Cargando…

Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report

INTRODUCTION: High energy tibial plateau fractures along with calcaneal fractures individually produce several challenges for the orthopaedic surgeon. The principles of bony reconstruction include anatomic reduction and rigid internal fixation of intra-articular fractures and accurate restoration of...

Descripción completa

Detalles Bibliográficos
Autores principales: Dhar, Shabir Ahmed, Butt, Mohammed Farooq, Ali, Murtaza Fazal, Mir, Mohammed Ramzan, Kawoosa, Altaf Ahmed
Formato: Texto
Lenguaje:English
Publicado: Cases Network Ltd 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2740103/
https://www.ncbi.nlm.nih.gov/pubmed/19830021
http://dx.doi.org/10.1186/1757-1626-2-7869
_version_ 1782171653800722432
author Dhar, Shabir Ahmed
Butt, Mohammed Farooq
Ali, Murtaza Fazal
Mir, Mohammed Ramzan
Kawoosa, Altaf Ahmed
author_facet Dhar, Shabir Ahmed
Butt, Mohammed Farooq
Ali, Murtaza Fazal
Mir, Mohammed Ramzan
Kawoosa, Altaf Ahmed
author_sort Dhar, Shabir Ahmed
collection PubMed
description INTRODUCTION: High energy tibial plateau fractures along with calcaneal fractures individually produce several challenges for the orthopaedic surgeon. The principles of bony reconstruction include anatomic reduction and rigid internal fixation of intra-articular fractures and accurate restoration of the coronal, sagittal and transverse mechanical axes. Due to the tenuous nature of the soft tissue and devitalisation of the comminuted fragments with open reduction, external fixation of type 6 tibial plateau fractures is recommended. We report a case with ipsilateral high energy tibial plateau and calcaneal fractures both of which were managed with an ilizarov ring fixator. CASE PRESENTATION: A 55-year-old Kashmiri female presented to our department with an ipsilateral fracture of the tibial plateau and the calcaneum. Both were closed reduced and stabilized with an ilizarov ring fixator. CONCLUSION: The circular wire fixator provides a viable method to manage such fractures especially if they are co existent. This is especially true in situations where the soft tissue is compromised.
format Text
id pubmed-2740103
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Cases Network Ltd
record_format MEDLINE/PubMed
spelling pubmed-27401032009-10-14 Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report Dhar, Shabir Ahmed Butt, Mohammed Farooq Ali, Murtaza Fazal Mir, Mohammed Ramzan Kawoosa, Altaf Ahmed Cases J Case report INTRODUCTION: High energy tibial plateau fractures along with calcaneal fractures individually produce several challenges for the orthopaedic surgeon. The principles of bony reconstruction include anatomic reduction and rigid internal fixation of intra-articular fractures and accurate restoration of the coronal, sagittal and transverse mechanical axes. Due to the tenuous nature of the soft tissue and devitalisation of the comminuted fragments with open reduction, external fixation of type 6 tibial plateau fractures is recommended. We report a case with ipsilateral high energy tibial plateau and calcaneal fractures both of which were managed with an ilizarov ring fixator. CASE PRESENTATION: A 55-year-old Kashmiri female presented to our department with an ipsilateral fracture of the tibial plateau and the calcaneum. Both were closed reduced and stabilized with an ilizarov ring fixator. CONCLUSION: The circular wire fixator provides a viable method to manage such fractures especially if they are co existent. This is especially true in situations where the soft tissue is compromised. Cases Network Ltd 2009-06-03 /pmc/articles/PMC2740103/ /pubmed/19830021 http://dx.doi.org/10.1186/1757-1626-2-7869 Text en © 2009 Dhar et al.; licensee Cases Network Ltd. http://creativecommons.org/licenses/by/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case report
Dhar, Shabir Ahmed
Butt, Mohammed Farooq
Ali, Murtaza Fazal
Mir, Mohammed Ramzan
Kawoosa, Altaf Ahmed
Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report
title Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report
title_full Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report
title_fullStr Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report
title_full_unstemmed Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report
title_short Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report
title_sort treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2740103/
https://www.ncbi.nlm.nih.gov/pubmed/19830021
http://dx.doi.org/10.1186/1757-1626-2-7869
work_keys_str_mv AT dharshabirahmed treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport
AT buttmohammedfarooq treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport
AT alimurtazafazal treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport
AT mirmohammedramzan treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport
AT kawoosaaltafahmed treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport