Cargando…

Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma

PURPOSE: To describe clinical findings after Ahmed valve drainage implantation in children. DESIGN: All records in one practice were reviewed to identify and describe clinical findings in all children who had undergone Ahmed Glaucoma Valve™ S2 model insertion for uncontrolled primary or secondary gl...

Descripción completa

Detalles Bibliográficos
Autores principales: Pirouzian, Amir, Demer, Joseph L
Formato: Texto
Lenguaje:English
Publicado: Dove Medical Press 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698676/
https://www.ncbi.nlm.nih.gov/pubmed/19668395
_version_ 1782168409150062592
author Pirouzian, Amir
Demer, Joseph L
author_facet Pirouzian, Amir
Demer, Joseph L
author_sort Pirouzian, Amir
collection PubMed
description PURPOSE: To describe clinical findings after Ahmed valve drainage implantation in children. DESIGN: All records in one practice were reviewed to identify and describe clinical findings in all children who had undergone Ahmed Glaucoma Valve™ S2 model insertion for uncontrolled primary or secondary glaucoma. RESULTS: A total of 6 patients were identified, ranging in age from 2–15 years. Mean follow-up time averaged from 2–5 years from the time of tube insertion. Three patients exhibited pupillary peaking towards the tube of the valve. All patients required additional surgery or additional medications to control intraocular pressure. Lenticular opacification near the tube site developed in one patient. Gradual tube extrusion was also noted in another two patients. CONCLUSION: Multiple clinical events follow the Ahmed valve insertion in children. Pupillary irregularity is the most commonly noted event in this series. To avoid or reduce the risk of this complication, additional or modification of surgical procedures could be considered. The mechanism of such occurrence will further be discussed.
format Text
id pubmed-2698676
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-26986762009-08-10 Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma Pirouzian, Amir Demer, Joseph L Clin Ophthalmol Original Research PURPOSE: To describe clinical findings after Ahmed valve drainage implantation in children. DESIGN: All records in one practice were reviewed to identify and describe clinical findings in all children who had undergone Ahmed Glaucoma Valve™ S2 model insertion for uncontrolled primary or secondary glaucoma. RESULTS: A total of 6 patients were identified, ranging in age from 2–15 years. Mean follow-up time averaged from 2–5 years from the time of tube insertion. Three patients exhibited pupillary peaking towards the tube of the valve. All patients required additional surgery or additional medications to control intraocular pressure. Lenticular opacification near the tube site developed in one patient. Gradual tube extrusion was also noted in another two patients. CONCLUSION: Multiple clinical events follow the Ahmed valve insertion in children. Pupillary irregularity is the most commonly noted event in this series. To avoid or reduce the risk of this complication, additional or modification of surgical procedures could be considered. The mechanism of such occurrence will further be discussed. Dove Medical Press 2008-03 /pmc/articles/PMC2698676/ /pubmed/19668395 Text en © 2008 Pirouzian and Demer publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Pirouzian, Amir
Demer, Joseph L
Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma
title Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma
title_full Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma
title_fullStr Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma
title_full_unstemmed Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma
title_short Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma
title_sort clinical findings following ahmed glaucoma valve™ implantation in pediatric glaucoma
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698676/
https://www.ncbi.nlm.nih.gov/pubmed/19668395
work_keys_str_mv AT pirouzianamir clinicalfindingsfollowingahmedglaucomavalveimplantationinpediatricglaucoma
AT demerjosephl clinicalfindingsfollowingahmedglaucomavalveimplantationinpediatricglaucoma