Management of a tibial periprosthetic fracture following revision knee arthroplasty using a pulsed electromagnetic field stimulation device: a case report
Periprosthetic fractures associated with total knee arthroplasty are rare but present a challenging problem particularly when associated with revision arthroplasty. Fractures around tibial stems are particularly difficult with no accepted technique in their management. This case describes a tibial p...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Cases Network Ltd
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2769467/ https://www.ncbi.nlm.nih.gov/pubmed/19918397 http://dx.doi.org/10.4076/1757-1626-2-8706 |
Sumario: | Periprosthetic fractures associated with total knee arthroplasty are rare but present a challenging problem particularly when associated with revision arthroplasty. Fractures around tibial stems are particularly difficult with no accepted technique in their management. This case describes a tibial periprosthetic fracture following a revision knee arthroplasty which was successfully managed with a Pulsed ElectroMagnetic Field bone stimulation device. We believe this to be first reported use of a bone stimulation device in this clinical environment. |
---|