PURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable angles and 32 normal open-angle eyes were included. Anterior chamber ang...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2730615/ https://www.ncbi.nlm.nih.gov/pubmed/19718401 http://dx.doi.org/10.3349/ymj.2009.50.4.525 |
_version_ | 1782170911491751936 |
---|---|
author | Hong, Samin Yi, Jeong-Ho Kang, Sung Yong Seong, Gong Je Kim, Chan Yun |
author_facet | Hong, Samin Yi, Jeong-Ho Kang, Sung Yong Seong, Gong Je Kim, Chan Yun |
author_sort | Hong, Samin |
collection | PubMed |
description | PURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable angles and 32 normal open-angle eyes were included. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Receiver operating characteristic (ROC) curve was constructed for each parameter and the area under the ROC curve (AUC) was calculated. RESULTS: Values of ACA and ACD measured by PTC and AOCT were similar not only in normal open angle eyes but also in occludable angle eyes. For detection of occludable angle, the AUCs of PTC with ACA and ACD were 0.935 and 0.969, respectively. The AUCs of AOCT with ACA and ACD were 0.904 and 0.947, respectively. CONCLUSION: Both PTC and AOCT allow accurate discrimination between open and occludable angle eyes, so that they may aid to screening the occludable angles. |
format | Text |
id | pubmed-2730615 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-27306152009-08-31 Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography Hong, Samin Yi, Jeong-Ho Kang, Sung Yong Seong, Gong Je Kim, Chan Yun Yonsei Med J Original Article PURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable angles and 32 normal open-angle eyes were included. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Receiver operating characteristic (ROC) curve was constructed for each parameter and the area under the ROC curve (AUC) was calculated. RESULTS: Values of ACA and ACD measured by PTC and AOCT were similar not only in normal open angle eyes but also in occludable angle eyes. For detection of occludable angle, the AUCs of PTC with ACA and ACD were 0.935 and 0.969, respectively. The AUCs of AOCT with ACA and ACD were 0.904 and 0.947, respectively. CONCLUSION: Both PTC and AOCT allow accurate discrimination between open and occludable angle eyes, so that they may aid to screening the occludable angles. Yonsei University College of Medicine 2009-08-31 2009-08-19 /pmc/articles/PMC2730615/ /pubmed/19718401 http://dx.doi.org/10.3349/ymj.2009.50.4.525 Text en © Copyright: Yonsei University College of Medicine 2009 http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Hong, Samin Yi, Jeong-Ho Kang, Sung Yong Seong, Gong Je Kim, Chan Yun Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography |
title | Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography |
title_full | Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography |
title_fullStr | Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography |
title_full_unstemmed | Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography |
title_short | Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography |
title_sort | detection of occludable angles with the pentacam and the anterior segment optical coherence tomography |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2730615/ https://www.ncbi.nlm.nih.gov/pubmed/19718401 http://dx.doi.org/10.3349/ymj.2009.50.4.525 |
work_keys_str_mv | AT hongsamin detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography AT yijeongho detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography AT kangsungyong detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography AT seonggongje detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography AT kimchanyun detectionofoccludableangleswiththepentacamandtheanteriorsegmentopticalcoherencetomography |