Cargando…

High Resolution Implantable Microsystem and Probe Design for Retinal Prosthesis

By a retinal prosthesis, the researchers have been able to stimulate a limited number of neurons (around 100) by biphasic current stimulus to reproduce an image spatially by multiplexing technique. For functional restoration of sight (visual acuity 20/80), we are to stimulate at least 2500 neurons/m...

Descripción completa

Detalles Bibliográficos
Autores principales: Talukder, Mohammad Ismail, Siy, Pepe, Auner, Gregory W
Formato: Texto
Lenguaje:English
Publicado: Bentham Open 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694608/
https://www.ncbi.nlm.nih.gov/pubmed/19516913
http://dx.doi.org/10.2174/1874364100802010077
_version_ 1782168104525103104
author Talukder, Mohammad Ismail
Siy, Pepe
Auner, Gregory W
author_facet Talukder, Mohammad Ismail
Siy, Pepe
Auner, Gregory W
author_sort Talukder, Mohammad Ismail
collection PubMed
description By a retinal prosthesis, the researchers have been able to stimulate a limited number of neurons (around 100) by biphasic current stimulus to reproduce an image spatially by multiplexing technique. For functional restoration of sight (visual acuity 20/80), we are to stimulate at least 2500 neurons/mm(2). We are far behind that target. The time required by biphasic current stimulus, the sequential stimulation by multiplexing technique, and the conventional probes used for stimulation limits our ability to stimulate large number of neurons and maintains the persistence of vision. To address this problem, we have designed high resolution donut probes and used them in designing neural implant chip (NIC) applying parallel multiplexing technique, which helped us stimulate large number of neurons. This paper presents the design of a donut probe and an implantable CMOS-based 5x5 array NIC to demonstrate that idea. This 5x5 array NIC is scalable to any larger array. It uses external clock, which makes it suitable for any data rate. The programmable biphasic width controller (BWC) used in this design is capable of generating various kinds of stimulus for stimulation. NIC doesn’t need address to route the pixels, which reduces the data transmission overhead. 0.5 µm CMOS technology is used to fabricate NIC with donut probes. Test results verify our technique of increasing the resolution.
format Text
id pubmed-2694608
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-26946082009-06-09 High Resolution Implantable Microsystem and Probe Design for Retinal Prosthesis Talukder, Mohammad Ismail Siy, Pepe Auner, Gregory W Open Ophthalmol J Article By a retinal prosthesis, the researchers have been able to stimulate a limited number of neurons (around 100) by biphasic current stimulus to reproduce an image spatially by multiplexing technique. For functional restoration of sight (visual acuity 20/80), we are to stimulate at least 2500 neurons/mm(2). We are far behind that target. The time required by biphasic current stimulus, the sequential stimulation by multiplexing technique, and the conventional probes used for stimulation limits our ability to stimulate large number of neurons and maintains the persistence of vision. To address this problem, we have designed high resolution donut probes and used them in designing neural implant chip (NIC) applying parallel multiplexing technique, which helped us stimulate large number of neurons. This paper presents the design of a donut probe and an implantable CMOS-based 5x5 array NIC to demonstrate that idea. This 5x5 array NIC is scalable to any larger array. It uses external clock, which makes it suitable for any data rate. The programmable biphasic width controller (BWC) used in this design is capable of generating various kinds of stimulus for stimulation. NIC doesn’t need address to route the pixels, which reduces the data transmission overhead. 0.5 µm CMOS technology is used to fabricate NIC with donut probes. Test results verify our technique of increasing the resolution. Bentham Open 2008-04-29 /pmc/articles/PMC2694608/ /pubmed/19516913 http://dx.doi.org/10.2174/1874364100802010077 Text en © Talukder et al.; Licensee Bentham Open. http://creativecommons.org/license/by/2.5/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/license/by/2.5/), which permits unrestrictive use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Article
Talukder, Mohammad Ismail
Siy, Pepe
Auner, Gregory W
High Resolution Implantable Microsystem and Probe Design for Retinal Prosthesis
title High Resolution Implantable Microsystem and Probe Design for Retinal Prosthesis
title_full High Resolution Implantable Microsystem and Probe Design for Retinal Prosthesis
title_fullStr High Resolution Implantable Microsystem and Probe Design for Retinal Prosthesis
title_full_unstemmed High Resolution Implantable Microsystem and Probe Design for Retinal Prosthesis
title_short High Resolution Implantable Microsystem and Probe Design for Retinal Prosthesis
title_sort high resolution implantable microsystem and probe design for retinal prosthesis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694608/
https://www.ncbi.nlm.nih.gov/pubmed/19516913
http://dx.doi.org/10.2174/1874364100802010077
work_keys_str_mv AT talukdermohammadismail highresolutionimplantablemicrosystemandprobedesignforretinalprosthesis
AT siypepe highresolutionimplantablemicrosystemandprobedesignforretinalprosthesis
AT aunergregoryw highresolutionimplantablemicrosystemandprobedesignforretinalprosthesis