Cargando…
Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen
Enhanced z-axis coverage with thin overlapping slices in breath-hold acquisitions with multidetector CT (MDCT) has considerably enhanced the quality of multiplanar 3D reconstruction. This pictorial essay describes the improvements in 3D reconstruction and technical aspects of 3D reconstruction and r...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Radiological Society
2004
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698114/ https://www.ncbi.nlm.nih.gov/pubmed/15064560 http://dx.doi.org/10.3348/kjr.2004.5.1.55 |
_version_ | 1782168377043714048 |
---|---|
author | Maher, Michael M. Kalra, Mannudeep K. Sahani, Dushyant V. Perumpillichira, James J. Rizzo, Stephania Saini, Sanjay Mueller, Peter R. |
author_facet | Maher, Michael M. Kalra, Mannudeep K. Sahani, Dushyant V. Perumpillichira, James J. Rizzo, Stephania Saini, Sanjay Mueller, Peter R. |
author_sort | Maher, Michael M. |
collection | PubMed |
description | Enhanced z-axis coverage with thin overlapping slices in breath-hold acquisitions with multidetector CT (MDCT) has considerably enhanced the quality of multiplanar 3D reconstruction. This pictorial essay describes the improvements in 3D reconstruction and technical aspects of 3D reconstruction and rendering techniques available for abdominal imaging. Clinical applications of 3D imaging in abdomen including liver, pancreaticobiliary system, urinary and gastrointestinal tracts and imaging before and after transplantation are discussed. In addition, this article briefly discusses the disadvantages of thin-slice acquisitions including increasing numbers of transverse images, which must be reviewed by the radiologist. |
format | Text |
id | pubmed-2698114 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2004 |
publisher | The Korean Radiological Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-26981142009-06-23 Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen Maher, Michael M. Kalra, Mannudeep K. Sahani, Dushyant V. Perumpillichira, James J. Rizzo, Stephania Saini, Sanjay Mueller, Peter R. Korean J Radiol Pictorial Essay Enhanced z-axis coverage with thin overlapping slices in breath-hold acquisitions with multidetector CT (MDCT) has considerably enhanced the quality of multiplanar 3D reconstruction. This pictorial essay describes the improvements in 3D reconstruction and technical aspects of 3D reconstruction and rendering techniques available for abdominal imaging. Clinical applications of 3D imaging in abdomen including liver, pancreaticobiliary system, urinary and gastrointestinal tracts and imaging before and after transplantation are discussed. In addition, this article briefly discusses the disadvantages of thin-slice acquisitions including increasing numbers of transverse images, which must be reviewed by the radiologist. The Korean Radiological Society 2004 2004-03-31 /pmc/articles/PMC2698114/ /pubmed/15064560 http://dx.doi.org/10.3348/kjr.2004.5.1.55 Text en Copyright © 2004 The Korean Radiological Society http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Pictorial Essay Maher, Michael M. Kalra, Mannudeep K. Sahani, Dushyant V. Perumpillichira, James J. Rizzo, Stephania Saini, Sanjay Mueller, Peter R. Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen |
title | Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen |
title_full | Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen |
title_fullStr | Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen |
title_full_unstemmed | Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen |
title_short | Techniques, Clinical Applications and Limitations of 3D Reconstruction in CT of the Abdomen |
title_sort | techniques, clinical applications and limitations of 3d reconstruction in ct of the abdomen |
topic | Pictorial Essay |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698114/ https://www.ncbi.nlm.nih.gov/pubmed/15064560 http://dx.doi.org/10.3348/kjr.2004.5.1.55 |
work_keys_str_mv | AT mahermichaelm techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen AT kalramannudeepk techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen AT sahanidushyantv techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen AT perumpillichirajamesj techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen AT rizzostephania techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen AT sainisanjay techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen AT muellerpeterr techniquesclinicalapplicationsandlimitationsof3dreconstructioninctoftheabdomen |