Cargando…

Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge

The optical setup and the performance of a prototype UV/Vis multiwavelength analytical ultracentrifuge (MWL-AUC) is described and compared to the commercially available Optima XL-A from Beckman Coulter. Slight modifications have been made to the optical path of the MWL-AUC. With respect to wavelengt...

Descripción completa

Detalles Bibliográficos
Autores principales: Strauss, Holger M., Karabudak, Engin, Bhattacharyya, Saroj, Kretzschmar, Andreas, Wohlleben, Wendel, Cölfen, Helmut
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2755732/
https://www.ncbi.nlm.nih.gov/pubmed/19816525
http://dx.doi.org/10.1007/s00396-007-1815-5
_version_ 1782172457569878016
author Strauss, Holger M.
Karabudak, Engin
Bhattacharyya, Saroj
Kretzschmar, Andreas
Wohlleben, Wendel
Cölfen, Helmut
author_facet Strauss, Holger M.
Karabudak, Engin
Bhattacharyya, Saroj
Kretzschmar, Andreas
Wohlleben, Wendel
Cölfen, Helmut
author_sort Strauss, Holger M.
collection PubMed
description The optical setup and the performance of a prototype UV/Vis multiwavelength analytical ultracentrifuge (MWL-AUC) is described and compared to the commercially available Optima XL-A from Beckman Coulter. Slight modifications have been made to the optical path of the MWL-AUC. With respect to wavelength accuracy and radial resolution, the new MWL-AUC is found to be comparable to the existing XL-A. Absorbance accuracy is dependent on the light intensity available at the detection wavelength as well as the intrinsic noise of the data. Measurements from single flashes of light are more noisy for the MWL-AUC, potentially due to the absence of flash-to-flash normalization in the current design. However, the possibility of both wavelength and scan averaging can compensate for this and still give much faster scan rates than the XL-A. Some further improvements of the existing design are suggested based on these findings.
format Text
id pubmed-2755732
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-27557322009-10-07 Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge Strauss, Holger M. Karabudak, Engin Bhattacharyya, Saroj Kretzschmar, Andreas Wohlleben, Wendel Cölfen, Helmut Colloid Polym Sci Original Contribution The optical setup and the performance of a prototype UV/Vis multiwavelength analytical ultracentrifuge (MWL-AUC) is described and compared to the commercially available Optima XL-A from Beckman Coulter. Slight modifications have been made to the optical path of the MWL-AUC. With respect to wavelength accuracy and radial resolution, the new MWL-AUC is found to be comparable to the existing XL-A. Absorbance accuracy is dependent on the light intensity available at the detection wavelength as well as the intrinsic noise of the data. Measurements from single flashes of light are more noisy for the MWL-AUC, potentially due to the absence of flash-to-flash normalization in the current design. However, the possibility of both wavelength and scan averaging can compensate for this and still give much faster scan rates than the XL-A. Some further improvements of the existing design are suggested based on these findings. Springer-Verlag 2007-12-19 2008-02 /pmc/articles/PMC2755732/ /pubmed/19816525 http://dx.doi.org/10.1007/s00396-007-1815-5 Text en © Springer-Verlag 2007
spellingShingle Original Contribution
Strauss, Holger M.
Karabudak, Engin
Bhattacharyya, Saroj
Kretzschmar, Andreas
Wohlleben, Wendel
Cölfen, Helmut
Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge
title Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge
title_full Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge
title_fullStr Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge
title_full_unstemmed Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge
title_short Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge
title_sort performance of a fast fiber based uv/vis multiwavelength detector for the analytical ultracentrifuge
topic Original Contribution
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2755732/
https://www.ncbi.nlm.nih.gov/pubmed/19816525
http://dx.doi.org/10.1007/s00396-007-1815-5
work_keys_str_mv AT straussholgerm performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge
AT karabudakengin performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge
AT bhattacharyyasaroj performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge
AT kretzschmarandreas performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge
AT wohllebenwendel performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge
AT colfenhelmut performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge