Cargando…
Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents
PURPOSE: To investigate the immediate and long-term outcomes of Ahmed glaucoma valve (AGV) implantation with silicone tube ligation and removable external stents. METHODS: This retrospective non-comparative study investigated the outcomes of AGV implantation with silicone tube ligation and removable...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Ophthalmological Society
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694298/ https://www.ncbi.nlm.nih.gov/pubmed/19568356 http://dx.doi.org/10.3341/kjo.2009.23.2.86 |
_version_ | 1782168071751860224 |
---|---|
author | Lee, Jong Joo Park, Ki Ho Kim, Dong Myung Kim, Tae Woo |
author_facet | Lee, Jong Joo Park, Ki Ho Kim, Dong Myung Kim, Tae Woo |
author_sort | Lee, Jong Joo |
collection | PubMed |
description | PURPOSE: To investigate the immediate and long-term outcomes of Ahmed glaucoma valve (AGV) implantation with silicone tube ligation and removable external stents. METHODS: This retrospective non-comparative study investigated the outcomes of AGV implantation with silicone tube ligation and removable external stents in 95 eyes (90 patients) with at least 12 months of postoperative follow-up. Qualified success was defined as an intraocular pressure (IOP) of ≤21 mmHg and ≥6 mmHg regardless of anti-glaucoma medication. Those who required additional glaucoma surgery, implant removal or who had phthisis bulbi were considered failures. Hypotony was defined as an IOP of <6 mmHg. RESULTS: Mean IOP reduced from 37.1±9.7 mmHg preoperatively to 15.2±5.6 mmHg at 12 months postoperatively (p<0.001). Qualified success was achieved in 84.2% at 1 year. Hypotony with an IOP of <6 mmHg was seen in 8.4% and an IOP of <5 mmHg in 3.2% on the first postoperative day. No case of hypotony required surgical intervention. Suprachoroidal hemorrhage did not occur in this study. When stents were removed on the first postoperative day because of an insufficient IOP decrease, the mean IOP decreased significantly from 42.0 mmHg to 14.1 mmHg (p<0.001) after 1 hour. The most common complication was hyphema, which occurred in 17.9%. CONCLUSIONS: Hypotony-related early complications requiring surgical intervention were reduced by ligation and external stents in the tube. In addition, early postoperative high IOPs were managed by removing external stents. The described method can prevent postoperative hypotony after AGV implantation and showed long-term success rates comparable to those reported previously. |
format | Text |
id | pubmed-2694298 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | The Korean Ophthalmological Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-26942982009-07-01 Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents Lee, Jong Joo Park, Ki Ho Kim, Dong Myung Kim, Tae Woo Korean J Ophthalmol Original Article PURPOSE: To investigate the immediate and long-term outcomes of Ahmed glaucoma valve (AGV) implantation with silicone tube ligation and removable external stents. METHODS: This retrospective non-comparative study investigated the outcomes of AGV implantation with silicone tube ligation and removable external stents in 95 eyes (90 patients) with at least 12 months of postoperative follow-up. Qualified success was defined as an intraocular pressure (IOP) of ≤21 mmHg and ≥6 mmHg regardless of anti-glaucoma medication. Those who required additional glaucoma surgery, implant removal or who had phthisis bulbi were considered failures. Hypotony was defined as an IOP of <6 mmHg. RESULTS: Mean IOP reduced from 37.1±9.7 mmHg preoperatively to 15.2±5.6 mmHg at 12 months postoperatively (p<0.001). Qualified success was achieved in 84.2% at 1 year. Hypotony with an IOP of <6 mmHg was seen in 8.4% and an IOP of <5 mmHg in 3.2% on the first postoperative day. No case of hypotony required surgical intervention. Suprachoroidal hemorrhage did not occur in this study. When stents were removed on the first postoperative day because of an insufficient IOP decrease, the mean IOP decreased significantly from 42.0 mmHg to 14.1 mmHg (p<0.001) after 1 hour. The most common complication was hyphema, which occurred in 17.9%. CONCLUSIONS: Hypotony-related early complications requiring surgical intervention were reduced by ligation and external stents in the tube. In addition, early postoperative high IOPs were managed by removing external stents. The described method can prevent postoperative hypotony after AGV implantation and showed long-term success rates comparable to those reported previously. The Korean Ophthalmological Society 2009-06 2009-06-09 /pmc/articles/PMC2694298/ /pubmed/19568356 http://dx.doi.org/10.3341/kjo.2009.23.2.86 Text en Copyright © 2009 by the Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Jong Joo Park, Ki Ho Kim, Dong Myung Kim, Tae Woo Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents |
title | Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents |
title_full | Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents |
title_fullStr | Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents |
title_full_unstemmed | Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents |
title_short | Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents |
title_sort | clinical outcomes of ahmed glaucoma valve implantation using tube ligation and removable external stents |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694298/ https://www.ncbi.nlm.nih.gov/pubmed/19568356 http://dx.doi.org/10.3341/kjo.2009.23.2.86 |
work_keys_str_mv | AT leejongjoo clinicaloutcomesofahmedglaucomavalveimplantationusingtubeligationandremovableexternalstents AT parkkiho clinicaloutcomesofahmedglaucomavalveimplantationusingtubeligationandremovableexternalstents AT kimdongmyung clinicaloutcomesofahmedglaucomavalveimplantationusingtubeligationandremovableexternalstents AT kimtaewoo clinicaloutcomesofahmedglaucomavalveimplantationusingtubeligationandremovableexternalstents |