared with T(0), although left ventricular function was unchanged, indicating effective lung volume optimisation. |
format | Text |
id | pubmed-2689506 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-26895062009-06-02 Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome Gernoth, Christian Wagner, Gerhard Pelosi, Paolo Luecke, Thomas Crit Care Research INTRODUCTION: To investigate haemodynamic and respiratory changes during lung recruitment and decremental positive end-expiratory pressure (PEEP) titration for open lung ventilation in patients with acute respiratory distress syndrome (ARDS) a prospective, clinical trial was performed involving 12 adult patients with ARDS treated in the surgical intensive care unit in a university hospital. METHODS: A software programme (Open Lung Tool™) incorporated into a standard ventilator controlled the recruitment (pressure-controlled ventilation with fixed PEEP at 20 cmH(2)O and increased driving pressures at 20, 25 and 30 cmH(2)O for two minutes each) and PEEP titration (PEEP lowered by 2 cmH(2)O every two minutes, with tidal volume set at 6 ml/kg). The open lung PEEP (OL-PEEP) was defined as the PEEP level yielding maximum dynamic respiratory compliance plus 2 cmH(2)O. Gas exchange, respiratory mechanics and central haemodynamics using the Pulse Contour Cardiac Output Monitor (PiCCO™), as well as transoesophageal echocardiography were measured at the following steps: at baseline (T(0)); during the final recruitment step with PEEP at 20 cmH(2)O and driving pressure at 30 cmH(2)O, (T(20/30)); at OL-PEEP, following another recruitment manoeuvre (T(OLP)). RESULTS: The ratio of partial pressure of arterial oxygen (PaO(2)) to fraction of inspired oxygen (FiO(2)) increased from T(0 )to T(OLP )(120 ± 59 versus 146 ± 64 mmHg, P < 0.005), as did dynamic respiratory compliance (23 ± 5 versus 27 ± 6 ml/cmH(2)O, P < 0.005). At constant PEEP (14 ± 3 cmH(2)O) and tidal volumes, peak inspiratory pressure decreased (32 ± 3 versus 29 ± 3 cmH(2)O, P < 0.005), although partial pressure of arterial carbon dioxide (PaCO(2)) was unchanged (58 ± 22 versus 53 ± 18 mmHg). No significant decrease in mean arterial pressure, stroke volume or cardiac output occurred during the recruitment (T(20/30)). However, left ventricular end-diastolic area decreased at T(20/30 )due to a decrease in the left ventricular end-diastolic septal-lateral diameter, while right ventricular end-diastolic area increased. Right ventricular function, estimated by the right ventricular Tei-index, deteriorated during the recruitment manoeuvre, but improved at T(OLP). CONCLUSIONS: A standardised open lung strategy increased oxygenation and improved respiratory system compliance. No major haemodynamic compromise was observed, although the increase in right ventricular Tei-index and right ventricular end-diastolic area and the decrease in left ventricular end-diastolic septal-lateral diameter during the recruitment suggested an increased right ventricular stress and strain. Right ventricular function was significantly improved at T(OLP )compared with T(0), although left ventricular function was unchanged, indicating effective lung volume optimisation. BioMed Central 2009 2009-04-17 /pmc/articles/PMC2689506/ /pubmed/19374751 http://dx.doi.org/10.1186/cc7786 Text en Copyright © 2009 Gernoth et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Gernoth, Christian Wagner, Gerhard Pelosi, Paolo Luecke, Thomas Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome |
title | Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome |
title_full | Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome |
title_fullStr | Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome |
title_full_unstemmed | Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome |
title_short | Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome |
title_sort | respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2689506/ https://www.ncbi.nlm.nih.gov/pubmed/19374751 http://dx.doi.org/10.1186/cc7786 |
work_keys_str_mv | AT gernothchristian respiratoryandhaemodynamicchangesduringdecrementalopenlungpositiveendexpiratorypressuretitrationinpatientswithacuterespiratorydistresssyndrome AT wagnergerhard respiratoryandhaemodynamicchangesduringdecrementalopenlungpositiveendexpiratorypressuretitrationinpatientswithacuterespiratorydistresssyndrome AT pelosipaolo respiratoryandhaemodynamicchangesduringdecrementalopenlungpositiveendexpiratorypressuretitrationinpatientswithacuterespiratorydistresssyndrome AT lueckethomas respiratoryandhaemodynamicchangesduringdecrementalopenlungpositiveendexpiratorypressuretitrationinpatientswithacuterespiratorydistresssyndrome |