Cargando…

Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen

Enhanced z-axis coverage with thin overlapping slices in breath-hold acquisitions with multidetector CT (MDCT) has considerably enhanced the quality of multiplanar 3D reconstruction. This pictorial essay describes the improvements in 3D reconstruction and technical aspects of 3D reconstruction and r...

Descripción completa

Detalles Bibliográficos
Autores principales: Maher, Michael M., Kalra, Mannudeep K., Sahani, Dushyant V., Perumpillichira, James J., Rizzo, Stephania, Saini, Sanjay, Mueller, Peter R.
Formato: Texto
Lenguaje:English
Publicado: The Korean Radiological Society 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698114/
https://www.ncbi.nlm.nih.gov/pubmed/15064560
http://dx.doi.org/10.3348/kjr.2004.5.1.55
_version_ 1782168377043714048
author Maher, Michael M.
Kalra, Mannudeep K.
Sahani, Dushyant V.
Perumpillichira, James J.
Rizzo, Stephania
Saini, Sanjay
Mueller, Peter R.
author_facet Maher, Michael M.
Kalra, Mannudeep K.
Sahani, Dushyant V.
Perumpillichira, James J.
Rizzo, Stephania
Saini, Sanjay
Mueller, Peter R.
author_sort Maher, Michael M.
collection PubMed
description Enhanced z-axis coverage with thin overlapping slices in breath-hold acquisitions with multidetector CT (MDCT) has considerably enhanced the quality of multiplanar 3D reconstruction. This pictorial essay describes the improvements in 3D reconstruction and technical aspects of 3D reconstruction and rendering techniques available for abdominal imaging. Clinical applications of 3D imaging in abdomen including liver, pancreaticobiliary system, urinary and gastrointestinal tracts and imaging before and after transplantation are discussed. In addition, this article briefly discusses the disadvantages of thin-slice acquisitions including increasing numbers of transverse images, which must be reviewed by the radiologist.
format Text
id pubmed-2698114
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher The Korean Radiological Society
record_format MEDLINE/PubMed
spelling pubmed-26981142009-06-23 Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen Maher, Michael M. Kalra, Mannudeep K. Sahani, Dushyant V. Perumpillichira, James J. Rizzo, Stephania Saini, Sanjay Mueller, Peter R. Korean J Radiol Pictorial Essay Enhanced z-axis coverage with thin overlapping slices in breath-hold acquisitions with multidetector CT (MDCT) has considerably enhanced the quality of multiplanar 3D reconstruction. This pictorial essay describes the improvements in 3D reconstruction and technical aspects of 3D reconstruction and rendering techniques available for abdominal imaging. Clinical applications of 3D imaging in abdomen including liver, pancreaticobiliary system, urinary and gastrointestinal tracts and imaging before and after transplantation are discussed. In addition, this article briefly discusses the disadvantages of thin-slice acquisitions including increasing numbers of transverse images, which must be reviewed by the radiologist. The Korean Radiological Society 2004 2004-03-31 /pmc/articles/PMC2698114/ /pubmed/15064560 http://dx.doi.org/10.3348/kjr.2004.5.1.55 Text en Copyright © 2004 The Korean Radiological Society http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Pictorial Essay
Maher, Michael M.
Kalra, Mannudeep K.
Sahani, Dushyant V.
Perumpillichira, James J.
Rizzo, Stephania
Saini, Sanjay
Mueller, Peter R.
Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen
title Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen
title_full Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen
title_fullStr Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen
title_full_unstemmed Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen
title_short Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen
title_sort techniques, clinical applications and limitations of 3d reconstruction in ct of the abdomen
topic Pictorial Essay
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698114/
https://www.ncbi.nlm.nih.gov/pubmed/15064560
http://dx.doi.org/10.3348/kjr.2004.5.1.55
work_keys_str_mv AT mahermichaelm techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen
AT kalramannudeepk techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen
AT sahanidushyantv techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen
AT perumpillichirajamesj techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen
AT rizzostephania techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen
AT sainisanjay techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen
AT muellerpeterr techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen