Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report
INTRODUCTION: High energy tibial plateau fractures along with calcaneal fractures individually produce several challenges for the orthopaedic surgeon. The principles of bony reconstruction include anatomic reduction and rigid internal fixation of intra-articular fractures and accurate restoration of...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Cases Network Ltd
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2740103/ https://www.ncbi.nlm.nih.gov/pubmed/19830021 http://dx.doi.org/10.1186/1757-1626-2-7869 |
_version_ | 1782171653800722432 |
---|---|
author | Dhar, Shabir Ahmed Butt, Mohammed Farooq Ali, Murtaza Fazal Mir, Mohammed Ramzan Kawoosa, Altaf Ahmed |
author_facet | Dhar, Shabir Ahmed Butt, Mohammed Farooq Ali, Murtaza Fazal Mir, Mohammed Ramzan Kawoosa, Altaf Ahmed |
author_sort | Dhar, Shabir Ahmed |
collection | PubMed |
description | INTRODUCTION: High energy tibial plateau fractures along with calcaneal fractures individually produce several challenges for the orthopaedic surgeon. The principles of bony reconstruction include anatomic reduction and rigid internal fixation of intra-articular fractures and accurate restoration of the coronal, sagittal and transverse mechanical axes. Due to the tenuous nature of the soft tissue and devitalisation of the comminuted fragments with open reduction, external fixation of type 6 tibial plateau fractures is recommended. We report a case with ipsilateral high energy tibial plateau and calcaneal fractures both of which were managed with an ilizarov ring fixator. CASE PRESENTATION: A 55-year-old Kashmiri female presented to our department with an ipsilateral fracture of the tibial plateau and the calcaneum. Both were closed reduced and stabilized with an ilizarov ring fixator. CONCLUSION: The circular wire fixator provides a viable method to manage such fractures especially if they are co existent. This is especially true in situations where the soft tissue is compromised. |
format | Text |
id | pubmed-2740103 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Cases Network Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-27401032009-10-14 Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report Dhar, Shabir Ahmed Butt, Mohammed Farooq Ali, Murtaza Fazal Mir, Mohammed Ramzan Kawoosa, Altaf Ahmed Cases J Case report INTRODUCTION: High energy tibial plateau fractures along with calcaneal fractures individually produce several challenges for the orthopaedic surgeon. The principles of bony reconstruction include anatomic reduction and rigid internal fixation of intra-articular fractures and accurate restoration of the coronal, sagittal and transverse mechanical axes. Due to the tenuous nature of the soft tissue and devitalisation of the comminuted fragments with open reduction, external fixation of type 6 tibial plateau fractures is recommended. We report a case with ipsilateral high energy tibial plateau and calcaneal fractures both of which were managed with an ilizarov ring fixator. CASE PRESENTATION: A 55-year-old Kashmiri female presented to our department with an ipsilateral fracture of the tibial plateau and the calcaneum. Both were closed reduced and stabilized with an ilizarov ring fixator. CONCLUSION: The circular wire fixator provides a viable method to manage such fractures especially if they are co existent. This is especially true in situations where the soft tissue is compromised. Cases Network Ltd 2009-06-03 /pmc/articles/PMC2740103/ /pubmed/19830021 http://dx.doi.org/10.1186/1757-1626-2-7869 Text en © 2009 Dhar et al.; licensee Cases Network Ltd. http://creativecommons.org/licenses/by/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case report Dhar, Shabir Ahmed Butt, Mohammed Farooq Ali, Murtaza Fazal Mir, Mohammed Ramzan Kawoosa, Altaf Ahmed Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report |
title | Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report |
title_full | Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report |
title_fullStr | Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report |
title_full_unstemmed | Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report |
title_short | Treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report |
title_sort | treatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report |
topic | Case report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2740103/ https://www.ncbi.nlm.nih.gov/pubmed/19830021 http://dx.doi.org/10.1186/1757-1626-2-7869 |
work_keys_str_mv | AT dharshabirahmed treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport AT buttmohammedfarooq treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport AT alimurtazafazal treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport AT mirmohammedramzan treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport AT kawoosaaltafahmed treatmentofipsilateralhighenergytibialplateauandcalcanealfracturesbyacircularwirefixatoracasereport |