Cargando…
A Magnetic Resonance-based Seed Localization Method for I-125 Prostate Implants
This study was performed to develop and evaluate a semi-automatic seed localization algorithm from magnetic resonance (MR) images for interstitial prostate brachytherapy. The computerized tomography (CT) and MR images (3 mm-slice thickness) of six patients who had received real-time MR imaging-guide...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Medical Sciences
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694378/ https://www.ncbi.nlm.nih.gov/pubmed/17923739 http://dx.doi.org/10.3346/jkms.2007.22.S.S129 |
_version_ | 1782168082416926720 |
---|---|
author | Lee, Rena J. Suh, HyunSuk Lee, Kyung-Ja Lim, Soome Kim, Yookyung Kim, Sungkyu Choi, Jinho |
author_facet | Lee, Rena J. Suh, HyunSuk Lee, Kyung-Ja Lim, Soome Kim, Yookyung Kim, Sungkyu Choi, Jinho |
author_sort | Lee, Rena J. |
collection | PubMed |
description | This study was performed to develop and evaluate a semi-automatic seed localization algorithm from magnetic resonance (MR) images for interstitial prostate brachytherapy. The computerized tomography (CT) and MR images (3 mm-slice thickness) of six patients who had received real-time MR imaging-guided interstitial prostate brachytherapy were obtained. An automatic seed localization method was performed on CT images to obtain seed coordinates, and an algorithm for seed localization from MR images of the prostate was developed and tested. The resultant seed distributions from MR images were then compared to CT-derived distribution by matching the same seeds and calculating percent volume receiving 100% of the prescribed dose and the extent of the volume in 3-dimensions. The semiautomatic seed localization method made it possible to extract more than 90% of the seeds with either less than 8% of noises or 3% of missing seeds. The mean volume difference obtained from CT and MR receiving 100% of the prescribed dose was less than 3%. The maximum extent of the volume receiving the prescribed dose were 0.3, 0.6, and 0.2 cm in x, y, and z directions, respectively. These results indicate that the algorithm is very useful in identifying seeds from MR image for post-implant dosimety. |
format | Text |
id | pubmed-2694378 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | The Korean Academy of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-26943782009-06-11 A Magnetic Resonance-based Seed Localization Method for I-125 Prostate Implants Lee, Rena J. Suh, HyunSuk Lee, Kyung-Ja Lim, Soome Kim, Yookyung Kim, Sungkyu Choi, Jinho J Korean Med Sci Original Article This study was performed to develop and evaluate a semi-automatic seed localization algorithm from magnetic resonance (MR) images for interstitial prostate brachytherapy. The computerized tomography (CT) and MR images (3 mm-slice thickness) of six patients who had received real-time MR imaging-guided interstitial prostate brachytherapy were obtained. An automatic seed localization method was performed on CT images to obtain seed coordinates, and an algorithm for seed localization from MR images of the prostate was developed and tested. The resultant seed distributions from MR images were then compared to CT-derived distribution by matching the same seeds and calculating percent volume receiving 100% of the prescribed dose and the extent of the volume in 3-dimensions. The semiautomatic seed localization method made it possible to extract more than 90% of the seeds with either less than 8% of noises or 3% of missing seeds. The mean volume difference obtained from CT and MR receiving 100% of the prescribed dose was less than 3%. The maximum extent of the volume receiving the prescribed dose were 0.3, 0.6, and 0.2 cm in x, y, and z directions, respectively. These results indicate that the algorithm is very useful in identifying seeds from MR image for post-implant dosimety. The Korean Academy of Medical Sciences 2007-09 2007-09-30 /pmc/articles/PMC2694378/ /pubmed/17923739 http://dx.doi.org/10.3346/jkms.2007.22.S.S129 Text en Copyright © 2007 The Korean Academy of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Rena J. Suh, HyunSuk Lee, Kyung-Ja Lim, Soome Kim, Yookyung Kim, Sungkyu Choi, Jinho A Magnetic Resonance-based Seed Localization Method for I-125 Prostate Implants |
title | A Magnetic Resonance-based Seed Localization Method for I-125 Prostate Implants |
title_full | A Magnetic Resonance-based Seed Localization Method for I-125 Prostate Implants |
title_fullStr | A Magnetic Resonance-based Seed Localization Method for I-125 Prostate Implants |
title_full_unstemmed | A Magnetic Resonance-based Seed Localization Method for I-125 Prostate Implants |
title_short | A Magnetic Resonance-based Seed Localization Method for I-125 Prostate Implants |
title_sort | magnetic resonance-based seed localization method for i-125 prostate implants |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694378/ https://www.ncbi.nlm.nih.gov/pubmed/17923739 http://dx.doi.org/10.3346/jkms.2007.22.S.S129 |
work_keys_str_mv | AT leerenaj amagneticresonancebasedseedlocalizationmethodfori125prostateimplants AT suhhyunsuk amagneticresonancebasedseedlocalizationmethodfori125prostateimplants AT leekyungja amagneticresonancebasedseedlocalizationmethodfori125prostateimplants AT limsoome amagneticresonancebasedseedlocalizationmethodfori125prostateimplants AT kimyookyung amagneticresonancebasedseedlocalizationmethodfori125prostateimplants AT kimsungkyu amagneticresonancebasedseedlocalizationmethodfori125prostateimplants AT choijinho amagneticresonancebasedseedlocalizationmethodfori125prostateimplants AT leerenaj magneticresonancebasedseedlocalizationmethodfori125prostateimplants AT suhhyunsuk magneticresonancebasedseedlocalizationmethodfori125prostateimplants AT leekyungja magneticresonancebasedseedlocalizationmethodfori125prostateimplants AT limsoome magneticresonancebasedseedlocalizationmethodfori125prostateimplants AT kimyookyung magneticresonancebasedseedlocalizationmethodfori125prostateimplants AT kimsungkyu magneticresonancebasedseedlocalizationmethodfori125prostateimplants AT choijinho magneticresonancebasedseedlocalizationmethodfori125prostateimplants |