Cargando…

Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

PURPOSE: The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthrosco...

Descripción completa

Detalles Bibliográficos
Autores principales: Schreinemachers, Saskia A., van der Hulst, Victor P. M., Willems, W. Jaap, Bipat, Shandra, van der Woude, Henk-Jan
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2733185/
https://www.ncbi.nlm.nih.gov/pubmed/19294377
http://dx.doi.org/10.1007/s00256-009-0680-3
_version_ 1782171097794347008
author Schreinemachers, Saskia A.
van der Hulst, Victor P. M.
Willems, W. Jaap
Bipat, Shandra
van der Woude, Henk-Jan
author_facet Schreinemachers, Saskia A.
van der Hulst, Victor P. M.
Willems, W. Jaap
Bipat, Shandra
van der Woude, Henk-Jan
author_sort Schreinemachers, Saskia A.
collection PubMed
description PURPOSE: The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. MATERIALS AND METHODS: Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. RESULTS: Weighted kappa values of ABER and conventional MR arthrography were 0.48–0.65 and 0.60–0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48–61% and 52–70%, respectively) and specificity (80–94% and 91–95%). CONCLUSION: Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears.
format Text
id pubmed-2733185
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-27331852009-08-28 Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography? Schreinemachers, Saskia A. van der Hulst, Victor P. M. Willems, W. Jaap Bipat, Shandra van der Woude, Henk-Jan Skeletal Radiol Scientific Article PURPOSE: The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. MATERIALS AND METHODS: Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. RESULTS: Weighted kappa values of ABER and conventional MR arthrography were 0.48–0.65 and 0.60–0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48–61% and 52–70%, respectively) and specificity (80–94% and 91–95%). CONCLUSION: Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. Springer-Verlag 2009-03-18 2009-10 /pmc/articles/PMC2733185/ /pubmed/19294377 http://dx.doi.org/10.1007/s00256-009-0680-3 Text en © The Author(s) 2009
spellingShingle Scientific Article
Schreinemachers, Saskia A.
van der Hulst, Victor P. M.
Willems, W. Jaap
Bipat, Shandra
van der Woude, Henk-Jan
Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?
title Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?
title_full Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?
title_fullStr Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?
title_full_unstemmed Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?
title_short Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?
title_sort detection of partial-thickness supraspinatus tendon tears: is a single direct mr arthrography series in aber position as accurate as conventional mr arthrography?
topic Scientific Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2733185/
https://www.ncbi.nlm.nih.gov/pubmed/19294377
http://dx.doi.org/10.1007/s00256-009-0680-3
work_keys_str_mv AT schreinemacherssaskiaa detectionofpartialthicknesssupraspinatustendontearsisasingledirectmrarthrographyseriesinaberpositionasaccurateasconventionalmrarthrography
AT vanderhulstvictorpm detectionofpartialthicknesssupraspinatustendontearsisasingledirectmrarthrographyseriesinaberpositionasaccurateasconventionalmrarthrography
AT willemswjaap detectionofpartialthicknesssupraspinatustendontearsisasingledirectmrarthrographyseriesinaberpositionasaccurateasconventionalmrarthrography
AT bipatshandra detectionofpartialthicknesssupraspinatustendontearsisasingledirectmrarthrographyseriesinaberpositionasaccurateasconventionalmrarthrography
AT vanderwoudehenkjan detectionofpartialthicknesssupraspinatustendontearsisasingledirectmrarthrographyseriesinaberpositionasaccurateasconventionalmrarthrography