Cargando…

Fixation of subtrochanteric fractures: Does a technical optimization of the dynamic hip screw application improve the results?

The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult for the treating surgeon. The preferred type of device is a matter of debate. Increased understanding of mechanical characteristics of the dynamic hip screw (DHS) has reduced...

Descripción completa

Detalles Bibliográficos
Autor principal: Massoud, Elsayed Ibraheem Elsayed
Formato: Texto
Lenguaje:English
Publicado: Springer Milan 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2746270/
https://www.ncbi.nlm.nih.gov/pubmed/19504040
http://dx.doi.org/10.1007/s11751-009-0058-z
_version_ 1782172031476826112
author Massoud, Elsayed Ibraheem Elsayed
author_facet Massoud, Elsayed Ibraheem Elsayed
author_sort Massoud, Elsayed Ibraheem Elsayed
collection PubMed
description The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult for the treating surgeon. The preferred type of device is a matter of debate. Increased understanding of mechanical characteristics of the dynamic hip screw (DHS) has reduced the incidence of complications. Our hypothesis is based on the technical optimization of the DHS application. We prospectively studied 37 patients with subtrochanteric fractures with a mean age of 42.9 years. We utilized a two-stage protocol: initially, conversion of the comminuted fractures into two part fractures; then application of the implant with a technique that allowed dynamization of the DHS. Clinical and radiographic data were used to assess the outcome at 12 months. Fracture healing was obtained for all cases in a mean time of 11.64 weeks. One patient had 1.5 cm shortening of the injured limb. No implant failure was reported. All patients resumed pre-injury activities of daily living. It was concluded that the patients who were treated with the technical optimization of the DHS application achieved a close-to-normal anatomy following surgery and maintained this state throughout the follow-up period.
format Text
id pubmed-2746270
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Springer Milan
record_format MEDLINE/PubMed
spelling pubmed-27462702009-09-23 Fixation of subtrochanteric fractures: Does a technical optimization of the dynamic hip screw application improve the results? Massoud, Elsayed Ibraheem Elsayed Strategies Trauma Limb Reconstr Original Article The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult for the treating surgeon. The preferred type of device is a matter of debate. Increased understanding of mechanical characteristics of the dynamic hip screw (DHS) has reduced the incidence of complications. Our hypothesis is based on the technical optimization of the DHS application. We prospectively studied 37 patients with subtrochanteric fractures with a mean age of 42.9 years. We utilized a two-stage protocol: initially, conversion of the comminuted fractures into two part fractures; then application of the implant with a technique that allowed dynamization of the DHS. Clinical and radiographic data were used to assess the outcome at 12 months. Fracture healing was obtained for all cases in a mean time of 11.64 weeks. One patient had 1.5 cm shortening of the injured limb. No implant failure was reported. All patients resumed pre-injury activities of daily living. It was concluded that the patients who were treated with the technical optimization of the DHS application achieved a close-to-normal anatomy following surgery and maintained this state throughout the follow-up period. Springer Milan 2009-06-06 2009-10 /pmc/articles/PMC2746270/ /pubmed/19504040 http://dx.doi.org/10.1007/s11751-009-0058-z Text en © Springer-Verlag 2009
spellingShingle Original Article
Massoud, Elsayed Ibraheem Elsayed
Fixation of subtrochanteric fractures: Does a technical optimization of the dynamic hip screw application improve the results?
title Fixation of subtrochanteric fractures: Does a technical optimization of the dynamic hip screw application improve the results?
title_full Fixation of subtrochanteric fractures: Does a technical optimization of the dynamic hip screw application improve the results?
title_fullStr Fixation of subtrochanteric fractures: Does a technical optimization of the dynamic hip screw application improve the results?
title_full_unstemmed Fixation of subtrochanteric fractures: Does a technical optimization of the dynamic hip screw application improve the results?
title_short Fixation of subtrochanteric fractures: Does a technical optimization of the dynamic hip screw application improve the results?
title_sort fixation of subtrochanteric fractures: does a technical optimization of the dynamic hip screw application improve the results?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2746270/
https://www.ncbi.nlm.nih.gov/pubmed/19504040
http://dx.doi.org/10.1007/s11751-009-0058-z
work_keys_str_mv AT massoudelsayedibraheemelsayed fixationofsubtrochantericfracturesdoesatechnicaloptimizationofthedynamichipscrewapplicationimprovetheresults