Cargando…

Tracheal replacement by autogenous aorta

BACKGROUND: Tracheal defects may occur after trauma or prolonged intubation. Resection of tracheal tumors also poses a major challenge for substitution. In an effort to solve this problem, different techniques have been tried with little success. We report on a new animal model which showed acceptab...

Descripción completa

Detalles Bibliográficos
Autores principales: Anoosh, Farhad, Hodjati, Hossain, Dehghani, Seifollah, Tanideh, Nader, Kumar, Perikala V
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2701424/
https://www.ncbi.nlm.nih.gov/pubmed/19508714
http://dx.doi.org/10.1186/1749-8090-4-23
_version_ 1782168698044284928
author Anoosh, Farhad
Hodjati, Hossain
Dehghani, Seifollah
Tanideh, Nader
Kumar, Perikala V
author_facet Anoosh, Farhad
Hodjati, Hossain
Dehghani, Seifollah
Tanideh, Nader
Kumar, Perikala V
author_sort Anoosh, Farhad
collection PubMed
description BACKGROUND: Tracheal defects may occur after trauma or prolonged intubation. Resection of tracheal tumors also poses a major challenge for substitution. In an effort to solve this problem, different techniques have been tried with little success. We report on a new animal model which showed acceptable results with fewer complications. METHODS: We replaced 5 cm of cervical trachea in 10 dogs with harvested infra-renal aorta and repaired the aortic defect with Dacron graft. RESULTS: Necropsy of the grafted aorta and anastomotic site revealed well healed anastomosis in all animals together with ciliated columnar epithelium coverage of grafted aorta and neovascularization of aortic wall. CONCLUSION: Aortic graft is preferable to other substitutes because of less antigenicity, less vascularity, and no mucous secretions or peristalsis
format Text
id pubmed-2701424
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-27014242009-06-25 Tracheal replacement by autogenous aorta Anoosh, Farhad Hodjati, Hossain Dehghani, Seifollah Tanideh, Nader Kumar, Perikala V J Cardiothorac Surg Research Article BACKGROUND: Tracheal defects may occur after trauma or prolonged intubation. Resection of tracheal tumors also poses a major challenge for substitution. In an effort to solve this problem, different techniques have been tried with little success. We report on a new animal model which showed acceptable results with fewer complications. METHODS: We replaced 5 cm of cervical trachea in 10 dogs with harvested infra-renal aorta and repaired the aortic defect with Dacron graft. RESULTS: Necropsy of the grafted aorta and anastomotic site revealed well healed anastomosis in all animals together with ciliated columnar epithelium coverage of grafted aorta and neovascularization of aortic wall. CONCLUSION: Aortic graft is preferable to other substitutes because of less antigenicity, less vascularity, and no mucous secretions or peristalsis BioMed Central 2009-06-09 /pmc/articles/PMC2701424/ /pubmed/19508714 http://dx.doi.org/10.1186/1749-8090-4-23 Text en Copyright © 2009 Anoosh et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Anoosh, Farhad
Hodjati, Hossain
Dehghani, Seifollah
Tanideh, Nader
Kumar, Perikala V
Tracheal replacement by autogenous aorta
title Tracheal replacement by autogenous aorta
title_full Tracheal replacement by autogenous aorta
title_fullStr Tracheal replacement by autogenous aorta
title_full_unstemmed Tracheal replacement by autogenous aorta
title_short Tracheal replacement by autogenous aorta
title_sort tracheal replacement by autogenous aorta
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2701424/
https://www.ncbi.nlm.nih.gov/pubmed/19508714
http://dx.doi.org/10.1186/1749-8090-4-23
work_keys_str_mv AT anooshfarhad trachealreplacementbyautogenousaorta
AT hodjatihossain trachealreplacementbyautogenousaorta
AT dehghaniseifollah trachealreplacementbyautogenousaorta
AT tanidehnader trachealreplacementbyautogenousaorta
AT kumarperikalav trachealreplacementbyautogenousaorta