Cargando…

Clinical implementation of dynamic intensity-modulated radiotherapy: Dosimetric aspects and initial experience

This paper describes the initial experience of quality assurance (QA) tests performed on the millennium multi-leaf collimator (mMLC) for clinical implementation of intensity-modulated radiotherapy (IMRT) using sliding window technique. The various QA tests verified the mechanical and dosimetric stab...

Descripción completa

Detalles Bibliográficos
Autores principales: Sivakumar, S. S., Krishnamurthy, K., Davis, C. A., Ravichandran, R., Kannadhasan, S., Biunkumar, J. P., El Ghamrawy, Kamal
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2772030/
https://www.ncbi.nlm.nih.gov/pubmed/19893693
http://dx.doi.org/10.4103/0971-6203.41195
_version_ 1782173797001986048
author Sivakumar, S. S.
Krishnamurthy, K.
Davis, C. A.
Ravichandran, R.
Kannadhasan, S.
Biunkumar, J. P.
El Ghamrawy, Kamal
author_facet Sivakumar, S. S.
Krishnamurthy, K.
Davis, C. A.
Ravichandran, R.
Kannadhasan, S.
Biunkumar, J. P.
El Ghamrawy, Kamal
author_sort Sivakumar, S. S.
collection PubMed
description This paper describes the initial experience of quality assurance (QA) tests performed on the millennium multi-leaf collimator (mMLC) for clinical implementation of intensity-modulated radiotherapy (IMRT) using sliding window technique. The various QA tests verified the mechanical and dosimetric stability of the mMLC of linear accelerator when operated in dynamic mode (dMLC). The mechanical QA tests also verified the positional accuracy and kinetic properties of the dMLC. The stability of dMLC was analyzed qualitatively and quantitatively using radiographic film and Omnipro IMRT software. The output stability, variation in output for different sweeping gap widths, and dosimetric leaf separation were measured. Dose delivery with IMRT was verified against the dose computed by the treatment planning system (TPS). Monitor units (MUs) calculated by the planning system for the IMRT were cross-checked with independent commercial dose management software. Visual inspection and qualitative analysis showed that the leaf positioning accuracy was well within the acceptable limits. Dosimetric QA tests confirmed the dosimetric stability of the mMLC in dynamic mode. The verification of MUs using commercial software confirmed the reliability of the IMRT planning system for dose computation. The dosimetric measurements validated the fractional dose delivery.
format Text
id pubmed-2772030
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-27720302009-11-05 Clinical implementation of dynamic intensity-modulated radiotherapy: Dosimetric aspects and initial experience Sivakumar, S. S. Krishnamurthy, K. Davis, C. A. Ravichandran, R. Kannadhasan, S. Biunkumar, J. P. El Ghamrawy, Kamal J Med Phys Technical Note This paper describes the initial experience of quality assurance (QA) tests performed on the millennium multi-leaf collimator (mMLC) for clinical implementation of intensity-modulated radiotherapy (IMRT) using sliding window technique. The various QA tests verified the mechanical and dosimetric stability of the mMLC of linear accelerator when operated in dynamic mode (dMLC). The mechanical QA tests also verified the positional accuracy and kinetic properties of the dMLC. The stability of dMLC was analyzed qualitatively and quantitatively using radiographic film and Omnipro IMRT software. The output stability, variation in output for different sweeping gap widths, and dosimetric leaf separation were measured. Dose delivery with IMRT was verified against the dose computed by the treatment planning system (TPS). Monitor units (MUs) calculated by the planning system for the IMRT were cross-checked with independent commercial dose management software. Visual inspection and qualitative analysis showed that the leaf positioning accuracy was well within the acceptable limits. Dosimetric QA tests confirmed the dosimetric stability of the mMLC in dynamic mode. The verification of MUs using commercial software confirmed the reliability of the IMRT planning system for dose computation. The dosimetric measurements validated the fractional dose delivery. Medknow Publications 2008 /pmc/articles/PMC2772030/ /pubmed/19893693 http://dx.doi.org/10.4103/0971-6203.41195 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Sivakumar, S. S.
Krishnamurthy, K.
Davis, C. A.
Ravichandran, R.
Kannadhasan, S.
Biunkumar, J. P.
El Ghamrawy, Kamal
Clinical implementation of dynamic intensity-modulated radiotherapy: Dosimetric aspects and initial experience
title Clinical implementation of dynamic intensity-modulated radiotherapy: Dosimetric aspects and initial experience
title_full Clinical implementation of dynamic intensity-modulated radiotherapy: Dosimetric aspects and initial experience
title_fullStr Clinical implementation of dynamic intensity-modulated radiotherapy: Dosimetric aspects and initial experience
title_full_unstemmed Clinical implementation of dynamic intensity-modulated radiotherapy: Dosimetric aspects and initial experience
title_short Clinical implementation of dynamic intensity-modulated radiotherapy: Dosimetric aspects and initial experience
title_sort clinical implementation of dynamic intensity-modulated radiotherapy: dosimetric aspects and initial experience
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2772030/
https://www.ncbi.nlm.nih.gov/pubmed/19893693
http://dx.doi.org/10.4103/0971-6203.41195
work_keys_str_mv AT sivakumarss clinicalimplementationofdynamicintensitymodulatedradiotherapydosimetricaspectsandinitialexperience
AT krishnamurthyk clinicalimplementationofdynamicintensitymodulatedradiotherapydosimetricaspectsandinitialexperience
AT davisca clinicalimplementationofdynamicintensitymodulatedradiotherapydosimetricaspectsandinitialexperience
AT ravichandranr clinicalimplementationofdynamicintensitymodulatedradiotherapydosimetricaspectsandinitialexperience
AT kannadhasans clinicalimplementationofdynamicintensitymodulatedradiotherapydosimetricaspectsandinitialexperience
AT biunkumarjp clinicalimplementationofdynamicintensitymodulatedradiotherapydosimetricaspectsandinitialexperience
AT elghamrawykamal clinicalimplementationofdynamicintensitymodulatedradiotherapydosimetricaspectsandinitialexperience