Cargando…

Impact of continuous positive airway pressure treatment on left atrial volume and function in patients with obstructive sleep apnoea assessed by real-time three-dimensional echocardiography

BACKGROUND: Obstructive sleep apnoea (OSA) has been reported as a predictor of left ventricle (LV) diastolic dysfunction and left atrium (LA) remodelling. The aim of this study is to evaluate the impact of OSA treatment with a continuous positive airway pressure device (CPAP) on the LA volume and fu...

Descripción completa

Detalles Bibliográficos
Autores principales: Oliveira, W, Campos, O, Cintra, F, Matos, L, Vieira, M L C, Rollim, B, Fujita, L, Tufik, S, Poyares, D
Formato: Texto
Lenguaje:English
Publicado: BMJ Group 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2764351/
https://www.ncbi.nlm.nih.gov/pubmed/19643769
http://dx.doi.org/10.1136/hrt.2009.173625
_version_ 1782173074499567616
author Oliveira, W
Campos, O
Cintra, F
Matos, L
Vieira, M L C
Rollim, B
Fujita, L
Tufik, S
Poyares, D
author_facet Oliveira, W
Campos, O
Cintra, F
Matos, L
Vieira, M L C
Rollim, B
Fujita, L
Tufik, S
Poyares, D
author_sort Oliveira, W
collection PubMed
description BACKGROUND: Obstructive sleep apnoea (OSA) has been reported as a predictor of left ventricle (LV) diastolic dysfunction and left atrium (LA) remodelling. The aim of this study is to evaluate the impact of OSA treatment with a continuous positive airway pressure device (CPAP) on the LA volume and function, as well as on the LV diastolic function. METHODS: In total, 56 OSA patients were studied. All patients underwent real-time three-dimensional (RT3DE) and two-dimensional echocardiogram with tissue Doppler evaluation in order to estimate LA volumes, function and LV diastolic performance. A total of 30 patients with an apnoea-hypopnoea index greater than 20 were randomly selected to receive sham CPAP (n = 15) or effective CPAP (n = 15) for 24 weeks. They underwent echo examination on three different occasions: at baseline, after 12 weeks and 24 weeks of CPAP or sham CPAP. RESULTS: In the effective CPAP group we observed the following changes from the baseline to the 24-week echo evaluation: (a) a reduction in the E/E′ ratio (10.3 (1.9) to 7.9 (1.3), p = 0.03); (b) an increase in the LA passive emptying fraction (28.8% (11.9%) to 46.8% (9.3%), p = 0.01); and (c) a reduction in the LA active emptying fraction (42.7% (11.5%) to 25.7 (15.7), p<0.01). In the sham group, there were no changes from the baseline to the 24-week echo. We found a positive correlation between 24 week/baseline LA active emptying volume and 24 week/baseline E/E′ ratios (r = 0.40, p<0.05) and a negative correlation between 24 week/baseline LA passive emptying volume and 24 week/baseline E/E′ ratios (r = −0.53, p<0.05). No significant changes were found on LA total emptying fraction. CONCLUSION: CPAP improved LV diastolic function and LA passive emptying, but not LA structural variables in OSA patients. TRIAL REGISTRATION NUMBER: NCT00768807.
format Text
id pubmed-2764351
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BMJ Group
record_format MEDLINE/PubMed
spelling pubmed-27643512009-11-04 Impact of continuous positive airway pressure treatment on left atrial volume and function in patients with obstructive sleep apnoea assessed by real-time three-dimensional echocardiography Oliveira, W Campos, O Cintra, F Matos, L Vieira, M L C Rollim, B Fujita, L Tufik, S Poyares, D Heart Original Articles BACKGROUND: Obstructive sleep apnoea (OSA) has been reported as a predictor of left ventricle (LV) diastolic dysfunction and left atrium (LA) remodelling. The aim of this study is to evaluate the impact of OSA treatment with a continuous positive airway pressure device (CPAP) on the LA volume and function, as well as on the LV diastolic function. METHODS: In total, 56 OSA patients were studied. All patients underwent real-time three-dimensional (RT3DE) and two-dimensional echocardiogram with tissue Doppler evaluation in order to estimate LA volumes, function and LV diastolic performance. A total of 30 patients with an apnoea-hypopnoea index greater than 20 were randomly selected to receive sham CPAP (n = 15) or effective CPAP (n = 15) for 24 weeks. They underwent echo examination on three different occasions: at baseline, after 12 weeks and 24 weeks of CPAP or sham CPAP. RESULTS: In the effective