Cargando…
Effect of Thermo-mechanical Load Cycling on Microleakage in Class II Ormocer Restorations
OBJECTIVES: The objective of this in vitro study was to evaluate the marginal sealing ability of an ormocer in comparison with a hybrid composite when using thermocycling and load cycling procedures together in the study design. METHODS: Modified proximal Class II cavities were prepared on the mesia...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Dental Investigations Society
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2741191/ https://www.ncbi.nlm.nih.gov/pubmed/19756194 |
Sumario: | OBJECTIVES: The objective of this in vitro study was to evaluate the marginal sealing ability of an ormocer in comparison with a hybrid composite when using thermocycling and load cycling procedures together in the study design. METHODS: Modified proximal Class II cavities were prepared on the mesial and distal surfaces of twenty-two human premolars. Each tooth was restored with Admira and contralaterally with TPH Spectrum. Half of all of the teeth were subjected to thermo-mechanical load cycling. After dye penetration, longitudinal sections in mesio-distal direction were prepared and examined under a stereomicroscope. Data were analyzed with Mann Whitney U test. RESULTS: The results showed that the thermo-mechanical load cycling caused a statistically significant increase in gingival microleakage when compared with the non-thermocycled and non-loaded restorations for both the materials Admira (P=0.006) and TPH Spectrum (P=0.023). CONCLUSIONS: Simultaneous load cycling and thermocycling are decisive factors in the in vitro assessment of gingival microleakage, which still remains to be a clinical problem even with the ormocer system Admira. |
---|