Cargando…

Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents

PURPOSE: To investigate the immediate and long-term outcomes of Ahmed glaucoma valve (AGV) implantation with silicone tube ligation and removable external stents. METHODS: This retrospective non-comparative study investigated the outcomes of AGV implantation with silicone tube ligation and removable...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jong Joo, Park, Ki Ho, Kim, Dong Myung, Kim, Tae Woo
Formato: Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694298/
https://www.ncbi.nlm.nih.gov/pubmed/19568356
http://dx.doi.org/10.3341/kjo.2009.23.2.86
_version_ 1782168071751860224
author Lee, Jong Joo
Park, Ki Ho
Kim, Dong Myung
Kim, Tae Woo
author_facet Lee, Jong Joo
Park, Ki Ho
Kim, Dong Myung
Kim, Tae Woo
author_sort Lee, Jong Joo
collection PubMed
description PURPOSE: To investigate the immediate and long-term outcomes of Ahmed glaucoma valve (AGV) implantation with silicone tube ligation and removable external stents. METHODS: This retrospective non-comparative study investigated the outcomes of AGV implantation with silicone tube ligation and removable external stents in 95 eyes (90 patients) with at least 12 months of postoperative follow-up. Qualified success was defined as an intraocular pressure (IOP) of ≤21 mmHg and ≥6 mmHg regardless of anti-glaucoma medication. Those who required additional glaucoma surgery, implant removal or who had phthisis bulbi were considered failures. Hypotony was defined as an IOP of <6 mmHg. RESULTS: Mean IOP reduced from 37.1±9.7 mmHg preoperatively to 15.2±5.6 mmHg at 12 months postoperatively (p<0.001). Qualified success was achieved in 84.2% at 1 year. Hypotony with an IOP of <6 mmHg was seen in 8.4% and an IOP of <5 mmHg in 3.2% on the first postoperative day. No case of hypotony required surgical intervention. Suprachoroidal hemorrhage did not occur in this study. When stents were removed on the first postoperative day because of an insufficient IOP decrease, the mean IOP decreased significantly from 42.0 mmHg to 14.1 mmHg (p<0.001) after 1 hour. The most common complication was hyphema, which occurred in 17.9%. CONCLUSIONS: Hypotony-related early complications requiring surgical intervention were reduced by ligation and external stents in the tube. In addition, early postoperative high IOPs were managed by removing external stents. The described method can prevent postoperative hypotony after AGV implantation and showed long-term success rates comparable to those reported previously.
format Text
id pubmed-2694298
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-26942982009-07-01 Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents Lee, Jong Joo Park, Ki Ho Kim, Dong Myung Kim, Tae Woo Korean J Ophthalmol Original Article PURPOSE: To investigate the immediate and long-term outcomes of Ahmed glaucoma valve (AGV) implantation with silicone tube ligation and removable external stents. METHODS: This retrospective non-comparative study investigated the outcomes of AGV implantation with silicone tube ligation and removable external stents in 95 eyes (90 patients) with at least 12 months of postoperative follow-up. Qualified success was defined as an intraocular pressure (IOP) of ≤21 mmHg and ≥6 mmHg regardless of anti-glaucoma medication. Those who required additional glaucoma surgery, implant removal or who had phthisis bulbi were considered failures. Hypotony was defined as an IOP of <6 mmHg. RESULTS: Mean IOP reduced from 37.1±9.7 mmHg preoperatively to 15.2±5.6 mmHg at 12 months postoperatively (p<0.001). Qualified success was achieved in 84.2% at 1 year. Hypotony with an IOP of <6 mmHg was seen in 8.4% and an IOP of <5 mmHg in 3.2% on the first postoperative day. No case of hypotony required surgical intervention. Suprachoroidal hemorrhage did not occur in this study. When stents were removed on the first postoperative day because of an insufficient IOP decrease, the mean IOP decreased significantly from 42.0 mmHg to 14.1 mmHg (p<0.001) after 1 hour. The most common complication was hyphema, which occurred in 17.9%. CONCLUSIONS: Hypotony-related early complications requiring surgical intervention were reduced by ligation and external stents in the tube. In addition, early postoperative high IOPs were managed by removing external stents. The described method can prevent postoperative hypotony after AGV implantation and showed long-term success rates comparable to those reported previously. The Korean Ophthalmological Society 2009-06 2009-06-09 /pmc/articles/PMC2694298/ /pubmed/19568356 http://dx.doi.org/10.3341/kjo.2009.23.2.86 Text en Copyright © 2009 by the Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Jong Joo
Park, Ki Ho
Kim, Dong Myung
Kim, Tae Woo
Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents
title Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents
title_full Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents
title_fullStr Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents
title_full_unstemmed Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents
title_short Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents
title_sort clinical outcomes of ahmed glaucoma valve implantation using tube ligation and removable external stents
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694298/
https://www.ncbi.nlm.nih.gov/pubmed/19568356
http://dx.doi.org/10.3341/kjo.2009.23.2.86
work_keys_str_mv AT leejongjoo clinicaloutcomesofahmedglaucomavalveimplantationusingtubeligationandremovableexternalstents
AT parkkiho clinicaloutcomesofahmedglaucomavalveimplantationusingtubeligationandremovableexternalstents
AT kimdongmyung clinicaloutcomesofahmedglaucomavalveimplantationusingtubeligationandremovableexternalstents
AT kimtaewoo clinicaloutcomesofahmedglaucomavalveimplantationusingtubeligationandremovableexternalstents