Cargando…
Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser
We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2009
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2762308/ https://www.ncbi.nlm.nih.gov/pubmed/19824716 http://dx.doi.org/10.1021/ac901563j |
_version_ | 1782172911757426688 |
---|---|
author | Verkouteren, R. Michael Verkouteren, Jennifer R. |
author_facet | Verkouteren, R. Michael Verkouteren, Jennifer R. |
author_sort | Verkouteren, R. Michael |
collection | PubMed |
description | We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (u(c)) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 μg (1490 droplets) with u(c) = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies. |
format | Text |
id | pubmed-2762308 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-27623082009-10-15 Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser Verkouteren, R. Michael Verkouteren, Jennifer R. Anal Chem We describe gravimetric methods for measuring the mass of droplets generated by a drop-on-demand (DOD) microdispenser. Droplets are deposited, either continuously at a known frequency or as a burst of known number, into a cylinder positioned on a submicrogram balance. Mass measurements are acquired precisely by computer, and results are corrected for evaporation. Capabilities are demonstrated using isobutyl alcohol droplets. For ejection rates greater than 100 Hz, the repeatability of droplet mass measurements was 0.2%, while the combined relative standard uncertainty (u(c)) was 0.9%. When bursts of droplets were dispensed, the limit of quantitation was 72 μg (1490 droplets) with u(c) = 1.0%. Individual droplet size in a burst was evaluated by high-speed videography. Diameters were consistent from the tenth droplet onward, and the mass of an individual droplet was best estimated by the average droplet mass with a combined uncertainty of about 1%. Diameters of the first several droplets were anomalous, but their contribution was accounted for when dispensing bursts. Above the limits of quantitation, the gravimetric methods provided statistically equivalent results and permit detailed study of operational factors that influence droplet mass during dispensing, including the development of reliable microassays and standard materials using DOD technologies. American Chemical Society 2009-09-22 2009-10-15 /pmc/articles/PMC2762308/ /pubmed/19824716 http://dx.doi.org/10.1021/ac901563j Text en Copyright © 2009 U.S. Government http://pubs.acs.org This is an open-access article distributed under the ACS AuthorChoice Terms & Conditions. Any use of this article, must conform to the terms of that license which are available at http://pubs.acs.org. |
spellingShingle | Verkouteren, R. Michael Verkouteren, Jennifer R. Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser |
title | Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser |
title_full | Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser |
title_fullStr | Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser |
title_full_unstemmed | Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser |
title_short | Inkjet Metrology: High-Accuracy Mass Measurements of Microdroplets Produced by a Drop-on-Demand Dispenser |
title_sort | inkjet metrology: high-accuracy mass measurements of microdroplets produced by a drop-on-demand dispenser |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2762308/ https://www.ncbi.nlm.nih.gov/pubmed/19824716 http://dx.doi.org/10.1021/ac901563j |
work_keys_str_mv | AT verkouterenrmichael inkjetmetrologyhighaccuracymassmeasurementsofmicrodropletsproducedbyadropondemanddispenser AT verkouterenjenniferr inkjetmetrologyhighaccuracymassmeasurementsofmicrodropletsproducedbyadropondemanddispenser |