Cargando…
Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system
BACKGROUND: The rapid, simple determination of surfactants in environmental samples is essential because of the extensive use and its potential as contaminants. We describe a simple, rapid chemiluminescence method for the direct determination of the non-ionic surfactant Triton X-100 (polyethylene gl...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2715391/ https://www.ncbi.nlm.nih.gov/pubmed/19570217 http://dx.doi.org/10.1186/1752-153X-3-7 |
_version_ | 1782169770846584832 |
---|---|
author | Liu, Xiaoyu Li, Aifang Zhou, Baohui Qiu, Chaokun Ren, Hongmin |
author_facet | Liu, Xiaoyu Li, Aifang Zhou, Baohui Qiu, Chaokun Ren, Hongmin |
author_sort | Liu, Xiaoyu |
collection | PubMed |
description | BACKGROUND: The rapid, simple determination of surfactants in environmental samples is essential because of the extensive use and its potential as contaminants. We describe a simple, rapid chemiluminescence method for the direct determination of the non-ionic surfactant Triton X-100 (polyethylene glycol tert-octylphenyl ether) in environmental water samples. The optimized experimental conditions were selected, and the mechanism of the Luminol-H(2)O(2)-Triton X-100 chemiluminesence system was also studied. RESULTS: The novel chemiluminescence method for the determination of non-ionic surfactant Triton X-100 was based on the phenomenon that Triton X-100 greatly enhanced the CL signal of the luminol-H(2)O(2 )system. The alkaline medium of luminol and the pH value obviously affected the results. Luminol concentration and hydrogen peroxide concentration also affected the results. The optimal conditions were: Na(2)CO(3 )being the medium, pH value 12.5, luminol concentration 1.0 × 10(-4 )mol L(-1), H(2)O(2 )concentration 0.4 mol L(-1). The possible mechanism was studied and proposed. CONCLUSION: Under the optimal conditions, the standard curve was drawn up and quotas were evaluated. The linear range was 2 × 10(-4 )g·mL(-1)-4 × 10(-2 )g·mL(-1 )(w/v), and the detection limit was 3.97 × 10(-5 )g·mL(-1 )Triton X-100 (w/v). The relative standard deviation was less than 4.73% for 2 × 10(-2 )g·mL(-1 )(w/v) Triton X-100 (n = 7). This method has been applied to the determination of Triton X-100 in environmental water samples. The desirable recovery ratio was between 96%–102% and the relative standard deviation was 2.5%–3.3%. The luminescence mechanism was also discussed in detail based on the fluorescence spectrum and the kinetic curve, and demonstrated that Triton X-100-luminol-H(2)O(2 )was a rapid reaction. |
format | Text |
id | pubmed-2715391 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-27153912009-07-25 Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system Liu, Xiaoyu Li, Aifang Zhou, Baohui Qiu, Chaokun Ren, Hongmin Chem Cent J Research Article BACKGROUND: The rapid, simple determination of surfactants in environmental samples is essential because of the extensive use and its potential as contaminants. We describe a simple, rapid chemiluminescence method for the direct determination of the non-ionic surfactant Triton X-100 (polyethylene glycol tert-octylphenyl ether) in environmental water samples. The optimized experimental conditions were selected, and the mechanism of the Luminol-H(2)O(2)-Triton X-100 chemiluminesence system was also studied. RESULTS: The novel chemiluminescence method for the determination of non-ionic surfactant Triton X-100 was based on the phenomenon that Triton X-100 greatly enhanced the CL signal of the luminol-H(2)O(2 )system. The alkaline medium of luminol and the pH value obviously affected the results. Luminol concentration and hydrogen peroxide concentration also affected the results. The optimal conditions were: Na(2)CO(3 )being the medium, pH value 12.5, luminol concentration 1.0 × 10(-4 )mol L(-1), H(2)O(2 )concentration 0.4 mol L(-1). The possible mechanism was studied and proposed. CONCLUSION: Under the optimal conditions, the standard curve was drawn up and quotas were evaluated. The linear range was 2 × 10(-4 )g·mL(-1)-4 × 10(-2 )g·mL(-1 )(w/v), and the detection limit was 3.97 × 10(-5 )g·mL(-1 )Triton X-100 (w/v). The relative standard deviation was less than 4.73% for 2 × 10(-2 )g·mL(-1 )(w/v) Triton X-100 (n = 7). This method has been applied to the determination of Triton X-100 in environmental water samples. The desirable recovery ratio was between 96%–102% and the relative standard deviation was 2.5%–3.3%. The luminescence mechanism was also discussed in detail based on the fluorescence spectrum and the kinetic curve, and demonstrated that Triton X-100-luminol-H(2)O(2 )was a rapid reaction. BioMed Central 2009-07-01 /pmc/articles/PMC2715391/ /pubmed/19570217 http://dx.doi.org/10.1186/1752-153X-3-7 Text en Copyright © 2009 Liu et al |
spellingShingle | Research Article Liu, Xiaoyu Li, Aifang Zhou, Baohui Qiu, Chaokun Ren, Hongmin Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system |
title | Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system |
title_full | Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system |
title_fullStr | Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system |
title_full_unstemmed | Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system |
title_short | Chemiluminescence determination of surfactant Triton X-100 in environmental water with luminol-hydrogen peroxide system |
title_sort | chemiluminescence determination of surfactant triton x-100 in environmental water with luminol-hydrogen peroxide system |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2715391/ https://www.ncbi.nlm.nih.gov/pubmed/19570217 http://dx.doi.org/10.1186/1752-153X-3-7 |
work_keys_str_mv | AT liuxiaoyu chemiluminescencedeterminationofsurfactanttritonx100inenvironmentalwaterwithluminolhydrogenperoxidesystem AT liaifang chemiluminescencedeterminationofsurfactanttritonx100inenvironmentalwaterwithluminolhydrogenperoxidesystem AT zhoubaohui chemiluminescencedeterminationofsurfactanttritonx100inenvironmentalwaterwithluminolhydrogenperoxidesystem AT qiuchaokun chemiluminescencedeterminationofsurfactanttritonx100inenvironmentalwaterwithluminolhydrogenperoxidesystem AT renhongmin chemiluminescencedeterminationofsurfactanttritonx100inenvironmentalwaterwithluminolhydrogenperoxidesystem |