Cargando…
Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge
The optical setup and the performance of a prototype UV/Vis multiwavelength analytical ultracentrifuge (MWL-AUC) is described and compared to the commercially available Optima XL-A from Beckman Coulter. Slight modifications have been made to the optical path of the MWL-AUC. With respect to wavelengt...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2007
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2755732/ https://www.ncbi.nlm.nih.gov/pubmed/19816525 http://dx.doi.org/10.1007/s00396-007-1815-5 |
_version_ | 1782172457569878016 |
---|---|
author | Strauss, Holger M. Karabudak, Engin Bhattacharyya, Saroj Kretzschmar, Andreas Wohlleben, Wendel Cölfen, Helmut |
author_facet | Strauss, Holger M. Karabudak, Engin Bhattacharyya, Saroj Kretzschmar, Andreas Wohlleben, Wendel Cölfen, Helmut |
author_sort | Strauss, Holger M. |
collection | PubMed |
description | The optical setup and the performance of a prototype UV/Vis multiwavelength analytical ultracentrifuge (MWL-AUC) is described and compared to the commercially available Optima XL-A from Beckman Coulter. Slight modifications have been made to the optical path of the MWL-AUC. With respect to wavelength accuracy and radial resolution, the new MWL-AUC is found to be comparable to the existing XL-A. Absorbance accuracy is dependent on the light intensity available at the detection wavelength as well as the intrinsic noise of the data. Measurements from single flashes of light are more noisy for the MWL-AUC, potentially due to the absence of flash-to-flash normalization in the current design. However, the possibility of both wavelength and scan averaging can compensate for this and still give much faster scan rates than the XL-A. Some further improvements of the existing design are suggested based on these findings. |
format | Text |
id | pubmed-2755732 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2007 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-27557322009-10-07 Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge Strauss, Holger M. Karabudak, Engin Bhattacharyya, Saroj Kretzschmar, Andreas Wohlleben, Wendel Cölfen, Helmut Colloid Polym Sci Original Contribution The optical setup and the performance of a prototype UV/Vis multiwavelength analytical ultracentrifuge (MWL-AUC) is described and compared to the commercially available Optima XL-A from Beckman Coulter. Slight modifications have been made to the optical path of the MWL-AUC. With respect to wavelength accuracy and radial resolution, the new MWL-AUC is found to be comparable to the existing XL-A. Absorbance accuracy is dependent on the light intensity available at the detection wavelength as well as the intrinsic noise of the data. Measurements from single flashes of light are more noisy for the MWL-AUC, potentially due to the absence of flash-to-flash normalization in the current design. However, the possibility of both wavelength and scan averaging can compensate for this and still give much faster scan rates than the XL-A. Some further improvements of the existing design are suggested based on these findings. Springer-Verlag 2007-12-19 2008-02 /pmc/articles/PMC2755732/ /pubmed/19816525 http://dx.doi.org/10.1007/s00396-007-1815-5 Text en © Springer-Verlag 2007 |
spellingShingle | Original Contribution Strauss, Holger M. Karabudak, Engin Bhattacharyya, Saroj Kretzschmar, Andreas Wohlleben, Wendel Cölfen, Helmut Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge |
title | Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge |
title_full | Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge |
title_fullStr | Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge |
title_full_unstemmed | Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge |
title_short | Performance of a fast fiber based UV/Vis multiwavelength detector for the analytical ultracentrifuge |
title_sort | performance of a fast fiber based uv/vis multiwavelength detector for the analytical ultracentrifuge |
topic | Original Contribution |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2755732/ https://www.ncbi.nlm.nih.gov/pubmed/19816525 http://dx.doi.org/10.1007/s00396-007-1815-5 |
work_keys_str_mv | AT straussholgerm performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge AT karabudakengin performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge AT bhattacharyyasaroj performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge AT kretzschmarandreas performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge AT wohllebenwendel performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge AT colfenhelmut performanceofafastfiberbaseduvvismultiwavelengthdetectorfortheanalyticalultracentrifuge |