Cargando…
Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies
A simple, specific, sensitive, and rapid high performance liquid chromatography (HPLC) method for the determination of griseofulvin in small volumes of rat plasma was developed and validated using warfarin as an internal standard. Biological sample preparation involved simple extraction with acetoni...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Libertas Academica
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2701169/ https://www.ncbi.nlm.nih.gov/pubmed/19609394 |
_version_ | 1782168680449179648 |
---|---|
author | Wei, Bo Liang, Dong Bates, Theodore R. |
author_facet | Wei, Bo Liang, Dong Bates, Theodore R. |
author_sort | Wei, Bo |
collection | PubMed |
description | A simple, specific, sensitive, and rapid high performance liquid chromatography (HPLC) method for the determination of griseofulvin in small volumes of rat plasma was developed and validated using warfarin as an internal standard. Biological sample preparation involved simple extraction with acetonitrile, followed by dilution with aqueous mobile phase buffer (20 mM sodium dihydrogen phosphate, pH 3.5) to eliminate any chromatographic solvent effects. Griseofulvin and warfarin were baseline separated and quantitated on a C(18) reversed phase column (4.6 × 150 mm, 3.5 μm), using a mobile phase composed of a 20 mM aqueous solution of sodium dihydrogen phosphate-acetonitrile (55:45, v/v, pH 3.5) delivered at a flow rate of 1.0 mL/min, and with fluorescence detection (λexcitation = 300 nm, λ(emission) = 418 nm). The method was proven to be linear over a plasma griseofulvin concentration range of 10 to 2500 ng/mL with a mean correlation coefficient of 0.9996. The intra-day and inter-day accuracy (relative error) were in the range of 0.89% to 9.26% and 0.71% to 7.68%, respectively. The within-day precision (coefficient of variation) was less than 3.0% and the between-day precision was less than 7.5%. The mean recovery of griseofulvin from rat plasma was found to be 99.2%. The limit of detection (LOD) and the limit of quantification (LOQ) of griseofulvin were determined to be 1 ng/mL and 10 ng/mL, respectively. The developed method was successfully applied to quantitatively assess the pharmacokinetics of griseofulvin in rats following a single 50 mg/kg oral dose of the drug. |
format | Text |
id | pubmed-2701169 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Libertas Academica |
record_format | MEDLINE/PubMed |
spelling | pubmed-27011692009-07-16 Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies Wei, Bo Liang, Dong Bates, Theodore R. Anal Chem Insights Original Research A simple, specific, sensitive, and rapid high performance liquid chromatography (HPLC) method for the determination of griseofulvin in small volumes of rat plasma was developed and validated using warfarin as an internal standard. Biological sample preparation involved simple extraction with acetonitrile, followed by dilution with aqueous mobile phase buffer (20 mM sodium dihydrogen phosphate, pH 3.5) to eliminate any chromatographic solvent effects. Griseofulvin and warfarin were baseline separated and quantitated on a C(18) reversed phase column (4.6 × 150 mm, 3.5 μm), using a mobile phase composed of a 20 mM aqueous solution of sodium dihydrogen phosphate-acetonitrile (55:45, v/v, pH 3.5) delivered at a flow rate of 1.0 mL/min, and with fluorescence detection (λexcitation = 300 nm, λ(emission) = 418 nm). The method was proven to be linear over a plasma griseofulvin concentration range of 10 to 2500 ng/mL with a mean correlation coefficient of 0.9996. The intra-day and inter-day accuracy (relative error) were in the range of 0.89% to 9.26% and 0.71% to 7.68%, respectively. The within-day precision (coefficient of variation) was less than 3.0% and the between-day precision was less than 7.5%. The mean recovery of griseofulvin from rat plasma was found to be 99.2%. The limit of detection (LOD) and the limit of quantification (LOQ) of griseofulvin were determined to be 1 ng/mL and 10 ng/mL, respectively. The developed method was successfully applied to quantitatively assess the pharmacokinetics of griseofulvin in rats following a single 50 mg/kg oral dose of the drug. Libertas Academica 2008-08-27 /pmc/articles/PMC2701169/ /pubmed/19609394 Text en Copyright © 2008 The authors. http://creativecommons.org/licenses/by/3.0 This article is published under the Creative Commons Attribution By licence. For further information go to: http://creativecommons.org/licenses/by/3.0. (http://creativecommons.org/licenses/by/3.0) |
spellingShingle | Original Research Wei, Bo Liang, Dong Bates, Theodore R. Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies |
title | Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies |
title_full | Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies |
title_fullStr | Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies |
title_full_unstemmed | Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies |
title_short | Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies |
title_sort | development and validation of a hplc method to determine griseofulvin in rat plasma: application to pharmacokinetic studies |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2701169/ https://www.ncbi.nlm.nih.gov/pubmed/19609394 |
work_keys_str_mv | AT weibo developmentandvalidationofahplcmethodtodeterminegriseofulvininratplasmaapplicationtopharmacokineticstudies AT liangdong developmentandvalidationofahplcmethodtodeterminegriseofulvininratplasmaapplicationtopharmacokineticstudies AT batestheodorer developmentandvalidationofahplcmethodtodeterminegriseofulvininratplasmaapplicationtopharmacokineticstudies |