Cargando…
Determination of the Labile Iron Pool of Human Lymphocytes using the Fluorescent Probe, CP655
The present study introduces a method for determining the labile iron pool (LIP) in human lymphocytes. It is measured using the probe CP655, the fluorescence of which is stoichiometrically quenched by the addition of iron. The intracellular CP655 fluorescence in lymphocytes was quenched by increasin...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Libertas Academica
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2716813/ https://www.ncbi.nlm.nih.gov/pubmed/19662178 |
_version_ | 1782169844728201216 |
---|---|
author | Ma, Yongmin Liu, Zudong Hider, Robert C Petrat, Frank |
author_facet | Ma, Yongmin Liu, Zudong Hider, Robert C Petrat, Frank |
author_sort | Ma, Yongmin |
collection | PubMed |
description | The present study introduces a method for determining the labile iron pool (LIP) in human lymphocytes. It is measured using the probe CP655, the fluorescence of which is stoichiometrically quenched by the addition of iron. The intracellular CP655 fluorescence in lymphocytes was quenched by increasing intracellular iron concentrations using the highly lipophilic 8-hydroxyquinoline iron complex. Intracellular fluorescence quenching, mediated by the physiological intracellular labile iron, can be recovered on the addition of excess membrane-permeable iron chelator, CP94. The intracellular probe concentration was measured using laser scanning microscopy. An ex situ calibration was performed in a “cytosolic” medium based on the determined intracellular CP655 concentration and probe fluorescence quenching in the presence of iron. The concentration of the LIP of healthy human lymphocytes was determined to be 0.57 ± 0.27 μM. The use of the fluorescent probe CP655 renders it possible to record the time course of iron uptake and iron chelation by CP94 in single intact lymphocytes. |
format | Text |
id | pubmed-2716813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | Libertas Academica |
record_format | MEDLINE/PubMed |
spelling | pubmed-27168132009-08-06 Determination of the Labile Iron Pool of Human Lymphocytes using the Fluorescent Probe, CP655 Ma, Yongmin Liu, Zudong Hider, Robert C Petrat, Frank Anal Chem Insights Original Research The present study introduces a method for determining the labile iron pool (LIP) in human lymphocytes. It is measured using the probe CP655, the fluorescence of which is stoichiometrically quenched by the addition of iron. The intracellular CP655 fluorescence in lymphocytes was quenched by increasing intracellular iron concentrations using the highly lipophilic 8-hydroxyquinoline iron complex. Intracellular fluorescence quenching, mediated by the physiological intracellular labile iron, can be recovered on the addition of excess membrane-permeable iron chelator, CP94. The intracellular probe concentration was measured using laser scanning microscopy. An ex situ calibration was performed in a “cytosolic” medium based on the determined intracellular CP655 concentration and probe fluorescence quenching in the presence of iron. The concentration of the LIP of healthy human lymphocytes was determined to be 0.57 ± 0.27 μM. The use of the fluorescent probe CP655 renders it possible to record the time course of iron uptake and iron chelation by CP94 in single intact lymphocytes. Libertas Academica 2007-09-17 /pmc/articles/PMC2716813/ /pubmed/19662178 Text en Copyright © 2007 The authors. http://creativecommons.org/licenses/by/3.0 This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Original Research Ma, Yongmin Liu, Zudong Hider, Robert C Petrat, Frank Determination of the Labile Iron Pool of Human Lymphocytes using the Fluorescent Probe, CP655 |
title | Determination of the Labile Iron Pool of Human Lymphocytes using the Fluorescent Probe, CP655 |
title_full | Determination of the Labile Iron Pool of Human Lymphocytes using the Fluorescent Probe, CP655 |
title_fullStr | Determination of the Labile Iron Pool of Human Lymphocytes using the Fluorescent Probe, CP655 |
title_full_unstemmed | Determination of the Labile Iron Pool of Human Lymphocytes using the Fluorescent Probe, CP655 |
title_short | Determination of the Labile Iron Pool of Human Lymphocytes using the Fluorescent Probe, CP655 |
title_sort | determination of the labile iron pool of human lymphocytes using the fluorescent probe, cp655 |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2716813/ https://www.ncbi.nlm.nih.gov/pubmed/19662178 |
work_keys_str_mv | AT mayongmin determinationofthelabileironpoolofhumanlymphocytesusingthefluorescentprobecp655 AT liuzudong determinationofthelabileironpoolofhumanlymphocytesusingthefluorescentprobecp655 AT hiderrobertc determinationofthelabileironpoolofhumanlymphocytesusingthefluorescentprobecp655 AT petratfrank determinationofthelabileironpoolofhumanlymphocytesusingthefluorescentprobecp655 |