Use Of A Unique Long Pre-curved Sheath To Facilitate Femoral Placement Of Coronary Sinus Catheters

METHODS: Catheterization of the coronary sinus (CS) from the femoral vein is widely used during electrophysiologic procedures. Access to the CS may be difficult. To address this problem we explored the utility of a long pre-formed (SAFL™) sheath in a cohort of consecutive patients requiring CS cannu...

Descripción completa

Detalles Bibliográficos
Autores principales: Shandling, Adrian H, Rieders, Daniel, Edwards, Melanie
Formato: Texto
Lenguaje:English
Publicado: Indian Heart Rhythm Society 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2735156/
https://www.ncbi.nlm.nih.gov/pubmed/19763192
_version_ 1782171247037120512
author Shandling, Adrian H
Rieders, Daniel
Edwards, Melanie
author_facet Shandling, Adrian H
Rieders, Daniel
Edwards, Melanie
author_sort Shandling, Adrian H
collection PubMed
description METHODS: Catheterization of the coronary sinus (CS) from the femoral vein is widely used during electrophysiologic procedures. Access to the CS may be difficult. To address this problem we explored the utility of a long pre-formed (SAFL™) sheath in a cohort of consecutive patients requiring CS cannulation in the electrophysiology laboratory. This unique sheath has distal curvatures in 2 planes, potentially facilitating CS cannulation. RESULTS: 68 patients were studied with an average age of 63± 16 years. In twelve patients (18%), standard femoral CS cannulation was ineffective. In six of these patients, the SAFL™ sheath allowed for cannulation, and in six the subclavian approach was required. There were no significant differences in age, left ventricular ejection fraction, or echocardiographically estimated pulmonary artery systolic pressure between the various subgroups. There was a trend towards a larger left atrial size in the atrial flutter group (46mm± 7.9) versus all others (40.6mm± 6.3, P=.076). Left atrial size was 37 mm in the femoral sheath-requiring group versus 44 mm in all others (P=NS). CONCLUSION: Utilization of a unique commercially available long preformed sheath helps to provide femoral CS catheter access in selected cases in the electrophysiology laboratory.
format Text
id pubmed-2735156
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Indian Heart Rhythm Society
record_format MEDLINE/PubMed
spelling pubmed-27351562009-09-18 Use Of A Unique Long Pre-curved Sheath To Facilitate Femoral Placement Of Coronary Sinus Catheters Shandling, Adrian H Rieders, Daniel Edwards, Melanie Indian Pacing Electrophysiol J Original Article METHODS: Catheterization of the coronary sinus (CS) from the femoral vein is widely used during electrophysiologic procedures. Access to the CS may be difficult. To address this problem we explored the utility of a long pre-formed (SAFL™) sheath in a cohort of consecutive patients requiring CS cannulation in the electrophysiology laboratory. This unique sheath has distal curvatures in 2 planes, potentially facilitating CS cannulation. RESULTS: 68 patients were studied with an average age of 63± 16 years. In twelve patients (18%), standard femoral CS cannulation was ineffective. In six of these patients, the SAFL™ sheath allowed for cannulation, and in six the subclavian approach was required. There were no significant differences in age, left ventricular ejection fraction, or echocardiographically estimated pulmonary artery systolic pressure between the various subgroups. There was a trend towards a larger left atrial size in the atrial flutter group (46mm± 7.9) versus all others (40.6mm± 6.3, P=.076). Left atrial size was 37 mm in the femoral sheath-requiring group versus 44 mm in all others (P=NS). CONCLUSION: Utilization of a unique commercially available long preformed sheath helps to provide femoral CS catheter access in selected cases in the electrophysiology laboratory. Indian Heart Rhythm Society 2009-09-01 /pmc/articles/PMC2735156/ /pubmed/19763192 Text en Copyright: © 2009 Shandling et al. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Shandling, Adrian H
Rieders, Daniel
Edwards, Melanie
Use Of A Unique Long Pre-curved Sheath To Facilitate Femoral Placement Of Coronary Sinus Catheters
title Use Of A Unique Long Pre-curved Sheath To Facilitate Femoral Placement Of Coronary Sinus Catheters
title_full Use Of A Unique Long Pre-curved Sheath To Facilitate Femoral Placement Of Coronary Sinus Catheters
title_fullStr Use Of A Unique Long Pre-curved Sheath To Facilitate Femoral Placement Of Coronary Sinus Catheters
title_full_unstemmed Use Of A Unique Long Pre-curved Sheath To Facilitate Femoral Placement Of Coronary Sinus Catheters
title_short Use Of A Unique Long Pre-curved Sheath To Facilitate Femoral Placement Of Coronary Sinus Catheters
title_sort use of a unique long pre-curved sheath to facilitate femoral placement of coronary sinus catheters
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2735156/
https://www.ncbi.nlm.nih.gov/pubmed/19763192
work_keys_str_mv AT shandlingadrianh useofauniquelongprecurvedsheathtofacilitatefemoralplacementofcoronarysinuscatheters
AT riedersdaniel useofauniquelongprecurvedsheathtofacilitatefemoralplacementofcoronarysinuscatheters
AT edwardsmelanie useofauniquelongprecurvedsheathtofacilitatefemoralplacementofcoronarysinuscatheters