Cargando…
The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters
OBJECTIVE: To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. MATERIALS AND METHODS: Four objects with different surfaces and contour...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Radiological Society
2002
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2713987/ https://www.ncbi.nlm.nih.gov/pubmed/11919479 http://dx.doi.org/10.3348/kjr.2002.3.1.49 |
_version_ | 1782169621394096128 |
---|---|
author | Shin, Ji Hoon Lee, Ho Kyu Choi, Choong Gon Suh, Dae Chul Lim, Tae-Hwan Kang, Weechang |
author_facet | Shin, Ji Hoon Lee, Ho Kyu Choi, Choong Gon Suh, Dae Chul Lim, Tae-Hwan Kang, Weechang |
author_sort | Shin, Ji Hoon |
collection | PubMed |
description | OBJECTIVE: To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. MATERIALS AND METHODS: Four objects with different surfaces and contours were scanned using multidetector-row helical CT at three detector-row collimations (1.25, 2.50, 5.00 mm), two pitches (3.0, 6.0), and three different degrees of overlap between the reconstructed slices (0%, 25%, 50%). Reconstructed 3D images of the resulting 72 sets of data were produced using volumetric rendering. The 72 images were graded on a scale from 1 (worst) to 5 (best) for each of four rating criteria, giving a mean score for each criterion and an overall mean score. Statistical analysis was used to assess differences in image quality according to scanning parameter levels. RESULTS: The mean score for each rating criterion, and the overall mean score, varied significantly according to the scanning parameter levels used. With regard to detector-row collimation and pitch, all levels of scanning parameters gave rise to significant differences, while in the degree of overlap of reconstructed slices, there were significant differences between overlap of 0% and of 50% in all levels of scanning parameters, and between overlap of 25% and of 50% in overall accuracy and overall mean score. Among the 18 scanning sequences, the highest score (4.94) was achieved with 1.25 mm detector-row collimation, 3.0 pitch, and 50% overlap between reconstructed slices. CONCLUSION: Comparison of the quality of reconstructed 3D images obtained using multidetector-row helical CT and various scanning techniques indicated that the 1.25 mm, 3.0, 50% scanning sequence was best. Quality improved as detector-row collimation decreased; as pitch was reduced from 6.0 to 3.0; and as overlap between reconstructed slices increased. |
format | Text |
id | pubmed-2713987 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2002 |
publisher | The Korean Radiological Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-27139872009-07-23 The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters Shin, Ji Hoon Lee, Ho Kyu Choi, Choong Gon Suh, Dae Chul Lim, Tae-Hwan Kang, Weechang Korean J Radiol Original Article OBJECTIVE: To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. MATERIALS AND METHODS: Four objects with different surfaces and contours were scanned using multidetector-row helical CT at three detector-row collimations (1.25, 2.50, 5.00 mm), two pitches (3.0, 6.0), and three different degrees of overlap between the reconstructed slices (0%, 25%, 50%). Reconstructed 3D images of the resulting 72 sets of data were produced using volumetric rendering. The 72 images were graded on a scale from 1 (worst) to 5 (best) for each of four rating criteria, giving a mean score for each criterion and an overall mean score. Statistical analysis was used to assess differences in image quality according to scanning parameter levels. RESULTS: The mean score for each rating criterion, and the overall mean score, varied significantly according to the scanning parameter levels used. With regard to detector-row collimation and pitch, all levels of scanning parameters gave rise to significant differences, while in the degree of overlap of reconstructed slices, there were significant differences between overlap of 0% and of 50% in all levels of scanning parameters, and between overlap of 25% and of 50% in overall accuracy and overall mean score. Among the 18 scanning sequences, the highest score (4.94) was achieved with 1.25 mm detector-row collimation, 3.0 pitch, and 50% overlap between reconstructed slices. CONCLUSION: Comparison of the quality of reconstructed 3D images obtained using multidetector-row helical CT and various scanning techniques indicated that the 1.25 mm, 3.0, 50% scanning sequence was best. Quality improved as detector-row collimation decreased; as pitch was reduced from 6.0 to 3.0; and as overlap between reconstructed slices increased. The Korean Radiological Society 2002 2002-03-31 /pmc/articles/PMC2713987/ /pubmed/11919479 http://dx.doi.org/10.3348/kjr.2002.3.1.49 Text en Copyright © 2002 The Korean Radiological Society http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Shin, Ji Hoon Lee, Ho Kyu Choi, Choong Gon Suh, Dae Chul Lim, Tae-Hwan Kang, Weechang The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters |
title | The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters |
title_full | The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters |
title_fullStr | The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters |
title_full_unstemmed | The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters |
title_short | The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters |
title_sort | quality of reconstructed 3d images in multidetector-row helical ct: experimental study involving scan parameters |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2713987/ https://www.ncbi.nlm.nih.gov/pubmed/11919479 http://dx.doi.org/10.3348/kjr.2002.3.1.49 |
work_keys_str_mv | AT shinjihoon thequalityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT leehokyu thequalityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT choichoonggon thequalityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT suhdaechul thequalityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT limtaehwan thequalityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT kangweechang thequalityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT shinjihoon qualityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT leehokyu qualityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT choichoonggon qualityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT suhdaechul qualityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT limtaehwan qualityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters AT kangweechang qualityofreconstructed3dimagesinmultidetectorrowhelicalctexperimentalstudyinvolvingscanparameters |