Comparative study of imaging at 3.0 T versus 1.5 T of the knee

PURPOSE: The objectives of the study were to compare MR imaging at 1.5 and 3.0 T in the same patients concerning image quality and visualization of cartilage pathology and to assess diagnostic performance using arthroscopy as a standard of reference. MATERIALS AND METHODS: Twenty-six patients were i...

Descripción completa

Detalles Bibliográficos
Autores principales: Wong, Scott, Steinbach, Lynne, Zhao, Jian, Stehling, Christoph, Ma, C. Benjamin, Link, Thomas M.
Formato: Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2704948/
https://www.ncbi.nlm.nih.gov/pubmed/19350234
http://dx.doi.org/10.1007/s00256-009-0683-0
_version_ 1782168955121565696
author Wong, Scott
Steinbach, Lynne
Zhao, Jian
Stehling, Christoph
Ma, C. Benjamin
Link, Thomas M.
author_facet Wong, Scott
Steinbach, Lynne
Zhao, Jian
Stehling, Christoph
Ma, C. Benjamin
Link, Thomas M.
author_sort Wong, Scott
collection PubMed
description PURPOSE: The objectives of the study were to compare MR imaging at 1.5 and 3.0 T in the same patients concerning image quality and visualization of cartilage pathology and to assess diagnostic performance using arthroscopy as a standard of reference. MATERIALS AND METHODS: Twenty-six patients were identified retrospectively as having comparative 1.5 and 3.0 T MR studies of the knee within an average of 102 days. Standard protocols included T1-weighted and fat-saturated intermediate-weighted fast spin-echo sequences in three planes; sequence parameters had been adjusted to account for differences in relaxation at 3.0 T. Arthroscopy was performed in 19 patients. Four radiologists reviewed each study independently, scored image quality, and analyzed pathological findings. Sensitivities, specificities, and accuracies in diagnosing cartilage lesions were calculated in the 19 patients with arthroscopy, and differences between 1.5 and 3.0 T exams were compared using paired Student’s t tests with a significance threshold of p < 0.05. RESULTS: Each radiologist scored the 3.0 T studies higher than those obtained at 1.5 T in visualizing anatomical structures and abnormalities (p < 0.05). Using arthroscopy as a standard of reference, diagnosis of cartilage abnormalities was improved at 3.0 T with higher sensitivity (75.7% versus 70.6%), accuracy (88.2% versus 86.4%), and correct grading of cartilage lesions (51.3% versus 42.9%). Diagnostic confidence scores were higher at 3.0 than 1.5 T (p < 0.05) and signal-to-noise ratio at 3.0 T was approximately twofold higher than at 1.5 T. CONCLUSION: MRI at 3.0 T improved visualization of anatomical structures and improved diagnostic confidence compared to 1.5 T. This resulted in significantly better sensitivity and grading of cartilage lesions at the knee.
format Text
id pubmed-2704948
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-27049482009-07-02 Comparative study of imaging at 3.0 T versus 1.5 T of the knee Wong, Scott Steinbach, Lynne Zhao, Jian Stehling, Christoph Ma, C. Benjamin Link, Thomas M. Skeletal Radiol Scientific Article PURPOSE: The objectives of the study were to compare MR imaging at 1.5 and 3.0 T in the same patients concerning image quality and visualization of cartilage pathology and to assess diagnostic performance using arthroscopy as a standard of reference. MATERIALS AND METHODS: Twenty-six patients were identified retrospectively as having comparative 1.5 and 3.0 T MR studies of the knee within an average of 102 days. Standard protocols included T1-weighted and fat-saturated intermediate-weighted fast spin-echo sequences in three planes; sequence parameters had been adjusted to account for differences in relaxation at 3.0 T. Arthroscopy was performed in 19 patients. Four radiologists reviewed each study independently, scored image quality, and analyzed pathological findings. Sensitivities, specificities, and accuracies in diagnosing cartilage lesions were calculated in the 19 patients with arthroscopy, and differences between 1.5 and 3.0 T exams were compared using paired Student’s t tests with a significance threshold of p < 0.05. RESULTS: Each radiologist scored the 3.0 T studies higher than those obtained at 1.5 T in visualizing anatomical structures and abnormalities (p < 0.05). Using arthroscopy as a standard of reference, diagnosis of cartilage abnormalities was improved at 3.0 T with higher sensitivity (75.7% versus 70.6%), accuracy (88.2% versus 86.4%), and correct grading of cartilage lesions (51.3% versus 42.9%). Diagnostic confidence scores were higher at 3.0 than 1.5 T (p < 0.05) and signal-to-noise ratio at 3.0 T was approximately twofold higher than at 1.5 T. CONCLUSION: MRI at 3.0 T improved visualization of anatomical structures and improved diagnostic confidence compared to 1.5 T. This resulted in significantly better sensitivity and grading of cartilage lesions at the knee. Springer Berlin Heidelberg 2009-04-07 2009 /pmc/articles/PMC2704948/ /pubmed/19350234 http://dx.doi.org/10.1007/s00256-009-0683-0 Text en © The Author(s) 2009 Open AccessThis is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License (https://creativecommons.org/licenses/by-nc/2.0), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Scientific Article
Wong, Scott
Steinbach, Lynne
Zhao, Jian
Stehling, Christoph
Ma, C. Benjamin
Link, Thomas M.
Comparative study of imaging at 3.0 T versus 1.5 T of the knee
title Comparative study of imaging at 3.0 T versus 1.5 T of the knee
title_full Comparative study of imaging at 3.0 T versus 1.5 T of the knee
title_fullStr Comparative study of imaging at 3.0 T versus 1.5 T of the knee
title_full_unstemmed Comparative study of imaging at 3.0 T versus 1.5 T of the knee
title_short Comparative study of imaging at 3.0 T versus 1.5 T of the knee
title_sort comparative study of imaging at 3.0 t versus 1.5 t of the knee
topic Scientific Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2704948/
https://www.ncbi.nlm.nih.gov/pubmed/19350234
http://dx.doi.org/10.1007/s00256-009-0683-0
work_keys_str_mv AT wongscott comparativestudyofimagingat30tversus15toftheknee
AT steinbachlynne comparativestudyofimagingat30tversus15toftheknee
AT zhaojian comparativestudyofimagingat30tversus15toftheknee
AT stehlingchristoph comparativestudyofimagingat30tversus15toftheknee
AT macbenjamin comparativestudyofimagingat30tversus15toftheknee
AT linkthomasm comparativestudyofimagingat30tversus15toftheknee