Cargando…

The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography

BACKGROUND AND OBJECTIVES: The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT). SUBJECTS AND METHODS: In 20 patients (mean age, 50±12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitra...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Dong-Hyeon, Youn, Ho-Joong, Shim, Sung-Bo, Lee, Sun-Hee, Jung, Jung-Im, Jung, Seung-Eun, Choi, Yun-Seok, Park, Chul-Soo, Oh, Yong-Seog, Chung, Wook-Sung, Kim, Jae-Hyung
Formato: Texto
Lenguaje:English
Publicado: The Korean Society of Cardiology 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2771814/
https://www.ncbi.nlm.nih.gov/pubmed/19949605
http://dx.doi.org/10.4070/kcj.2009.39.4.157
_version_ 1782173763891101696
author Lee, Dong-Hyeon
Youn, Ho-Joong
Shim, Sung-Bo
Lee, Sun-Hee
Jung, Jung-Im
Jung, Seung-Eun
Choi, Yun-Seok
Park, Chul-Soo
Oh, Yong-Seog
Chung, Wook-Sung
Kim, Jae-Hyung
author_facet Lee, Dong-Hyeon
Youn, Ho-Joong
Shim, Sung-Bo
Lee, Sun-Hee
Jung, Jung-Im
Jung, Seung-Eun
Choi, Yun-Seok
Park, Chul-Soo
Oh, Yong-Seog
Chung, Wook-Sung
Kim, Jae-Hyung
author_sort Lee, Dong-Hyeon
collection PubMed
description BACKGROUND AND OBJECTIVES: The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT). SUBJECTS AND METHODS: In 20 patients (mean age, 50±12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitral valves) were evaluated using MDCT. We selected images vertical and parallel to the mechanical valve. The valve orifice area (OA) and valve length were determined by manual tracing and the opening and closing angles were measured using a protractor. The OA and length of the mechanical valves were compared with the manufacturer's values. RESULTS: The geometric orifice areas (GOAs) based on the manufacturer's values and the OAs determined by MDCT were 3.4±0.2 cm(2) and 3.4±0.3 cm(2) for the mitral valves and 2.1±0.3 cm(2) and 2.1±0.4 cm(2) for the aortic valves, respectively. The correlation coefficients between the OA measures were 0.433 for the mitral valves and 0.874 for the aortic valves (both p<0.001). The lengths based on the manufacturer's values and determined by MDCT were 29.3±1.99 mm and 29.6±1.65 mm for the mitral valves and 21.5±2.1 mm and 20.7±2.3 mm for the aortic valves, respectively. The correlation coefficients between the measures were 0.651 for the mitral valve and 0.846 for the aortic valve (both p<0.001). The opening and closing angles determined by MDCT were 10.9±0.6° and 131.1±3.2° for the mitral valves and 11.1±0.9° and 120.6±1.7° for the aortic valves, respectively. CONCLUSION: MDCT is an accurate modality with which to assess the function and morphology of bileaflet mechanical valves.
format Text
id pubmed-2771814
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher The Korean Society of Cardiology
record_format MEDLINE/PubMed
spelling pubmed-27718142009-11-30 The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography Lee, Dong-Hyeon Youn, Ho-Joong Shim, Sung-Bo Lee, Sun-Hee Jung, Jung-Im Jung, Seung-Eun Choi, Yun-Seok Park, Chul-Soo Oh, Yong-Seog Chung, Wook-Sung Kim, Jae-Hyung Korean Circ J Original Article BACKGROUND AND OBJECTIVES: The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT). SUBJECTS AND METHODS: In 20 patients (mean age, 50±12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitral valves) were evaluated using MDCT. We selected images vertical and parallel to the mechanical valve. The valve orifice area (OA) and valve length were determined by manual tracing and the opening and closing angles were measured using a protractor. The OA and length of the mechanical valves were compared with the manufacturer's values. RESULTS: The geometric orifice areas (GOAs) based on the manufacturer's values and the OAs determined by MDCT were 3.4±0.2 cm(2) and 3.4±0.3 cm(2) for the mitral valves and 2.1±0.3 cm(2) and 2.1±0.4 cm(2) for the aortic valves, respectively. The correlation coefficients between the OA measures were 0.433 for the mitral valves and 0.874 for the aortic valves (both p<0.001). The lengths based on the manufacturer's values and determined by MDCT were 29.3±1.99 mm and 29.6±1.65 mm for the mitral valves and 21.5±2.1 mm and 20.7±2.3 mm for the aortic valves, respectively. The correlation coefficients between the measures were 0.651 for the mitral valve and 0.846 for the aortic valve (both p<0.001). The opening and closing angles determined by MDCT were 10.9±0.6° and 131.1±3.2° for the mitral valves and 11.1±0.9° and 120.6±1.7° for the aortic valves, respectively. CONCLUSION: MDCT is an accurate modality with which to assess the function and morphology of bileaflet mechanical valves. The Korean Society of Cardiology 2009-04 2009-04-28 /pmc/articles/PMC2771814/ /pubmed/19949605 http://dx.doi.org/10.4070/kcj.2009.39.4.157 Text en Copyright © 2009 The Korean Society of Cardiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Dong-Hyeon
Youn, Ho-Joong
Shim, Sung-Bo
Lee, Sun-Hee
Jung, Jung-Im
Jung, Seung-Eun
Choi, Yun-Seok
Park, Chul-Soo
Oh, Yong-Seog
Chung, Wook-Sung
Kim, Jae-Hyung
The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography
title The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography
title_full The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography
title_fullStr The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography
title_full_unstemmed The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography
title_short The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography
title_sort measurement of opening angle and orifice area of a bileaflet mechanical valve using multidetector computed tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2771814/
https://www.ncbi.nlm.nih.gov/pubmed/19949605
http://dx.doi.org/10.4070/kcj.2009.39.4.157
work_keys_str_mv AT leedonghyeon themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT younhojoong themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT shimsungbo themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT leesunhee themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT jungjungim themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT jungseungeun themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT choiyunseok themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT parkchulsoo themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT ohyongseog themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT chungwooksung themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT kimjaehyung themeasurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT leedonghyeon measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT younhojoong measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT shimsungbo measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT leesunhee measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT jungjungim measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT jungseungeun measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT choiyunseok measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT parkchulsoo measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT ohyongseog measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT chungwooksung measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography
AT kimjaehyung measurementofopeningangleandorificeareaofabileafletmechanicalvalveusingmultidetectorcomputedtomography