Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?
BACKGROUND: Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the...
Autores principales: | , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2715374/ https://www.ncbi.nlm.nih.gov/pubmed/19545452 http://dx.doi.org/10.1186/1476-7120-7-29 |
_version_ | 1782169766759235584 |
---|---|
author | Manouras, Aristomenis Shala, Arben Nyktari, Evangelia Shahgaldi, Kambiz Winter, Reidar Vardas, Panagiotis Brodin, Lars-Åke Nowak, Jacek |
author_facet | Manouras, Aristomenis Shala, Arben Nyktari, Evangelia Shahgaldi, Kambiz Winter, Reidar Vardas, Panagiotis Brodin, Lars-Åke Nowak, Jacek |
author_sort | Manouras, Aristomenis |
collection | PubMed |
description | BACKGROUND: Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and different spectral TD procedures was evaluated. METHODS: Left ventricular (LV) longitudinal systolic myocardial velocities and displacement during ejection period were quantified at the basal septal and lateral wall in 24 healthy individuals (4 women and 20 men, 34 ± 12 years) using spectral TD, colour TD and M-mode recordings. Mean, maximal and minimal spectral TD systolic velocities and the corresponding displacement values were obtained by measurements at the outer and inner borders of the spectral velocity signal. The results were then compared with those obtained with the two other modalities used. RESULTS: Systolic myocardial velocities derived from mean spectral TD frequencies were highly concordant with corresponding colour TD measurements (mean difference 0.10 ± 0.54 cm/sec in septal and 0.09 ± 0.97 cm/sec in lateral wall). Similarly, the agreement between spectral and colour TD (mean difference 0.22 ± 0.74 mm in septal and 0.02 ± 0.86 mm in lateral wall) as well as M-mode was good when mean spectral velocities were temporally integrated and the results did not differ statistically. Conversely, displacement values from the inner or outer border of the spectral signal differed significantly from values obtained with colour TD and M-mode (p < 0.001, in both cases). CONCLUSION: LV systolic myocardial measurements based on mean spectral TD frequencies are highly concordant with those provided by colour TD and M-mode. Hence, in order to maintain compatibility of the results, the use of this particular spectral TD procedure should be advocated in clinical praxis. |
format | Text |
id | pubmed-2715374 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-27153742009-07-25 Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible? Manouras, Aristomenis Shala, Arben Nyktari, Evangelia Shahgaldi, Kambiz Winter, Reidar Vardas, Panagiotis Brodin, Lars-Åke Nowak, Jacek Cardiovasc Ultrasound Research BACKGROUND: Tissue Doppler (TD) in pulsed mode (spectral TD) and colour TD are the two modalities today available in tissue velocity echocardiography (TVE). Previous studies have shown poor agreement between these two methods when measuring myocardial velocities and displacement. In this study, the concordance between the myocardial velocity and displacement measurements using colour TD and different spectral TD procedures was evaluated. METHODS: Left ventricular (LV) longitudinal systolic myocardial velocities and displacement during ejection period were quantified at the basal septal and lateral wall in 24 healthy individuals (4 women and 20 men, 34 ± 12 years) using spectral TD, colour TD and M-mode recordings. Mean, maximal and minimal spectral TD systolic velocities and the corresponding displacement values were obtained by measurements at the outer and inner borders of the spectral velocity signal. The results were then compared with those obtained with the two other modalities used. RESULTS: Systolic myocardial velocities derived from mean spectral TD frequencies were highly concordant with corresponding colour TD measurements (mean difference 0.10 ± 0.54 cm/sec in septal and 0.09 ± 0.97 cm/sec in lateral wall). Similarly, the agreement between spectral and colour TD (mean difference 0.22 ± 0.74 mm in septal and 0.02 ± 0.86 mm in lateral wall) as well as M-mode was good when mean spectral velocities were temporally integrated and the results did not differ statistically. Conversely, displacement values from the inner or outer border of the spectral signal differed significantly from values obtained with colour TD and M-mode (p < 0.001, in both cases). CONCLUSION: LV systolic myocardial measurements based on mean spectral TD frequencies are highly concordant with those provided by colour TD and M-mode. Hence, in order to maintain compatibility of the results, the use of this particular spectral TD procedure should be advocated in clinical praxis. BioMed Central 2009-06-23 /pmc/articles/PMC2715374/ /pubmed/19545452 http://dx.doi.org/10.1186/1476-7120-7-29 Text en Copyright © 2009 Manouras et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Manouras, Aristomenis Shala, Arben Nyktari, Evangelia Shahgaldi, Kambiz Winter, Reidar Vardas, Panagiotis Brodin, Lars-Åke Nowak, Jacek Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible? |
title | Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible? |
title_full | Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible? |
title_fullStr | Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible? |
title_full_unstemmed | Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible? |
title_short | Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible? |
title_sort | are measurements of systolic myocardial velocities and displacement with colour and spectral tissue doppler compatible? |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2715374/ https://www.ncbi.nlm.nih.gov/pubmed/19545452 http://dx.doi.org/10.1186/1476-7120-7-29 |
work_keys_str_mv | AT manourasaristomenis aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible AT shalaarben aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible AT nyktarievangelia aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible AT shahgaldikambiz aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible AT winterreidar aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible AT vardaspanagiotis aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible AT brodinlarsake aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible AT nowakjacek aremeasurementsofsystolicmyocardialvelocitiesanddisplacementwithcolourandspectraltissuedopplercompatible |