Cargando…
Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint
OBJECTIVE: The objectives of the study were to optimize three cartilage-dedicated sequences for in vivo knee imaging at 7.0 T ultra-high-field (UHF) magnetic resonance imaging (MRI) and to compare imaging performance and diagnostic confidence concerning osteoarthritis (OA)-induced changes at 7.0 and...
Autores principales: | , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2704950/ https://www.ncbi.nlm.nih.gov/pubmed/19294379 http://dx.doi.org/10.1007/s00256-009-0676-z |
_version_ | 1782168955594473472 |
---|---|
author | Stahl, Robert Krug, Roland Kelley, Douglas A. C. Zuo, Jin Ma, C. Benjamin Majumdar, Sharmila Link, Thomas M. |
author_facet | Stahl, Robert Krug, Roland Kelley, Douglas A. C. Zuo, Jin Ma, C. Benjamin Majumdar, Sharmila Link, Thomas M. |
author_sort | Stahl, Robert |
collection | PubMed |
description | OBJECTIVE: The objectives of the study were to optimize three cartilage-dedicated sequences for in vivo knee imaging at 7.0 T ultra-high-field (UHF) magnetic resonance imaging (MRI) and to compare imaging performance and diagnostic confidence concerning osteoarthritis (OA)-induced changes at 7.0 and 3.0 T MRI. MATERIALS AND METHODS: Optimized MRI sequences for cartilage imaging at 3.0 T were tailored for 7.0 T: an intermediate-weighted fast spin-echo (IM-w FSE), a fast imaging employing steady-state acquisition (FIESTA) and a T1-weighted 3D high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) sequence. Three healthy subjects and seven patients with mild OA were examined. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diagnostic confidence in assessing cartilage abnormalities, and image quality were determined. Abnormalities were assessed with the whole organ magnetic resonance imaging score (WORMS). Focal cartilage lesions and bone marrow edema pattern (BMEP) were also quantified. RESULTS: At 7.0 T, SNR was increased (p < 0.05) for all sequences. For the IM-w FSE sequence, limitations with the specific absorption rate (SAR) required modifications of the scan parameters yielding an incomplete coverage of the knee joint, extensive artifacts, and a less effective fat saturation. CNR and image quality were increased (p < 0.05) for SPGR and FIESTA and decreased for IM-w FSE. Diagnostic confidence for cartilage lesions was highest (p < 0.05) for FIESTA at 7.0 T. Evaluation of BMEP was decreased (p < 0.05) at 7.0 T due to limited performance of IM-w FSE. CONCLUSION: Gradient echo-based pulse sequences like SPGR and FIESTA are well suited for imaging at UHF which may improve early detection of cartilage lesions. However, UHF IM-w FSE sequences are less feasible for clinical use. |
format | Text |
id | pubmed-2704950 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-27049502009-07-02 Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint Stahl, Robert Krug, Roland Kelley, Douglas A. C. Zuo, Jin Ma, C. Benjamin Majumdar, Sharmila Link, Thomas M. Skeletal Radiol Scientific Article OBJECTIVE: The objectives of the study were to optimize three cartilage-dedicated sequences for in vivo knee imaging at 7.0 T ultra-high-field (UHF) magnetic resonance imaging (MRI) and to compare imaging performance and diagnostic confidence concerning osteoarthritis (OA)-induced changes at 7.0 and 3.0 T MRI. MATERIALS AND METHODS: Optimized MRI sequences for cartilage imaging at 3.0 T were tailored for 7.0 T: an intermediate-weighted fast spin-echo (IM-w FSE), a fast imaging employing steady-state acquisition (FIESTA) and a T1-weighted 3D high-spatial-resolution volumetric fat-suppressed spoiled gradient-echo (SPGR) sequence. Three healthy subjects and seven patients with mild OA were examined. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diagnostic confidence in assessing cartilage abnormalities, and image quality were determined. Abnormalities were assessed with the whole organ magnetic resonance imaging score (WORMS). Focal cartilage lesions and bone marrow edema pattern (BMEP) were also quantified. RESULTS: At 7.0 T, SNR was increased (p < 0.05) for all sequences. For the IM-w FSE sequence, limitations with the specific absorption rate (SAR) required modifications of the scan parameters yielding an incomplete coverage of the knee joint, extensive artifacts, and a less effective fat saturation. CNR and image quality were increased (p < 0.05) for SPGR and FIESTA and decreased for IM-w FSE. Diagnostic confidence for cartilage lesions was highest (p < 0.05) for FIESTA at 7.0 T. Evaluation of BMEP was decreased (p < 0.05) at 7.0 T due to limited performance of IM-w FSE. CONCLUSION: Gradient echo-based pulse sequences like SPGR and FIESTA are well suited for imaging at UHF which may improve early detection of cartilage lesions. However, UHF IM-w FSE sequences are less feasible for clinical use. Springer Berlin Heidelberg 2009-03-18 2009 /pmc/articles/PMC2704950/ /pubmed/19294379 http://dx.doi.org/10.1007/s00256-009-0676-z Text en © The Author(s) 2009 Open AccessThis is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License (https://creativecommons.org/licenses/by-nc/2.0), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Scientific Article Stahl, Robert Krug, Roland Kelley, Douglas A. C. Zuo, Jin Ma, C. Benjamin Majumdar, Sharmila Link, Thomas M. Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint |
title | Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint |
title_full | Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint |
title_fullStr | Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint |
title_full_unstemmed | Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint |
title_short | Assessment of cartilage-dedicated sequences at ultra-high-field MRI: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 T with respect to osteoarthritis-induced changes at the knee joint |
title_sort | assessment of cartilage-dedicated sequences at ultra-high-field mri: comparison of imaging performance and diagnostic confidence between 3.0 and 7.0 t with respect to osteoarthritis-induced changes at the knee joint |
topic | Scientific Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2704950/ https://www.ncbi.nlm.nih.gov/pubmed/19294379 http://dx.doi.org/10.1007/s00256-009-0676-z |
work_keys_str_mv | AT stahlrobert assessmentofcartilagededicatedsequencesatultrahighfieldmricomparisonofimagingperformanceanddiagnosticconfidencebetween30and70twithrespecttoosteoarthritisinducedchangesatthekneejoint AT krugroland assessmentofcartilagededicatedsequencesatultrahighfieldmricomparisonofimagingperformanceanddiagnosticconfidencebetween30and70twithrespecttoosteoarthritisinducedchangesatthekneejoint AT kelleydouglasac assessmentofcartilagededicatedsequencesatultrahighfieldmricomparisonofimagingperformanceanddiagnosticconfidencebetween30and70twithrespecttoosteoarthritisinducedchangesatthekneejoint AT zuojin assessmentofcartilagededicatedsequencesatultrahighfieldmricomparisonofimagingperformanceanddiagnosticconfidencebetween30and70twithrespecttoosteoarthritisinducedchangesatthekneejoint AT macbenjamin assessmentofcartilagededicatedsequencesatultrahighfieldmricomparisonofimagingperformanceanddiagnosticconfidencebetween30and70twithrespecttoosteoarthritisinducedchangesatthekneejoint AT majumdarsharmila assessmentofcartilagededicatedsequencesatultrahighfieldmricomparisonofimagingperformanceanddiagnosticconfidencebetween30and70twithrespecttoosteoarthritisinducedchangesatthekneejoint AT linkthomasm assessmentofcartilagededicatedsequencesatultrahighfieldmricomparisonofimagingperformanceanddiagnosticconfidencebetween30and70twithrespecttoosteoarthritisinducedchangesatthekneejoint |