Cargando…

Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser

We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired...

Descripción completa

Detalles Bibliográficos
Autores principales: Verkouteren, R. Michael, Verkouteren, Jennifer R.
Formato: Texto
Lenguaje:English
Publicado: American Chemical Society 2009
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2762308/
https://www.ncbi.nlm.nih.gov/pubmed/19824716
http://dx.doi.org/10.1021/ac901563j
_version_ 1782172911757426688
author Verkouteren, R. Michael
Verkouteren, Jennifer R.
author_facet Verkouteren, R. Michael
Verkouteren, Jennifer R.
author_sort Verkouteren, R. Michael
collection PubMed
description We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (u(c)) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 μg (1490 droplets) with u(c) = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies.
format Text
id pubmed-2762308
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-27623082009-10-15 Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser Verkouteren, R. Michael Verkouteren, Jennifer R. Anal Chem We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (u(c)) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 μg (1490 droplets) with u(c) = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies. American Chemical Society 2009-09-22 2009-10-15 /pmc/articles/PMC2762308/ /pubmed/19824716 http://dx.doi.org/10.1021/ac901563j Text en Copyright © 2009 U.S. Government http://pubs.acs.org This is an open-access article distributed under the ACS AuthorChoice Terms & Conditions. Any use of this article, must conform to the terms of that license which are available at http://pubs.acs.org.
spellingShingle Verkouteren, R. Michael
Verkouteren, Jennifer R.
Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser
title Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser
title_full Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser
title_fullStr Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser
title_full_unstemmed Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser
title_short Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser
title_sort inkjet metrology: high-accuracy mass measurements of microdroplets produced by a drop-on-demand dispenser
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2762308/
https://www.ncbi.nlm.nih.gov/pubmed/19824716
http://dx.doi.org/10.1021/ac901563j
work_keys_str_mv AT verkouterenrmichael inkjetmetrologyhighaccuracymassmeasurementsofmicrodropletsproducedbyadropondemanddispenser
AT verkouterenjenniferr inkjetmetrologyhighaccuracymassmeasurementsofmicrodropletsproducedbyadropondemanddispenser