Cargando…

Optimization of Wet Radiofrequency Ablation Using a Perfused-Cooled Electrode: A Comparative Study in Ex Vivo Bovine Livers

OBJECTIVE: To determine the optimized protocol for wet monopolar radiofrequency ablation (RFA) using a perfused-cooled electrode to induce coagulation necrosis in the ex vivo bovine liver. MATERIALS AND METHODS: Radiofrequency was applied to excised bovine livers in a monopolar mode using a 200W gen...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jeong Min, Han, Joon Koo, Kim, Se Hyung, Lee, Jae Young, Shin, Kyung Sook, Han, Chang Jin, Lee, Min Woo, Choi, Jun Il, Choi, Byung Ihn
Formato: Texto
Lenguaje:English
Publicado: The Korean Radiological Society 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698169/
https://www.ncbi.nlm.nih.gov/pubmed/15637475
http://dx.doi.org/10.3348/kjr.2004.5.4.250
_version_ 1782168387715072000
author Lee, Jeong Min
Han, Joon Koo
Kim, Se Hyung
Lee, Jae Young
Shin, Kyung Sook
Han, Chang Jin
Lee, Min Woo
Choi, Jun Il
Choi, Byung Ihn
author_facet Lee, Jeong Min
Han, Joon Koo
Kim, Se Hyung
Lee, Jae Young
Shin, Kyung Sook
Han, Chang Jin
Lee, Min Woo
Choi, Jun Il
Choi, Byung Ihn
author_sort Lee, Jeong Min
collection PubMed
description OBJECTIVE: To determine the optimized protocol for wet monopolar radiofrequency ablation (RFA) using a perfused-cooled electrode to induce coagulation necrosis in the ex vivo bovine liver. MATERIALS AND METHODS: Radiofrequency was applied to excised bovine livers in a monopolar mode using a 200W generator with an internally cooled electrode (groups A and B) or a perfused-cooled electrode (groups C, D, E, and F) at maximum power (150-200 W) for 10 minutes. A total of 60 ablation zones were created with six different regimens: group A - dry RFA using intra-electrode cooling; group B - dry RFA using intra-electrode cooling and a pulsing algorithm; group C - wet RFA using only interstitial hypertonic saline (HS) infusion; group D - wet RFA using interstitial HS infusion and a pulsing algorithm; group E - wet RFA using interstitial HS infusion and intra-electrode cooling; and group F - wet RFA using interstitial HS infusion, intra-electrode cooling and a pulsing algorithm. In groups C, D, E, and F, RFA was performed with the infusion of 6% HS through the perfused cooled electrode at a rate of 2 mL/minute. During RFA, we measured the tissue temperature at a distance of 15 mm from the electrode. The dimensions of the ablation zones and the changes in impedance, currents, and liver temperature during RFA were compared between these six groups. RESULTS: During RFA, the mean tissue impedances in groups A (243 ± 88 Ω) and C (252.5 ± 108 Ω) were significantly higher than those in groups B (85 ± 18.7 Ω), D (108.2 ± 85 Ω), E (70.0 ± 16.3 Ω), and F (66.5 ± 7 Ω) (p < 0.05). The mean currents in groups E and F were significantly higher than those in groups B and D, which were significantly higher than those in groups A and C (p < 0.05): 520 ± 425 mA in group A, 1163 ± 34 mA in group B, 652.5 ± 418 mA in group C, 842.5 ± 773 mA in group D, 1665 ± 295 mA in group E, and 1830 ± 109 mA in group F. The mean volumes of the ablation regions in groups E and F were significantly larger than those in the other groups (p < 0.05): 17.7 ± 5.6 cm(3) in group A, 34.5 ± 3.0 cm(3) in group B, 20.2 ± 15.6 cm(3) in group C, 36.1 ± 19.5 cm(3) in group D, 68.1 ± 12.4 cm(3) in group E, and 79.5 ± 31 cm(3) in group F. The final tissue temperatures at a distance of 15 mm from the electrode were higher in groups E and F than those in groups A, C, and D (p < 0.05): 50 ± 7.5℃ in group A, 66 ± 13.6℃ in group B, 60 ± 13.4℃ in group C, 61 ±12.7℃ in group D, 78 ± 14.2℃ in group E, and 79 ± 12.0℃ in group F. CONCLUSION: Wet monopolar RFA, using intra-electrode cooling and interstitial saline infusion, showed better performance in creating a large ablation zone than either dry RFA or wet RFA without intra-electrode cooling.
format Text
id pubmed-2698169
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher The Korean Radiological Society
record_format MEDLINE/PubMed
spelling pubmed-26981692009-06-23 Optimization of Wet Radiofrequency Ablation Using a Perfused-Cooled Electrode: A Comparative Study in Ex Vivo Bovine Livers Lee, Jeong Min Han, Joon Koo Kim, Se Hyung Lee, Jae Young Shin, Kyung Sook Han, Chang Jin Lee, Min Woo Choi, Jun Il Choi, Byung Ihn Korean J Radiol Original Article OBJECTIVE: To determine the optimized protocol for wet monopolar radiofrequency ablation (RFA) using a perfused-cooled electrode to induce coagulation necrosis in the ex vivo bovine liver. MATERIALS AND METHODS: Radiofrequency was applied to excised bovine livers in a monopolar mode using a 200W generator with an internally cooled electrode (groups A and B) or a perfused-cooled electrode (groups C, D, E, and F) at maximum power (150-200 W) for 10 minutes. A total of 60 ablation zones were created with six different regimens: group A - dry RFA using intra-electrode cooling; group B - dry RFA using intra-electrode cooling and a pulsing algorithm; group C - wet RFA using only interstitial hypertonic saline (HS) infusion; group D - wet RFA using interstitial HS infusion and a pulsing algorithm; group E - wet RFA using interstitial HS infusion and intra-electrode cooling; and group F - wet RFA using interstitial HS infusion, intra-electrode cooling and a pulsing algorithm. In groups C, D, E, and F, RFA was performed with the infusion of 6% HS through the perfused cooled electrode at a rate of 2 mL/minute. During RFA, we measured the tissue temperature at a distance of 15 mm from the electrode. The dimensions of the ablation zones and the changes in impedance, currents, and liver temperature during RFA were compared between these six groups. RESULTS: During RFA, the mean tissue impedances in groups A (243 ± 88 Ω) and C (252.5 ± 108 Ω) were significantly higher than those in groups B (85 ± 18.7 Ω), D (108.2 ± 85 Ω), E (70.0 ± 16.3 Ω), and F (66.5 ± 7 Ω) (p < 0.05). The mean currents in groups E and F were significantly higher than those in groups B and D, which were significantly higher than those in groups A and C (p < 0.05): 520 ± 425 mA in group A, 1163 ± 34 mA in group B, 652.5 ± 418 mA in group C, 842.5 ± 773 mA in group D, 1665 ± 295 mA in group E, and 1830 ± 109 mA in group F. The mean volumes of the ablation regions in groups E and F were significantly larger than those in the other groups (p < 0.05): 17.7 ± 5.6 cm(3) in group A, 34.5 ± 3.0 cm(3) in group B, 20.2 ± 15.6 cm(3) in group C, 36.1 ± 19.5 cm(3) in group D, 68.1 ± 12.4 cm(3) in group E, and 79.5 ± 31 cm(3) in group F. The final tissue temperatures at a distance of 15 mm from the electrode were higher in groups E and F than those in groups A, C, and D (p < 0.05): 50 ± 7.5℃ in group A, 66 ± 13.6℃ in group B, 60 ± 13.4℃ in group C, 61 ±12.7℃ in group D, 78 ± 14.2℃ in group E, and 79 ± 12.0℃ in group F. CONCLUSION: Wet monopolar RFA, using intra-electrode cooling and interstitial saline infusion, showed better performance in creating a large ablation zone than either dry RFA or wet RFA without intra-electrode cooling. The Korean Radiological Society 2004 2004-12-31 /pmc/articles/PMC2698169/ /pubmed/15637475 http://dx.doi.org/10.3348/kjr.2004.5.4.250 Text en Copyright © 2004 The Korean Radiological Society http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Jeong Min
Han, Joon Koo
Kim, Se Hyung
Lee, Jae Young
Shin, Kyung Sook
Han, Chang Jin
Lee, Min Woo
Choi, Jun Il
Choi, Byung Ihn
Optimization of Wet Radiofrequency Ablation Using a Perfused-Cooled Electrode: A Comparative Study in Ex Vivo Bovine Livers
title Optimization of Wet Radiofrequency Ablation Using a Perfused-Cooled Electrode: A Comparative Study in Ex Vivo Bovine Livers
title_full Optimization of Wet Radiofrequency Ablation Using a Perfused-Cooled Electrode: A Comparative Study in Ex Vivo Bovine Livers
title_fullStr Optimization of Wet Radiofrequency Ablation Using a Perfused-Cooled Electrode: A Comparative Study in Ex Vivo Bovine Livers
title_full_unstemmed Optimization of Wet Radiofrequency Ablation Using a Perfused-Cooled Electrode: A Comparative Study in Ex Vivo Bovine Livers
title_short Optimization of Wet Radiofrequency Ablation Using a Perfused-Cooled Electrode: A Comparative Study in Ex Vivo Bovine Livers
title_sort optimization of wet radiofrequency ablation using a perfused-cooled electrode: a comparative study in ex vivo bovine livers
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698169/
https://www.ncbi.nlm.nih.gov/pubmed/15637475
http://dx.doi.org/10.3348/kjr.2004.5.4.250
work_keys_str_mv AT leejeongmin optimizationofwetradiofrequencyablationusingaperfusedcooledelectrodeacomparativestudyinexvivobovinelivers
AT hanjoonkoo optimizationofwetradiofrequencyablationusingaperfusedcooledelectrodeacomparativestudyinexvivobovinelivers
AT kimsehyung optimizationofwetradiofrequencyablationusingaperfusedcooledelectrodeacomparativestudyinexvivobovinelivers
AT leejaeyoung optimizationofwetradiofrequencyablationusingaperfusedcooledelectrodeacomparativestudyinexvivobovinelivers
AT shinkyungsook optimizationofwetradiofrequencyablationusingaperfusedcooledelectrodeacomparativestudyinexvivobovinelivers
AT hanchangjin optimizationofwetradiofrequencyablationusingaperfusedcooledelectrodeacomparativestudyinexvivobovinelivers
AT leeminwoo optimizationofwetradiofrequencyablationusingaperfusedcooledelectrodeacomparativestudyinexvivobovinelivers
AT choijunil optimizationofwetradiofrequencyablationusingaperfusedcooledelectrodeacomparativestudyinexvivobovinelivers
AT choibyungihn optimizationofwetradiofrequencyablationusingaperfusedcooledelectrodeacomparativestudyinexvivobovinelivers