CPAP group we observed the following changes from the baseline to the 24-week echo evaluation: (a) a reduction in the E/E′ ratio (10.3 (1.9) to 7.9 (1.3), p = 0.03); (b) an increase in the LA passive emptying fraction (28.8% (11.9%) to 46.8% (9.3%), p = 0.01); and (c) a reduction in the LA active emptying fraction (42.7% (11.5%) to 25.7 (15.7), p<0.01). In the sham group, there were no changes from the baseline to the 24-week echo. We found a positive correlation between 24 week/baseline LA active emptying volume and 24 week/baseline E/E′ ratios (r = 0.40, p<0.05) and a negative correlation between 24 week/baseline LA passive emptying volume and 24 week/baseline E/E′ ratios (r = −0.53, p<0.05). No significant changes were found on LA total emptying fraction. CONCLUSION: CPAP improved LV diastolic function and LA passive emptying, but not LA structural variables in OSA patients. TRIAL REGISTRATION NUMBER: NCT00768807. BMJ Group 2009-11-15 2009-07-29 /pmc/articles/PMC2764351/ /pubmed/19643769 http://dx.doi.org/10.1136/hrt.2009.173625 Text en © Oliveira et al 2009 http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Oliveira, W
Campos, O
Cintra, F
Matos, L
Vieira, M L C
Rollim, B
Fujita, L
Tufik, S
Poyares, D
Impact of continuous positive airway pressure treatment on left atrial volume and function in patients with obstructive sleep apnoea assessed by real-time three-dimensional echocardiography
title Impact of continuous positive airway pressure treatment on left atrial volume and function in patients with obstructive sleep apnoea assessed by real-time three-dimensional echocardiography
title_full Impact of continuous positive airway pressure treatment on left atrial volume and function in patients with obstructive sleep apnoea assessed by real-time three-dimensional echocardiography
title_fullStr Impact of continuous positive airway pressure treatment on left atrial volume and function in patients with obstructive sleep apnoea assessed by real-time three-dimensional echocardiography
title_full_unstemmed Impact of continuous positive airway pressure treatment on left atrial volume and function in patients with obstructive sleep apnoea assessed by real-time three-dimensional echocardiography
title_short Impact of continuous positive airway pressure treatment on left atrial volume and function in patients with obstructive sleep apnoea assessed by real-time three-dimensional echocardiography
title_sort impact of continuous positive airway pressure treatment on left atrial volume and function in patients with obstructive sleep apnoea assessed by real-time three-dimensional echocardiography
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2764351/
https://www.ncbi.nlm.nih.gov/pubmed/19643769
http://dx.doi.org/10.1136/hrt.2009.173625
work_keys_str_mv AT oliveiraw impactofcontinuouspositiveairwaypressuretreatmentonleftatrialvolumeandfunctioninpatientswithobstructivesleepapnoeaassessedbyrealtimethreedimensionalechocardiography
AT camposo impactofcontinuouspositiveairwaypressuretreatmentonleftatrialvolumeandfunctioninpatientswithobstructivesleepapnoeaassessedbyrealtimethreedimensionalechocardiography
AT cintraf impactofcontinuouspositiveairwaypressuretreatmentonleftatrialvolumeandfunctioninpatientswithobstructivesleepapnoeaassessedbyrealtimethreedimensionalechocardiography
AT matosl impactofcontinuouspositiveairwaypressuretreatmentonleftatrialvolumeandfunctioninpatientswithobstructivesleepapnoeaassessedbyrealtimethreedimensionalechocardiography
AT vieiramlc impactofcontinuouspositiveairwaypressuretreatmentonleftatrialvolumeandfunctioninpatientswithobstructivesleepapnoeaassessedbyrealtimethreedimensionalechocardiography
AT rollimb impactofcontinuouspositiveairwaypressuretreatmentonleftatrialvolumeandfunctioninpatientswithobstructivesleepapnoeaassessedbyrealtimethreedimensionalechocardiography
AT fujital impactofcontinuouspositiveairwaypressuretreatmentonleftatrialvolumeandfunctioninpatientswithobstructivesleepapnoeaassessedbyrealtimethreedimensionalechocardiography
AT tufiks impactofcontinuouspositiveairwaypressuretreatmentonleftatrialvolumeandfunctioninpatientswithobstructivesleepapnoeaassessedbyrealtimethreedimensionalechocardiography
AT poyaresd impactofcontinuouspositiveairwaypressuretreatmentonleftatrialvolumeandfunctioninpatientswithobstructivesleepapnoeaassessedbyrealtimethreedimensionalechocardiography