Cargando…

Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study

BACKGROUND: Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occur...

Descripción completa

Detalles Bibliográficos
Autores principales: Nederkoorn, Paul J, Brown, Martin M
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2722571/
https://www.ncbi.nlm.nih.gov/pubmed/19624830
http://dx.doi.org/10.1186/1471-2377-9-36
_version_ 1782170312682504192
author Nederkoorn, Paul J
Brown, Martin M
author_facet Nederkoorn, Paul J
Brown, Martin M
author_sort Nederkoorn, Paul J
collection PubMed
description BACKGROUND: Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occurrence of in-stent restenosis. An un-stented carotid artery is likely to have a more elastic vessel wall than a stented one, even if stenosis is present. Therefore, duplex ultrasound cut-off criteria for the degrees of an in-stent stenosis, based on blood velocity parameters, are probably different from the established cut-offs used for un-stented arteries. Routine criteria can not be applied to stented arteries but new criteria need to be established for this particular purpose. METHODS/DESIGN: Current literature was systematically reviewed. From the selected studies, the following data were extracted: publication year, population size, whether the study was prospective, duplex ultrasound cut-off criteria reported, which reference test was used, and if there was an indication for selection bias and for verification bias in particular. Previous studies often were retrospective, or the reference test (DSA or CTA) was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. RESULTS: In general, the velocity cut-off values for stenosis measurements in stented arteries were higher than those reported for unstented arteries. Previous studies often were retrospective, or the reference test (DSA or CTA) was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. DISCUSSION: To address the deficiencies of the existing studies, we propose a prospective cohort study nested within the International Carotid Stenting Study (ICSS), an international multi-centre trial in which over 1,700 patients have been randomised between stenting and CEA. In this cohort we will enrol a minimum of 300 patients treated with a stent. All patients undergo regular DUS examination at the yearly follow-up visit according to the ICSS protocol. To avoid verification bias, an additional computed tomography angiography (CTA) will be performed as a reference test in all consecutive patients, regardless of the degree of stenosis on the initial DUS test.
format Text
id pubmed-2722571
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-27225712009-08-07 Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study Nederkoorn, Paul J Brown, Martin M BMC Neurol Study Protocol BACKGROUND: Carotid angioplasty with stenting is a relatively new, increasingly used, less-invasive treatment for the treatment of symptomatic carotid artery stenosis. It is being evaluated in ongoing and nearly finished randomized trials. An important factor in the evaluation of stents is the occurrence of in-stent restenosis. An un-stented carotid artery is likely to have a more elastic vessel wall than a stented one, even if stenosis is present. Therefore, duplex ultrasound cut-off criteria for the degrees of an in-stent stenosis, based on blood velocity parameters, are probably different from the established cut-offs used for un-stented arteries. Routine criteria can not be applied to stented arteries but new criteria need to be established for this particular purpose. METHODS/DESIGN: Current literature was systematically reviewed. From the selected studies, the following data were extracted: publication year, population size, whether the study was prospective, duplex ultrasound cut-off criteria reported, which reference test was used, and if there was an indication for selection bias and for verification bias in particular. Previous studies often were retrospective, or the reference test (DSA or CTA) was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. RESULTS: In general, the velocity cut-off values for stenosis measurements in stented arteries were higher than those reported for unstented arteries. Previous studies often were retrospective, or the reference test (DSA or CTA) was carried out only when a patient was suspected of having restenosis at DUS, which may result in verification bias. DISCUSSION: To address the deficiencies of the existing studies, we propose a prospective cohort study nested within the International Carotid Stenting Study (ICSS), an international multi-centre trial in which over 1,700 patients have been randomised between stenting and CEA. In this cohort we will enrol a minimum of 300 patients treated with a stent. All patients undergo regular DUS examination at the yearly follow-up visit according to the ICSS protocol. To avoid verification bias, an additional computed tomography angiography (CTA) will be performed as a reference test in all consecutive patients, regardless of the degree of stenosis on the initial DUS test. BioMed Central 2009-07-22 /pmc/articles/PMC2722571/ /pubmed/19624830 http://dx.doi.org/10.1186/1471-2377-9-36 Text en Copyright © 2009 Nederkoorn and Brown; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Study Protocol
Nederkoorn, Paul J
Brown, Martin M
Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study
title Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study
title_full Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study
title_fullStr Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study
title_full_unstemmed Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study
title_short Optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: Review and protocol for a diagnostic study
title_sort optimal cut-off criteria for duplex ultrasound for the diagnosis of restenosis in stented carotid arteries: review and protocol for a diagnostic study
topic Study Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2722571/
https://www.ncbi.nlm.nih.gov/pubmed/19624830
http://dx.doi.org/10.1186/1471-2377-9-36
work_keys_str_mv AT nederkoornpaulj optimalcutoffcriteriaforduplexultrasoundforthediagnosisofrestenosisinstentedcarotidarteriesreviewandprotocolforadiagnosticstudy
AT brownmartinm optimalcutoffcriteriaforduplexultrasoundforthediagnosisofrestenosisinstentedcarotidarteriesreviewandprotocolforadiagnosticstudy