Cargando…

Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up

OBJECTIVE: To determine, by means of long-term follow-up evaluation, the outcome and accuracy of stereotactic core-needle biopsy (SCNB) of non-mass calcifications observed at mammography, and to analyze the factors contributing to false-negative findings. MATERIALS AND METHODS: Using a 14-gauge need...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Boo-Kyung, Choe, Yeon Hyeon, Ko, Young-Hyeh, Nam, Seok-Jin, Kim, Jung-Han, Yang, Jung-Hyun
Formato: Texto
Lenguaje:English
Publicado: The Korean Radiological Society 2003
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698099/
https://www.ncbi.nlm.nih.gov/pubmed/14726638
http://dx.doi.org/10.3348/kjr.2003.4.4.217
_version_ 1782168373494284288
author Han, Boo-Kyung
Choe, Yeon Hyeon
Ko, Young-Hyeh
Nam, Seok-Jin
Kim, Jung-Han
Yang, Jung-Hyun
author_facet Han, Boo-Kyung
Choe, Yeon Hyeon
Ko, Young-Hyeh
Nam, Seok-Jin
Kim, Jung-Han
Yang, Jung-Hyun
author_sort Han, Boo-Kyung
collection PubMed
description OBJECTIVE: To determine, by means of long-term follow-up evaluation, the outcome and accuracy of stereotactic core-needle biopsy (SCNB) of non-mass calcifications observed at mammography, and to analyze the factors contributing to false-negative findings. MATERIALS AND METHODS: Using a 14-gauge needle, SCNB was performed in cases involving 271 non-mass calcified lesions observed at mammography in 267 patients aged 23-72 (mean, 47) years. We compared the SCNB results with those of long-term follow-up which included surgery, mammography performed for at least six months, and reference to Korean Cancer Registry listings. We investigated the retrieval rate for calcifications observed at specimen mammography and histologic evaluation, and determined the incidence rate of cancer, sensitivity, and the underestimation rate for SCNB. False-negative cases were evaluated in terms of their mammographic findings, the effect of the operators' experience, and the retrieval rate for calcifications. RESULTS: For specimen mammography and histologic evaluation of SCNB, the retrieval rate for calcifications was, respectively, 84% and 77%. At SCNB, 54 of 271 lesions (19.9%) were malignant [carcinoma in situ, 45/54 (83%)], 16 were borderline, and 201 were benign. SCNB showed that the incidence of cancer was 5.0% (6/120) in the benign mammographic category and 31.8% (48/151) in the malignant category. The findings revealed by immediate surgery and by long-term follow-up showed, respectively, that the sensitivity of SCNB was 90% and 82%. For borderline lesions, the underestimation rate was 10%. For false-negative cases, which were more frequent among the first ten cases we studied (p = 0.01), the most frequent mammographic finding was clustered amorphous calcifications. For true-negative and false-negative cases, the retrieval rate for calcifications was similar at specimen mammography (83% and 67%, respectively; p = 0.14) and histologic evaluation (79% and 75%, respectively; p = 0.47). CONCLUSION: In this study group, most diagnosed cancers were in-situ lesions, and long-term follow-up showed that the sensitivity of SCNB was 82%. False-negative findings were frequent during the operators' learning period.
format Text
id pubmed-2698099
institution National Center for Biotechnology Information
language English
publishDate 2003
publisher The Korean Radiological Society
record_format MEDLINE/PubMed
spelling pubmed-26980992009-06-23 Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up Han, Boo-Kyung Choe, Yeon Hyeon Ko, Young-Hyeh Nam, Seok-Jin Kim, Jung-Han Yang, Jung-Hyun Korean J Radiol Original Article OBJECTIVE: To determine, by means of long-term follow-up evaluation, the outcome and accuracy of stereotactic core-needle biopsy (SCNB) of non-mass calcifications observed at mammography, and to analyze the factors contributing to false-negative findings. MATERIALS AND METHODS: Using a 14-gauge needle, SCNB was performed in cases involving 271 non-mass calcified lesions observed at mammography in 267 patients aged 23-72 (mean, 47) years. We compared the SCNB results with those of long-term follow-up which included surgery, mammography performed for at least six months, and reference to Korean Cancer Registry listings. We investigated the retrieval rate for calcifications observed at specimen mammography and histologic evaluation, and determined the incidence rate of cancer, sensitivity, and the underestimation rate for SCNB. False-negative cases were evaluated in terms of their mammographic findings, the effect of the operators' experience, and the retrieval rate for calcifications. RESULTS: For specimen mammography and histologic evaluation of SCNB, the retrieval rate for calcifications was, respectively, 84% and 77%. At SCNB, 54 of 271 lesions (19.9%) were malignant [carcinoma in situ, 45/54 (83%)], 16 were borderline, and 201 were benign. SCNB showed that the incidence of cancer was 5.0% (6/120) in the benign mammographic category and 31.8% (48/151) in the malignant category. The findings revealed by immediate surgery and by long-term follow-up showed, respectively, that the sensitivity of SCNB was 90% and 82%. For borderline lesions, the underestimation rate was 10%. For false-negative cases, which were more frequent among the first ten cases we studied (p = 0.01), the most frequent mammographic finding was clustered amorphous calcifications. For true-negative and false-negative cases, the retrieval rate for calcifications was similar at specimen mammography (83% and 67%, respectively; p = 0.14) and histologic evaluation (79% and 75%, respectively; p = 0.47). CONCLUSION: In this study group, most diagnosed cancers were in-situ lesions, and long-term follow-up showed that the sensitivity of SCNB was 82%. False-negative findings were frequent during the operators' learning period. The Korean Radiological Society 2003 2003-12-31 /pmc/articles/PMC2698099/ /pubmed/14726638 http://dx.doi.org/10.3348/kjr.2003.4.4.217 Text en Copyright © 2003 The Korean Radiological Society http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Han, Boo-Kyung
Choe, Yeon Hyeon
Ko, Young-Hyeh
Nam, Seok-Jin
Kim, Jung-Han
Yang, Jung-Hyun
Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up
title Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up
title_full Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up
title_fullStr Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up
title_full_unstemmed Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up
title_short Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-Up
title_sort stereotactic core-needle biopsy of non-mass calcifications: outcome and accuracy at long-term follow-up
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698099/
https://www.ncbi.nlm.nih.gov/pubmed/14726638
http://dx.doi.org/10.3348/kjr.2003.4.4.217
work_keys_str_mv AT hanbookyung stereotacticcoreneedlebiopsyofnonmasscalcificationsoutcomeandaccuracyatlongtermfollowup
AT choeyeonhyeon stereotacticcoreneedlebiopsyofnonmasscalcificationsoutcomeandaccuracyatlongtermfollowup
AT koyounghyeh stereotacticcoreneedlebiopsyofnonmasscalcificationsoutcomeandaccuracyatlongtermfollowup
AT namseokjin stereotacticcoreneedlebiopsyofnonmasscalcificationsoutcomeandaccuracyatlongtermfollowup
AT kimjunghan stereotacticcoreneedlebiopsyofnonmasscalcificationsoutcomeandaccuracyatlongtermfollowup
AT yangjunghyun stereotacticcoreneedlebiopsyofnonmasscalcificationsoutcomeandaccuracyatlongtermfollowup