Cargando…

Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses

BACKGROUND: To compare intracavitary brachytherapy (ICBT) planning methods for cervical cancer, based on either orthogonal radiographs (conventional plan) or CT sections (CT plan); the comparison focused on target volume coverage and dose volume analysis of organs at risk (OARs), by representing poi...

Descripción completa

Detalles Bibliográficos
Autores principales: Onal, Cem, Arslan, Gungor, Topkan, Erkan, Pehlivan, Berrin, Yavuz, Melek, Oymak, Ezgi, Yavuz, Aydin
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2711061/
https://www.ncbi.nlm.nih.gov/pubmed/19570212
http://dx.doi.org/10.1186/1756-9966-28-95
_version_ 1782169403060649984
author Onal, Cem
Arslan, Gungor
Topkan, Erkan
Pehlivan, Berrin
Yavuz, Melek
Oymak, Ezgi
Yavuz, Aydin
author_facet Onal, Cem
Arslan, Gungor
Topkan, Erkan
Pehlivan, Berrin
Yavuz, Melek
Oymak, Ezgi
Yavuz, Aydin
author_sort Onal, Cem
collection PubMed
description BACKGROUND: To compare intracavitary brachytherapy (ICBT) planning methods for cervical cancer, based on either orthogonal radiographs (conventional plan) or CT sections (CT plan); the comparison focused on target volume coverage and dose volume analysis of organs at risk (OARs), by representing point doses defined by the International Commission on Radiation Units and Measurement (ICRU) and dose volume histograms (DVHs) from 3D planning. METHODS: We analyzed the dosimetric data for 62 conventional and CT-based ICBT plans. The gross tumor volume (GTV), clinical target volume (CTV) and organs at risk (OAR)s were contoured on the CT-plan. Point A and ICRU 38 rectal and bladder points were defined on reconstructed CT images. RESULTS: Patients were categorized on the basis of whether the >95% isodose line of the point-A prescription dose encompassed the CTV (group 1, n = 24) or not (group 2, n = 38). The mean GTV and CTV (8.1 cc and 20.6 cc) were smaller in group 1 than in group 2 (24.7 cc and 48.4 cc) (P <0.001). The mean percentage of GTV and CTV coverage with the 7 Gy isodose was 93.1% and 88.2% for all patients, and decreased with increasing tumor size and stage. The mean D2 and D5 rectum doses were 1.66 and 1.42 times higher than the corresponding ICRU point doses and the mean D2 and D5 bladder doses were 1.51 and 1.28 times higher. The differences between the ICRU dose and the D2 and D5 doses were significantly higher in group 2 than in group 1 for the bladder, but not for the rectum. CONCLUSION: The CT-plan is superior to the conventional plan in target volume coverage and appropriate evaluation of OARs, as the conventional plan overestimates tumor doses and underestimates OAR doses.
format Text
id pubmed-2711061
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-27110612009-07-16 Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses Onal, Cem Arslan, Gungor Topkan, Erkan Pehlivan, Berrin Yavuz, Melek Oymak, Ezgi Yavuz, Aydin J Exp Clin Cancer Res Research BACKGROUND: To compare intracavitary brachytherapy (ICBT) planning methods for cervical cancer, based on either orthogonal radiographs (conventional plan) or CT sections (CT plan); the comparison focused on target volume coverage and dose volume analysis of organs at risk (OARs), by representing point doses defined by the International Commission on Radiation Units and Measurement (ICRU) and dose volume histograms (DVHs) from 3D planning. METHODS: We analyzed the dosimetric data for 62 conventional and CT-based ICBT plans. The gross tumor volume (GTV), clinical target volume (CTV) and organs at risk (OAR)s were contoured on the CT-plan. Point A and ICRU 38 rectal and bladder points were defined on reconstructed CT images. RESULTS: Patients were categorized on the basis of whether the >95% isodose line of the point-A prescription dose encompassed the CTV (group 1, n = 24) or not (group 2, n = 38). The mean GTV and CTV (8.1 cc and 20.6 cc) were smaller in group 1 than in group 2 (24.7 cc and 48.4 cc) (P <0.001). The mean percentage of GTV and CTV coverage with the 7 Gy isodose was 93.1% and 88.2% for all patients, and decreased with increasing tumor size and stage. The mean D2 and D5 rectum doses were 1.66 and 1.42 times higher than the corresponding ICRU point doses and the mean D2 and D5 bladder doses were 1.51 and 1.28 times higher. The differences between the ICRU dose and the D2 and D5 doses were significantly higher in group 2 than in group 1 for the bladder, but not for the rectum. CONCLUSION: The CT-plan is superior to the conventional plan in target volume coverage and appropriate evaluation of OARs, as the conventional plan overestimates tumor doses and underestimates OAR doses. BioMed Central 2009-07-01 /pmc/articles/PMC2711061/ /pubmed/19570212 http://dx.doi.org/10.1186/1756-9966-28-95 Text en Copyright © 2009 Onal et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Onal, Cem
Arslan, Gungor
Topkan, Erkan
Pehlivan, Berrin
Yavuz, Melek
Oymak, Ezgi
Yavuz, Aydin
Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_full Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_fullStr Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_full_unstemmed Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_short Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_sort comparison of conventional and ct-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2711061/
https://www.ncbi.nlm.nih.gov/pubmed/19570212
http://dx.doi.org/10.1186/1756-9966-28-95
work_keys_str_mv AT onalcem comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT arslangungor comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT topkanerkan comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT pehlivanberrin comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT yavuzmelek comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT oymakezgi comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT yavuzaydin comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses