Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography

PURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable angles and 32 normal open-angle eyes were included. Anterior chamber ang...

Descripción completa

Detalles Bibliográficos
Autores principales: Hong, Samin, Yi, Jeong-Ho, Kang, Sung Yong, Seong, Gong Je, Kim, Chan Yun
Formato: Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2730615/
https://www.ncbi.nlm.nih.gov/pubmed/19718401
http://dx.doi.org/10.3349/ymj.2009.50.4.525
_version_ 1782170911491751936
author Hong, Samin
Yi, Jeong-Ho
Kang, Sung Yong
Seong, Gong Je
Kim, Chan Yun
author_facet Hong, Samin
Yi, Jeong-Ho
Kang, Sung Yong
Seong, Gong Je
Kim, Chan Yun
author_sort Hong, Samin
collection PubMed
description PURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable angles and 32 normal open-angle eyes were included. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Receiver operating characteristic (ROC) curve was constructed for each parameter and the area under the ROC curve (AUC) was calculated. RESULTS: Values of ACA and ACD measured by PTC and AOCT were similar not only in normal open angle eyes but also in occludable angle eyes. For detection of occludable angle, the AUCs of PTC with ACA and ACD were 0.935 and 0.969, respectively. The AUCs of AOCT with ACA and ACD were 0.904 and 0.947, respectively. CONCLUSION: Both PTC and AOCT allow accurate discrimination between open and occludable angle eyes, so that they may aid to screening the occludable angles.
format Text
id pubmed-2730615
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-27306152009-08-31 Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography Hong, Samin Yi, Jeong-Ho Kang, Sung Yong Seong, Gong Je Kim, Chan Yun Yonsei Med J Original Article PURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable angles and 32 normal open-angle eyes were included. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Receiver operating characteristic (ROC) curve was constructed for each parameter and the area under the ROC curve (AUC) was calculated. RESULTS: Values of ACA and ACD measured by PTC and AOCT were similar not only in normal open angle eyes but also in occludable angle eyes. For detection of occludable angle, the AUCs of PTC with ACA and ACD were 0.935 and 0.969, respectively. The AUCs of AOCT with ACA and ACD were 0.904 and 0.947, respectively. CONCLUSION: Both PTC and AOCT allow accurate discrimination between open and occludable angle eyes, so that they may aid to screening the occludable angles. Yonsei University College of Medicine 2009-08-31 2009-08-19 /pmc/articles/PMC2730615/ /pubmed/19718401 http://dx.doi.org/10.3349/ymj.2009.50.4.525 Text en © Copyright: Yonsei University College of Medicine 2009 http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hong, Samin
Yi, Jeong-Ho
Kang, Sung Yong
Seong, Gong Je
Kim, Chan Yun
Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography
title Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography
title_full Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography
title_fullStr Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography
title_full_unstemmed Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography
title_short Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography
title_sort detection of occludable angles with the pentacam and the anterior segment optical coherence tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2730615/
https://www.ncbi.nlm.nih.gov/pubmed/19718401
http://dx.doi.org/10.3349/ymj.2009.50.4.525
work_keys_str_mv AT hongsamin detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography
AT yijeongho detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography
AT kangsungyong detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography
AT seonggongje detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography
AT kimchanyun detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography