Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation

BACKGROUND: Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration...

Descripción completa

Detalles Bibliográficos
Autores principales: Kouvidis, George K, Sommers, Mark B, Giannoudis, Peter V, Katonis, Pavlos G, Bottlang, Michael
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698912/
https://www.ncbi.nlm.nih.gov/pubmed/19450283
http://dx.doi.org/10.1186/1749-799X-4-16
_version_ 1782168436636385280
author Kouvidis, George K
Sommers, Mark B
Giannoudis, Peter V
Katonis, Pavlos G
Bottlang, Michael
author_facet Kouvidis, George K
Sommers, Mark B
Giannoudis, Peter V
Katonis, Pavlos G
Bottlang, Michael
author_sort Kouvidis, George K
collection PubMed
description BACKGROUND: Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration behavior and cut-out resistance of a single and a dual lag screw implant were comparatively evaluated in surrogate specimens using an established laboratory model of hip screw cut-out failure. METHODS: Five dual lag screw implants (Endovis, Citieffe) and five single lag screw implants (DHS, Synthes) were tested in the Hip Implant Performance Simulator (HIPS) of the Legacy Biomechanics Laboratory. This model simulated osteoporotic bone, an unstable fracture, and biaxial rocking motion representative of hip loading during normal gait. All constructs were loaded up to 20,000 cycles of 1.45 kN peak magnitude under biaxial rocking motion. The migration kinematics was continuously monitored with 6-degrees of freedom motion tracking system and the number of cycles to implant cut-out was recorded. RESULTS: The dual lag screw implant exhibited significantly less migration and sustained more loading cycles in comparison to the DHS single lag screw. All DHS constructs failed before 20,000 cycles, on average at 6,638 ± 2,837 cycles either by cut-out or permanent screw bending. At failure, DHS constructs exhibited 10.8 ± 2.3° varus collapse and 15.5 ± 9.5° rotation around the lag screw axis. Four out of five dual screws constructs sustained 20,000 loading cycles. One dual screw specimens sustained cut-out by medial migration of the distal screw after 10,054 cycles. At test end, varus collapse and neck rotation in dual screws implants advanced to 3.7 ± 1.7° and 1.6 ± 1.0°, respectively. CONCLUSION: The single and double lag screw implants demonstrated a significantly different migration resistance in surrogate specimens under gait loading simulation with the HIPS model. In this model, the double screw construct provided significantly greater resistance against varus collapse and neck rotation in comparison to a standard DHS lag screw implant.
format Text
id pubmed-2698912
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-26989122009-06-19 Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation Kouvidis, George K Sommers, Mark B Giannoudis, Peter V Katonis, Pavlos G Bottlang, Michael J Orthop Surg Res Research Article BACKGROUND: Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration behavior and cut-out resistance of a single and a dual lag screw implant were comparatively evaluated in surrogate specimens using an established laboratory model of hip screw cut-out failure. METHODS: Five dual lag screw implants (Endovis, Citieffe) and five single lag screw implants (DHS, Synthes) were tested in the Hip Implant Performance Simulator (HIPS) of the Legacy Biomechanics Laboratory. This model simulated osteoporotic bone, an unstable fracture, and biaxial rocking motion representative of hip loading during normal gait. All constructs were loaded up to 20,000 cycles of 1.45 kN peak magnitude under biaxial rocking motion. The migration kinematics was continuously monitored with 6-degrees of freedom motion tracking system and the number of cycles to implant cut-out was recorded. RESULTS: The dual lag screw implant exhibited significantly less migration and sustained more loading cycles in comparison to the DHS single lag screw. All DHS constructs failed before 20,000 cycles, on average at 6,638 ± 2,837 cycles either by cut-out or permanent screw bending. At failure, DHS constructs exhibited 10.8 ± 2.3° varus collapse and 15.5 ± 9.5° rotation around the lag screw axis. Four out of five dual screws constructs sustained 20,000 loading cycles. One dual screw specimens sustained cut-out by medial migration of the distal screw after 10,054 cycles. At test end, varus collapse and neck rotation in dual screws implants advanced to 3.7 ± 1.7° and 1.6 ± 1.0°, respectively. CONCLUSION: The single and double lag screw implants demonstrated a significantly different migration resistance in surrogate specimens under gait loading simulation with the HIPS model. In this model, the double screw construct provided significantly greater resistance against varus collapse and neck rotation in comparison to a standard DHS lag screw implant. BioMed Central 2009-05-18 /pmc/articles/PMC2698912/ /pubmed/19450283 http://dx.doi.org/10.1186/1749-799X-4-16 Text en Copyright © 2009 Kouvidis et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Kouvidis, George K
Sommers, Mark B
Giannoudis, Peter V
Katonis, Pavlos G
Bottlang, Michael
Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation
title Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation
title_full Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation
title_fullStr Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation
title_full_unstemmed Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation
title_short Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation
title_sort comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2698912/
https://www.ncbi.nlm.nih.gov/pubmed/19450283
http://dx.doi.org/10.1186/1749-799X-4-16
work_keys_str_mv AT kouvidisgeorgek comparisonofmigrationbehaviorbetweensingleandduallagscrewimplantsforintertrochantericfracturefixation
AT sommersmarkb comparisonofmigrationbehaviorbetweensingleandduallagscrewimplantsforintertrochantericfracturefixation
AT giannoudispeterv comparisonofmigrationbehaviorbetweensingleandduallagscrewimplantsforintertrochantericfracturefixation
AT katonispavlosg comparisonofmigrationbehaviorbetweensingleandduallagscrewimplantsforintertrochantericfracturefixation
AT bottlangmichael comparisonofmigrationbehaviorbetweensingleandduallagscrewimplantsforintertrochantericfracturefixation