High flow biphasic positive airway pressure by helmet – effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure

INTRODUCTION: Non-invasive ventilation (NIV) with a helmet device is often associated with poor patient-ventilator synchrony and impaired carbon dioxide (CO(2)) removal, which might lead to failure. A possible solution is to use a high free flow system in combination with a time-cycled pressure valv...

Descripción completa

Detalles Bibliográficos
Autores principales: Moerer, Onnen, Herrmann, Peter, Hinz, José, Severgnini, Paolo, Calderini, Edoardo, Quintel, Michael, Pelosi, Paolo
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2717454/
https://www.ncbi.nlm.nih.gov/pubmed/19500369
http://dx.doi.org/10.1186/cc7907
_version_ 1782169902348500992
author Moerer, Onnen
Herrmann, Peter
Hinz, José
Severgnini, Paolo
Calderini, Edoardo
Quintel, Michael
Pelosi, Paolo
author_facet Moerer, Onnen
Herrmann, Peter
Hinz, José
Severgnini, Paolo
Calderini, Edoardo
Quintel, Michael
Pelosi, Paolo
author_sort Moerer, Onnen
collection PubMed
description INTRODUCTION: Non-invasive ventilation (NIV) with a helmet device is often associated with poor patient-ventilator synchrony and impaired carbon dioxide (CO(2)) removal, which might lead to failure. A possible solution is to use a high free flow system in combination with a time-cycled pressure valve placed into the expiratory circuit (HF-BiPAP). This system would be independent from triggering while providing a high flow to eliminate CO(2). METHODS: Conventional pressure support ventilation (PSV) and time-cycled biphasic pressure controlled ventilation (BiVent) delivered by an Intensive Care Unit ventilator were compared to HF-BiPAP in an in vitro lung model study. Variables included delta pressures of 5 and 15 cmH2O, respiratory rates of 15 and 30 breaths/min, inspiratory efforts (respiratory drive) of 2.5 and 10 cmH2O) and different lung characteristics. Additionally, CO(2 )removal and noise exposure were measured. RESULTS: Pressurization during inspiration was more effective with pressure controlled modes compared to PSV (P < 0.001) at similar tidal volumes. During the expiratory phase, BiVent and HF-BiPAP led to an increase in pressure burden compared to PSV. This was especially true at higher upper pressures (P < 0.001). At high level of asynchrony both HF-BiPAP and BiVent were less effective. Only HF-BiPAP ventilation effectively removed CO2 (P < 0.001) during all settings. Noise exposure was higher during HF-BiPAP (P < 0.001). CONCLUSIONS: This study demonstrates that in a lung model, the efficiency of NIV by helmet can be improved by using HF-BiPAP. However, it imposes a higher pressure during the expiratory phase. CO2 was almost completely removed with HF-BiPAP during all settings.
format Text
id pubmed-2717454
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-27174542009-07-29 High flow biphasic positive airway pressure by helmet – effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure Moerer, Onnen Herrmann, Peter Hinz, José Severgnini, Paolo Calderini, Edoardo Quintel, Michael Pelosi, Paolo Crit Care Research INTRODUCTION: Non-invasive ventilation (NIV) with a helmet device is often associated with poor patient-ventilator synchrony and impaired carbon dioxide (CO(2)) removal, which might lead to failure. A possible solution is to use a high free flow system in combination with a time-cycled pressure valve placed into the expiratory circuit (HF-BiPAP). This system would be independent from triggering while providing a high flow to eliminate CO(2). METHODS: Conventional pressure support ventilation (PSV) and time-cycled biphasic pressure controlled ventilation (BiVent) delivered by an Intensive Care Unit ventilator were compared to HF-BiPAP in an in vitro lung model study. Variables included delta pressures of 5 and 15 cmH2O, respiratory rates of 15 and 30 breaths/min, inspiratory efforts (respiratory drive) of 2.5 and 10 cmH2O) and different lung characteristics. Additionally, CO(2 )removal and noise exposure were measured. RESULTS: Pressurization during inspiration was more effective with pressure controlled modes compared to PSV (P < 0.001) at similar tidal volumes. During the expiratory phase, BiVent and HF-BiPAP led to an increase in pressure burden compared to PSV. This was especially true at higher upper pressures (P < 0.001). At high level of asynchrony both HF-BiPAP and BiVent were less effective. Only HF-BiPAP ventilation effectively removed CO2 (P < 0.001) during all settings. Noise exposure was higher during HF-BiPAP (P < 0.001). CONCLUSIONS: This study demonstrates that in a lung model, the efficiency of NIV by helmet can be improved by using HF-BiPAP. However, it imposes a higher pressure during the expiratory phase. CO2 was almost completely removed with HF-BiPAP during all settings. BioMed Central 2009 2009-06-05 /pmc/articles/PMC2717454/ /pubmed/19500369 http://dx.doi.org/10.1186/cc7907 Text en Copyright © 2009 Moerer et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Moerer, Onnen
Herrmann, Peter
Hinz, José
Severgnini, Paolo
Calderini, Edoardo
Quintel, Michael
Pelosi, Paolo
High flow biphasic positive airway pressure by helmet – effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure
title High flow biphasic positive airway pressure by helmet – effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure
title_full High flow biphasic positive airway pressure by helmet – effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure
title_fullStr High flow biphasic positive airway pressure by helmet – effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure
title_full_unstemmed High flow biphasic positive airway pressure by helmet – effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure
title_short High flow biphasic positive airway pressure by helmet – effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure
title_sort high flow biphasic positive airway pressure by helmet – effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2717454/
https://www.ncbi.nlm.nih.gov/pubmed/19500369
http://dx.doi.org/10.1186/cc7907
work_keys_str_mv AT moereronnen highflowbiphasicpositiveairwaypressurebyhelmeteffectsonpressurizationtidalvolumecarbondioxideaccumulationandnoiseexposure
AT herrmannpeter highflowbiphasicpositiveairwaypressurebyhelmeteffectsonpressurizationtidalvolumecarbondioxideaccumulationandnoiseexposure
AT hinzjose highflowbiphasicpositiveairwaypressurebyhelmeteffectsonpressurizationtidalvolumecarbondioxideaccumulationandnoiseexposure
AT severgninipaolo highflowbiphasicpositiveairwaypressurebyhelmeteffectsonpressurizationtidalvolumecarbondioxideaccumulationandnoiseexposure
AT calderiniedoardo highflowbiphasicpositiveairwaypressurebyhelmeteffectsonpressurizationtidalvolumecarbondioxideaccumulationandnoiseexposure
AT quintelmichael highflowbiphasicpositiveairwaypressurebyhelmeteffectsonpressurizationtidalvolumecarbondioxideaccumulationandnoiseexposure
AT pelosipaolo highflowbiphasicpositiveairwaypressurebyhelmeteffectsonpressurizationtidalvolumecarbondioxideaccumulationandnoiseexposure