Cargando…

The INDUS knee prosthesis – Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up

BACKGROUND: The anatomical and morphological differences and high-flexion daily activities in the Asian population have since ever prompted for development of customized knee replacement systems. INDUS knee system has advantages both of high-flex designs and is developed by keeping the anatomical va...

Descripción completa

Detalles Bibliográficos
Autores principales: Sancheti, Kantilal H, Laud, Nandu S, Bhende, Harish, Reddy, Gurava, Pramod, Neema, Mani, Joseph N
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2762555/
https://www.ncbi.nlm.nih.gov/pubmed/19838387
http://dx.doi.org/10.4103/0019-5413.55976
_version_ 1782172939129454592
author Sancheti, Kantilal H
Laud, Nandu S
Bhende, Harish
Reddy, Gurava
Pramod, Neema
Mani, Joseph N
author_facet Sancheti, Kantilal H
Laud, Nandu S
Bhende, Harish
Reddy, Gurava
Pramod, Neema
Mani, Joseph N
author_sort Sancheti, Kantilal H
collection PubMed
description BACKGROUND: The anatomical and morphological differences and high-flexion daily activities in the Asian population have since ever prompted for development of customized knee replacement systems. INDUS knee system has advantages both of high-flex designs and is developed by keeping the anatomical variations of the native population in mind. The purpose of this study is to analyze the 2-year follow-up results using the INDUS prosthesis. MATERIALS AND METHODS: Two hundred and ninety-seven knees in 276 patients were prospectively analyzed. There were 65 men (72 knees) and 211 (225 knees) women with a mean age of 64.56 years. Two hundred and forty-five knees had primary osteoarthritis, 48 knees had rheumatoid arthritis, and four knees had post-traumatic arthritis. Clinical parameters, including the Knee Society scores (knee score and function score), range of motion, post-operative anterior knee pain, and complications were recorded. Pre- and post-operative serial radiographs were analyzed for limb alignment, component positioning, and evidence of loosening. RESULTS: The patients were followed-up for an average of 2.59 years (range, 2–3.3 years). The mean knee score and the mean function score were significantly improved from a pre-operative value of 39.4 points and 46.7 points to a post-operative value of 87 points and 86 points, respectively (P value <0.05). Two hundred and thirty four knees had no anterior knee pain while 63 knees had mild to moderate pain, but none of the patients requested any intervention for the same. Of the 276 patients (297 knees), 79 knees had flexion above 140°, 167 had a flexion range of 130–140°, 27 had a flexion range of 100–130°, and 24 knees had a flexion < 100°, with the mean range of movement being 132.9°. Improvements in the range of movement were retained over time and a total of 205 patients (224 knees, 75.7%) could squat or sit cross-legged at the final follow-up. The mean tibiofemoral angle was 8.5°±6.9° of varus pre-operatively and 5.4°±2.2° of valgus (3–7° of valgus) at the final follow-up, with no loss of alignment noted in any case. One knee underwent revision for late infection while another knee had periprosthetic supracondylar fracture treated with plate fixation. CONCLUSIONS: Use of the INDUS knee prosthesis has a favorable short-term outcome, with a mean range of 135° flexion and excellent knee scores.
format Text
id pubmed-2762555
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-27625552009-10-16 The INDUS knee prosthesis – Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up Sancheti, Kantilal H Laud, Nandu S Bhende, Harish Reddy, Gurava Pramod, Neema Mani, Joseph N Indian J Orthop Original Article BACKGROUND: The anatomical and morphological differences and high-flexion daily activities in the Asian population have since ever prompted for development of customized knee replacement systems. INDUS knee system has advantages both of high-flex designs and is developed by keeping the anatomical variations of the native population in mind. The purpose of this study is to analyze the 2-year follow-up results using the INDUS prosthesis. MATERIALS AND METHODS: Two hundred and ninety-seven knees in 276 patients were prospectively analyzed. There were 65 men (72 knees) and 211 (225 knees) women with a mean age of 64.56 years. Two hundred and forty-five knees had primary osteoarthritis, 48 knees had rheumatoid arthritis, and four knees had post-traumatic arthritis. Clinical parameters, including the Knee Society scores (knee score and function score), range of motion, post-operative anterior knee pain, and complications were recorded. Pre- and post-operative serial radiographs were analyzed for limb alignment, component positioning, and evidence of loosening. RESULTS: The patients were followed-up for an average of 2.59 years (range, 2–3.3 years). The mean knee score and the mean function score were significantly improved from a pre-operative value of 39.4 points and 46.7 points to a post-operative value of 87 points and 86 points, respectively (P value <0.05). Two hundred and thirty four knees had no anterior knee pain while 63 knees had mild to moderate pain, but none of the patients requested any intervention for the same. Of the 276 patients (297 knees), 79 knees had flexion above 140°, 167 had a flexion range of 130–140°, 27 had a flexion range of 100–130°, and 24 knees had a flexion < 100°, with the mean range of movement being 132.9°. Improvements in the range of movement were retained over time and a total of 205 patients (224 knees, 75.7%) could squat or sit cross-legged at the final follow-up. The mean tibiofemoral angle was 8.5°±6.9° of varus pre-operatively and 5.4°±2.2° of valgus (3–7° of valgus) at the final follow-up, with no loss of alignment noted in any case. One knee underwent revision for late infection while another knee had periprosthetic supracondylar fracture treated with plate fixation. CONCLUSIONS: Use of the INDUS knee prosthesis has a favorable short-term outcome, with a mean range of 135° flexion and excellent knee scores. Medknow Publications 2009 /pmc/articles/PMC2762555/ /pubmed/19838387 http://dx.doi.org/10.4103/0019-5413.55976 Text en © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Sancheti, Kantilal H
Laud, Nandu S
Bhende, Harish
Reddy, Gurava
Pramod, Neema
Mani, Joseph N
The INDUS knee prosthesis – Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up
title The INDUS knee prosthesis – Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up
title_full The INDUS knee prosthesis – Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up
title_fullStr The INDUS knee prosthesis – Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up
title_full_unstemmed The INDUS knee prosthesis – Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up
title_short The INDUS knee prosthesis – Prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up
title_sort indus knee prosthesis – prospective multicentric trial of a posteriorly stabilized high-flex design: 2 years follow-up
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2762555/
https://www.ncbi.nlm.nih.gov/pubmed/19838387
http://dx.doi.org/10.4103/0019-5413.55976
work_keys_str_mv AT sanchetikantilalh theinduskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT laudnandus theinduskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT bhendeharish theinduskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT reddygurava theinduskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT pramodneema theinduskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT manijosephn theinduskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT sanchetikantilalh induskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT laudnandus induskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT bhendeharish induskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT reddygurava induskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT pramodneema induskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup
AT manijosephn induskneeprosthesisprospectivemulticentrictrialofaposteriorlystabilizedhighflexdesign2yearsfollowup